Files
2020-02-19 19:48:29 -08:00

371 lines
9.8 KiB
Plaintext

// the SMES
// stores power
#define SMESMAXCHARGELEVEL 200000
#define SMESMAXOUTPUT 200000
/obj/machinery/power/smes/magical
name = "magical power storage unit"
desc = "A high-capacity superconducting magnetic energy storage (SMES) unit. Magically produces power, using magic."
process()
capacity = INFINITY
charge = INFINITY
..()
/obj/machinery/power/smes
name = "power storage unit"
desc = "A high-capacity superconducting magnetic energy storage (SMES) unit."
icon_state = "smes"
density = 1
anchored = 1
var/output = 30000
var/lastout = 0
var/loaddemand = 0
var/capacity = 1e8
var/charge = 2e7
var/charging = 0
var/chargemode = 1
var/chargecount = 0
var/chargelevel = 30000
var/lastexcess = 0
var/online = 1
var/n_tag = null
var/obj/machinery/power/terminal/terminal = null
get_desc()
. = {"It's [online ? "on" : "off"]line. [charging ? "It's charging, and it" : "It"] looks about [round(charge / capacity * 100, 20)]% full."}
/obj/machinery/power/smes/construction
New(var/turf/iloc, var/idir = 2)
if (!isturf(iloc))
qdel(src)
dir = idir
var/turf/Q = get_step(iloc, idir)
if (!Q)
qdel(src)
var/obj/machinery/power/terminal/term = new /obj/machinery/power/terminal(Q)
term.dir = get_dir(Q, iloc)
..()
/obj/machinery/power/smes/emp_act()
..()
src.online = 0
src.charging = 0
src.output = 0
src.charge -= 1e6
if (src.charge < 0)
src.charge = 0
SPAWN_DBG(10 SECONDS)
src.output = initial(src.output)
src.charging = initial(src.charging)
src.online = initial(src.online)
return
/obj/machinery/power/smes/New()
..()
SPAWN_DBG(5 DECI SECONDS)
dir_loop:
for(var/d in cardinal)
var/turf/T = get_step(src, d)
for(var/obj/machinery/power/terminal/term in T)
if (term && term.dir == turn(d, 180))
terminal = term
break dir_loop
if (!terminal)
status |= BROKEN
return
terminal.master = src
updateicon()
/obj/machinery/power/smes/proc/updateicon()
if (status & BROKEN)
ClearAllOverlays()
return
var/image/I = SafeGetOverlayImage("operating", 'icons/obj/power.dmi', "smes-op[online]")
UpdateOverlays(I, "operating")
I = SafeGetOverlayImage("chargemode",'icons/obj/power.dmi', "smes-oc1")
if (charging)
I.icon_state = "smes-oc1"
else if (chargemode)
I.icon_state = "smes-oc0"
else
I = null
UpdateOverlays(I, "chargemode", 0, 1)
var/clevel = chargedisplay()
if (clevel>0)
I = SafeGetOverlayImage("chargedisp",'icons/obj/power.dmi',"smes-og[clevel]")
UpdateOverlays(I, "chargedisp")
/obj/machinery/power/smes/proc/chargedisplay()
return round(5.5*charge/capacity)
/obj/machinery/power/smes/process()
if (status & BROKEN)
return
//store machine state to see if we need to update the icon overlays
var/last_disp = chargedisplay()
var/last_chrg = charging
var/last_onln = online
// Had to revert a hack here that caused SMES to continue charging despite insufficient power coming in on the input (terminal) side.
if (terminal)
var/excess = terminal.surplus()
var/load = 0
if (charging)
if (excess >= 0) // if there's power available, try to charge
load = min(capacity-charge, chargelevel) // charge at set rate, limited to spare capacity
charge += load // increase the charge
add_load(load) // add the load to the terminal side network
else // if not enough capcity
charging = 0 // stop charging
chargecount = 0
else if (chargemode)
if (chargecount > 2)
charging = 1
chargecount = 0
else if (excess >= chargelevel)
chargecount++
else
chargecount = 0
lastexcess = load + excess
if (online) // if outputting
if (prob(5))
SPAWN_DBG(1 DECI SECOND)
playsound(src.loc, pick(ambience_power), 60, 1)
lastout = min(charge, output) //limit output to that stored
charge -= lastout // reduce the storage (may be recovered in /restore() if excessive)
add_avail(lastout) // add output to powernet (smes side)
if (charge < 0.0001)
online = 0 // stop output if charge falls to zero
// only update icon if state changed
if (last_disp != chargedisplay() || last_chrg != charging || last_onln != online)
updateicon()
for(var/mob/M in viewers(1, src))
if ((M.client && M.machine == src))
src.interact(M)
AutoUpdateAI(src)
// called after all power processes are finished
// restores charge level to smes if there was excess this ptick
/obj/machinery/power/smes/proc/restore()
if (status & BROKEN)
return
if (!online)
loaddemand = 0
return
var/excess = powernet.netexcess // this was how much wasn't used on the network last ptick, minus any removed by other SMESes
excess = min(lastout, excess) // clamp it to how much was actually output by this SMES last ptick
excess = min(capacity-charge, excess) // for safety, also limit recharge by space capacity of SMES (shouldn't happen)
// now recharge this amount
var/clev = chargedisplay()
charge += excess
