Files
fulpstation/code/ATMOSPHERICS/components/binary_devices/passive_gate.dm
2016-01-01 17:47:44 -06:00

181 lines
5.2 KiB
Plaintext

/*
Passive gate is similar to the regular pump except:
* It doesn't require power
* Can not transfer low pressure to higher pressure (so it's more like a valve where you can control the flow)
*/
/obj/machinery/atmospherics/components/binary/passive_gate
icon_state = "passgate_map"
name = "passive gate"
desc = "A one-way air valve that does not require power"
can_unwrench = 1
var/on = 0
var/target_pressure = ONE_ATMOSPHERE
var/frequency = 0
var/id = null
var/datum/radio_frequency/radio_connection
/obj/machinery/atmospherics/components/binary/passive_gate/Destroy()
if(SSradio)
SSradio.remove_object(src,frequency)
return ..()
/obj/machinery/atmospherics/components/binary/passive_gate/update_icon_nopipes()
if(!on)
icon_state = "passgate_off"
overlays.Cut()
return
overlays += getpipeimage('icons/obj/atmospherics/components/binary_devices.dmi', "passgate_on")
/obj/machinery/atmospherics/components/binary/passive_gate/process_atmos()
..()
if(!on)
return 0
var/datum/gas_mixture/air1 = AIR1
var/datum/gas_mixture/air2 = AIR2
var/output_starting_pressure = air2.return_pressure()
var/input_starting_pressure = air1.return_pressure()
if(output_starting_pressure >= min(target_pressure,input_starting_pressure-10))
//No need to pump gas if target is already reached or input pressure is too low
//Need at least 10 KPa difference to overcome friction in the mechanism
return 1
//Calculate necessary moles to transfer using PV = nRT
if((air1.total_moles() > 0) && (air1.temperature>0))
var/pressure_delta = min(target_pressure - output_starting_pressure, (input_starting_pressure - output_starting_pressure)/2)
//Can not have a pressure delta that would cause output_pressure > input_pressure
var/transfer_moles = pressure_delta*air2.volume/(air1.temperature * R_IDEAL_GAS_EQUATION)
//Actually transfer the gas
var/datum/gas_mixture/removed = air1.remove(transfer_moles)
air2.merge(removed)
update_parents()
//Radio remote control
/obj/machinery/atmospherics/components/binary/passive_gate/proc/set_frequency(new_frequency)
SSradio.remove_object(src, frequency)
frequency = new_frequency
if(frequency)
radio_connection = SSradio.add_object(src, frequency, filter = RADIO_ATMOSIA)
/obj/machinery/atmospherics/components/binary/passive_gate/proc/broadcast_status()
if(!radio_connection)
return 0
var/datum/signal/signal = new
signal.transmission_method = 1 //radio signal
signal.source = src
signal.data = list(
"tag" = id,
"device" = "AGP",
"power" = on,
"target_output" = target_pressure,
"sigtype" = "status"
)
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
return 1
/obj/machinery/atmospherics/components/binary/passive_gate/interact(mob/user)
if(stat & (BROKEN|NOPOWER)) return
ui_interact(user)
/obj/machinery/atmospherics/components/binary/passive_gate/ui_interact(mob/user, ui_key = "main", datum/tgui/ui = null, force_open = 0)
ui = SStgui.try_update_ui(user, src, ui_key, ui, force_open = force_open)
if (!ui)
ui = new(user, src, ui_key, "atmos_pump", name, 400, 115)
ui.open()
/obj/machinery/atmospherics/components/binary/passive_gate/get_ui_data()
var/data = list()
data["on"] = on
data["set_pressure"] = round(target_pressure)
data["max_pressure"] = round(MAX_OUTPUT_PRESSURE)
return data
/obj/machinery/atmospherics/components/binary/passive_gate/atmosinit()
..()
if(frequency)
set_frequency(frequency)
/obj/machinery/atmospherics/components/binary/passive_gate/receive_signal(datum/signal/signal)
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
return 0
var/old_on = on //for logging
if("power" in signal.data)
on = text2num(signal.data["power"])
if("power_toggle" in signal.data)
on = !on
if("set_output_pressure" in signal.data)
target_pressure = Clamp(text2num(signal.data["set_output_pressure"]),0,ONE_ATMOSPHERE*50)
if(on != old_on)
investigate_log("was turned [on ? "on" : "off"] by a remote signal", "atmos")
if("status" in signal.data)
spawn(2)
broadcast_status()
return //do not update_icon
spawn(2)
broadcast_status()
update_icon()
return
/obj/machinery/atmospherics/components/binary/passive_gate/attack_hand(mob/user)
if(..() || !user)
return
interact(user)
/obj/machinery/atmospherics/components/binary/passive_gate/ui_act(action, params)
if(..())
return
switch(action)
if("power")
on = !on
investigate_log("was turned [on ? "on" : "off"] by [key_name(usr)]", "atmos")
if("pressure")
switch(params["pressure"])
if ("max")
target_pressure = MAX_OUTPUT_PRESSURE
if ("custom")
target_pressure = max(0, min(MAX_OUTPUT_PRESSURE, safe_input("Pressure control", "Enter new output pressure (0-[MAX_OUTPUT_PRESSURE] kPa)", target_pressure)))
investigate_log("was set to [target_pressure] kPa by [key_name(usr)]", "atmos")
update_icon()
return 1
/obj/machinery/atmospherics/components/binary/passive_gate/power_change()
..()
update_icon()
/obj/machinery/atmospherics/components/binary/passive_gate/attackby(obj/item/weapon/W, mob/user, params)
if (!istype(W, /obj/item/weapon/wrench))
return ..()
if (on)
user << "<span class='warning'>You cannot unwrench this [src], turn it off first!</span>"
return 1
return ..()