Standardize radio ID tags (id -> id_tag). Fixes multitool runtimes.
This commit is contained in:
@@ -21,8 +21,8 @@
|
||||
if(href_list["set_subject"])
|
||||
var/list/valves=list()
|
||||
for(var/obj/machinery/atmospherics/valve/digital/V in machines)
|
||||
if(!isnull(V.id) && V.frequency == parent.frequency)
|
||||
valves|=V.id
|
||||
if(!isnull(V.id_tag) && V.frequency == parent.frequency)
|
||||
valves|=V.id_tag
|
||||
valve = input("Select a valve:", "Sensor Data", valve) as null|anything in valves
|
||||
parent.updateUsrDialog()
|
||||
return 1
|
||||
@@ -23,8 +23,8 @@
|
||||
if(href_list["set_injector"])
|
||||
var/list/injector_names=list()
|
||||
for(var/obj/machinery/atmospherics/unary/outlet_injector/I in machines)
|
||||
if(!isnull(I.id) && I.frequency == parent.frequency)
|
||||
injector_names|=I.id
|
||||
if(!isnull(I.id_tag) && I.frequency == parent.frequency)
|
||||
injector_names|=I.id_tag
|
||||
injector = input("Select an injector:", "Sensor Data", injector) as null|anything in injector_names
|
||||
parent.updateUsrDialog()
|
||||
return 1
|
||||
@@ -50,8 +50,8 @@
|
||||
if(href_list["set_injector"])
|
||||
var/list/injector_names=list()
|
||||
for(var/obj/machinery/atmospherics/unary/outlet_injector/I in machines)
|
||||
if(!isnull(I.id) && I.frequency == parent.frequency)
|
||||
injector_names|=I.id
|
||||
if(!isnull(I.id_tag) && I.frequency == parent.frequency)
|
||||
injector_names|=I.id_tag
|
||||
injector = input("Select an injector:", "Sensor Data", injector) as null|anything in injector_names
|
||||
parent.updateUsrDialog()
|
||||
return 1
|
||||
@@ -29,8 +29,8 @@
|
||||
if(!isnull(I.id_tag) && I.frequency == parent.frequency)
|
||||
injector_names|=I.id_tag
|
||||
for(var/obj/machinery/atmospherics/binary/dp_vent_pump/I in machines)
|
||||
if(!isnull(I.id) && I.frequency == parent.frequency)
|
||||
injector_names|=I.id
|
||||
if(!isnull(I.id_tag) && I.frequency == parent.frequency)
|
||||
injector_names|=I.id_tag
|
||||
vent_pump = input("Select a vent:", "Vent Pumps", vent_pump) as null|anything in injector_names
|
||||
parent.updateUsrDialog()
|
||||
return 1
|
||||
@@ -62,8 +62,8 @@
|
||||
if(!isnull(I.id_tag) && I.frequency == parent.frequency)
|
||||
injector_names|=I.id_tag
|
||||
for(var/obj/machinery/atmospherics/binary/dp_vent_pump/I in machines)
|
||||
if(!isnull(I.id) && I.frequency == parent.frequency)
|
||||
injector_names|=I.id
|
||||
if(!isnull(I.id_tag) && I.frequency == parent.frequency)
|
||||
injector_names|=I.id_tag
|
||||
vent_pump = input("Select a vent:", "Vent Pumps", vent_pump) as null|anything in injector_names
|
||||
parent.updateUsrDialog()
|
||||
return 1
|
||||
Reference in New Issue
Block a user