powernet.netexcess -= excess // remove the excess from the powernet, so later SMESes don't try to use it
loaddemand = lastout - excess
if (clev != chargedisplay())
updateicon()
///obj/machinery/power/smes/add_avail(var/amount)
// if (terminal && terminal.powernet)
// terminal.powernet.newavail += amount
/obj/machinery/power/smes/add_load(var/amount)
if (terminal && terminal.powernet)
terminal.powernet.newload += amount
/obj/machinery/power/smes/attack_ai(mob/user)
add_fingerprint(user)
if (status & BROKEN) return
interact(user)
/obj/machinery/power/smes/attack_hand(mob/user)
add_fingerprint(user)
if (status & BROKEN) return
interact(user)
/obj/machinery/power/smes/proc/interact(mob/user)
if ( (get_dist(src, user) > 1 ))
if (!isAI(user) && !issilicon(user))
user.machine = null
user.Browse(null, "window=smes")
return
user.machine = src
// @todo fix this later
var/t = {"
<title>SMES Status [n_tag ? " - [n_tag]" : null]</title>
<style type="text/css">
h3, h4 {
margin: 0;
}
#powerMenu > div {
box-sizing: border-box;
}
.bar {
height: 8px;
max-height: 8px;
background: #363;
border: 1px solid white;
padding: 1px;
position: relative;
margin: 0.25em 0;
}
.bar .inner {
height: 100%;
margin: 0;
padding: 0;
background: #4e4;
}
.bar .marker {
position: absolute;
top: 0px;
width: 1px;
margin-left: -1px;
height: 40%;
background: white;
border: 1px solid black;
border-top: none;
}
p {
margin: 0.25em 0;
}
</style>
<div id="#powerMenu">
<h3 style="text-align: center;">SMES Power Storage Unit [n_tag ? "- [n_tag]" : null]</h3>
<br>
<strong>Stored Charge: [round(100.0*charge/capacity, 0.1)]%</strong> <em>([charging ? "Charging" : ((chargecount > 0) ? "Preparing to charge..." : "Not Charging")])</em>
<div class='bar'><div class='inner' style="width: [round(100 * (charge / capacity), 0.01)]%;"></div></div>
<br>
<strong>Charging:</strong> [chargemode ? "<b>Enabled</b> (<a href='?src=\ref[src];cmode=1'>Disable</a>)" : "<b>Disabled</b> (<a href='?src=\ref[src];cmode=1'>Enable</a>)"]
<br><strong>Input level:</strong> <a href='?src=\ref[src];input=set'>[chargelevel]</a> (<a href='?src=\ref[src];input=min'>Min</a> &middot; <a href='?src=\ref[src];input=max'>Max</a>)
<div class='bar-outer'><div class='bar'><div class='inner' style="width: [max(0, min(100, round(100 * (lastexcess / SMESMAXCHARGELEVEL), 0.01)))]%;"></div><div class='marker' style="left: [round(100 * (chargelevel / SMESMAXCHARGELEVEL), 0.01)]%;"></div></div>
<strong>Available:</strong> [round(lastexcess)] W
<br>
<br>
<strong>Output:</strong> [online ? "<b>Enabled</b> (<a href='?src=\ref[src];online=1'>Disable</a>)" : "<b>Disabled</b> (<a href='?src=\ref[src];online=1'>Enable</a>)"]
<br><strong>Output level:</strong> <a href='?src=\ref[src];output=set'>[output]</a> (<a href='?src=\ref[src];output=min'>Min</a> &middot; <a href='?src=\ref[src];output=max'>Max</a>)
<div class='bar'><div class='inner' style="width: [min(100, round(100 * (loaddemand / SMESMAXOUTPUT), 0.01))]%;"></div><div class='marker' style="left: [round(100 * (output / SMESMAXCHARGELEVEL), 0.01)]%;"></div></div>
<strong>Current load:</strong> [round(loaddemand)] W
</div>
"}
user.Browse(t, "window=smes;size=400x340")
onclose(user, "smes")
return
/obj/machinery/power/smes/Topic(href, href_list)
..()
if (usr.stat || usr.restrained() )
return
if (( usr.machine==src && ((get_dist(src, usr) <= 1) && istype(src.loc, /turf))) || (isAI(usr) || issilicon(usr)))
if (href_list["close"])
usr.Browse(null, "window=smes")
usr.machine = null
return
else if ( href_list["cmode"] )
chargemode = !chargemode
if (!chargemode)
charging = 0
updateicon()
else if ( href_list["online"] )
online = !online
updateicon()
else if (href_list["input"])
switch (href_list["input"])
if ("min")
chargelevel = 0
if ("max")
chargelevel = SMESMAXCHARGELEVEL
if ("set")
var/newnum = input(usr, "New target charge level? 0 to [SMESMAXCHARGELEVEL].", "SMES Config", chargelevel) as null|num
if (newnum)
chargelevel = newnum
chargelevel = max(0, min(SMESMAXCHARGELEVEL, chargelevel)) // clamp to range
else if (href_list["output"])
switch (href_list["output"])
if ("min")
output = 0
if ("max")
output = SMESMAXOUTPUT
if ("set")
var/newnum = input(usr, "New output level? 0 to [SMESMAXOUTPUT].", "SMES Config", output) as null|num
if (newnum)
output = newnum
output = max(0, min(SMESMAXOUTPUT, output)) // clamp to range
src.updateUsrDialog()
else
usr.Browse(null, "window=smes")
usr.machine = null
return
/proc/rate_control(var/S, var/V, var/C, var/Min=1, var/Max=5, var/Limit=null)
var/href = "<A href='?src=\ref[S];rate control=1;[V]"
var/rate = "[href]=-[Max]'>-</A>[href]=-[Min]'>-</A> [(C?C : 0)] [href]=[Min]'>+</A>[href]=[Max]'>+</A>"
if (Limit) return "[href]=-[Limit]'>-</A>"+rate+"[href]=[Limit]'>+</A>"
return rate
#undef SMESMAXCHARGELEVEL