/obj/machinery/atmospherics/binary/dp_vent_pump icon = 'icons/obj/atmospherics/dp_vent_pump.dmi' icon_state = "off" //node2 is output port //node1 is input port name = "Dual Port Air Vent" desc = "Has a valve and pump attached to it. There are two ports." level = 1 var/on = 0 var/pump_direction = 1 //0 = siphoning, 1 = releasing var/external_pressure_bound = ONE_ATMOSPHERE var/input_pressure_min = 0 var/output_pressure_max = 0 var/pressure_checks = 1 //1: Do not pass external_pressure_bound //2: Do not pass input_pressure_min //4: Do not pass output_pressure_max var/frequency = 0 var/id_tag = null var/datum/radio_frequency/radio_connection machine_flags = MULTITOOL_MENU /obj/machinery/atmospherics/binary/dp_vent_pump/high_volume name = "Large Dual Port Air Vent" /obj/machinery/atmospherics/binary/dp_vent_pump/high_volume/New() ..() air1.volume = 2500 air2.volume = 2500 /obj/machinery/atmospherics/binary/dp_vent_pump/update_icon() if(on) if(pump_direction) icon_state = "[level == 1 && istype(loc, /turf/simulated) ? "h" : "" ]out" else icon_state = "[level == 1 && istype(loc, /turf/simulated) ? "h" : "" ]in" else icon_state = "[level == 1 && istype(loc, /turf/simulated) ? "h" : "" ]off" on = 0 return /obj/machinery/atmospherics/binary/dp_vent_pump/hide(var/i) //to make the little pipe section invisible, the icon changes. if(on) if(pump_direction) icon_state = "[i == 1 && istype(loc, /turf/simulated) ? "h" : "" ]out" else icon_state = "[i == 1 && istype(loc, /turf/simulated) ? "h" : "" ]in" else icon_state = "[i == 1 && istype(loc, /turf/simulated) ? "h" : "" ]off" on = 0 return /obj/machinery/atmospherics/binary/dp_vent_pump/multitool_menu(var/mob/user,var/obj/item/device/multitool/P) return {" "} /obj/machinery/atmospherics/binary/dp_vent_pump/process() . = ..() if(!on) return var/datum/gas_mixture/environment = loc.return_air() var/environment_pressure = environment.return_pressure() if(pump_direction) //input -> external var/pressure_delta = 10000 if(pressure_checks&1) pressure_delta = min(pressure_delta, (external_pressure_bound - environment_pressure)) if(pressure_checks&2) pressure_delta = min(pressure_delta, (air1.return_pressure() - input_pressure_min)) if(pressure_delta > 0) if(air1.temperature > 0) var/transfer_moles = pressure_delta*environment.volume/(air1.temperature * R_IDEAL_GAS_EQUATION) var/datum/gas_mixture/removed = air1.remove(transfer_moles) loc.assume_air(removed) if(network1) network1.update = 1 else //external -> output var/pressure_delta = 10000 if(pressure_checks&1) pressure_delta = min(pressure_delta, (environment_pressure - external_pressure_bound)) if(pressure_checks&4) pressure_delta = min(pressure_delta, (output_pressure_max - air2.return_pressure())) if(pressure_delta > 0) if(environment.temperature > 0) var/transfer_moles = pressure_delta*air2.volume/(environment.temperature * R_IDEAL_GAS_EQUATION) var/datum/gas_mixture/removed = loc.remove_air(transfer_moles) air2.merge(removed) if(network2) network2.update = 1 return 1 //Radio remote control /obj/machinery/atmospherics/binary/dp_vent_pump/proc/set_frequency(new_frequency) radio_controller.remove_object(src, frequency) frequency = new_frequency if(frequency) radio_connection = radio_controller.add_object(src, frequency, filter = RADIO_ATMOSIA) /obj/machinery/atmospherics/binary/dp_vent_pump/proc/broadcast_status() if(!radio_connection) return 0 var/datum/signal/signal = getFromPool(/datum/signal) signal.transmission_method = 1 //radio signal signal.source = src signal.data = list( "tag" = id_tag, "device" = "ADVP", "power" = on, "direction" = pump_direction?("release"):("siphon"), "checks" = pressure_checks, "input" = input_pressure_min, "output" = output_pressure_max, "external" = external_pressure_bound, "sigtype" = "status" ) radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA) return 1 /obj/machinery/atmospherics/binary/dp_vent_pump/initialize() ..() if(frequency) set_frequency(frequency) /obj/machinery/atmospherics/binary/dp_vent_pump/receive_signal(datum/signal/signal) if(!signal.data["tag"] || (signal.data["tag"] != id_tag) || (signal.data["sigtype"]!="command")) return 0 var/handled=0 if("power" in signal.data) on = text2num(signal.data["power"]) handled=1 if("power_toggle" in signal.data) on = !on handled=1 if("direction" in signal.data) pump_direction = text2num(signal.data["direction"]) handled=1 if("checks" in signal.data) pressure_checks = text2num(signal.data["checks"]) handled=1 if("purge" in signal.data) pressure_checks &= ~1 pump_direction = 0 handled=1 if("stabilize" in signal.data) pressure_checks |= 1 pump_direction = 1 handled=1 if("set_input_pressure" in signal.data) input_pressure_min = Clamp(text2num(signal.data["set_input_pressure"]), 0, ONE_ATMOSPHERE * 50) handled = 1 if("set_output_pressure" in signal.data) output_pressure_max = Clamp(text2num(signal.data["set_output_pressure"]), 0, ONE_ATMOSPHERE * 50) handled = 1 if("set_external_pressure" in signal.data) external_pressure_bound = Clamp(text2num(signal.data["set_external_pressure"]), 0, ONE_ATMOSPHERE * 50) handled = 1 if("status" in signal.data) spawn(2) broadcast_status() return //do not update_icon if(!handled) testing("\[[world.timeofday]\]: dp_vent_pump/receive_signal: unknown command \n[signal.debug_print()]") spawn(2) broadcast_status() update_icon() /obj/machinery/atmospherics/binary/dp_vent_pump/attackby(var/obj/item/W as obj, var/mob/user as mob) return ..() /obj/machinery/atmospherics/binary/dp_vent_pump/interact(var/mob/user) update_multitool_menu(user) /obj/machinery/atmospherics/binary/dp_vent_pump/canClone(var/obj/O) return istype(O, /obj/machinery/atmospherics/binary/dp_vent_pump) /obj/machinery/atmospherics/binary/dp_vent_pump/clone(var/obj/machinery/atmospherics/binary/dp_vent_pump/O) id_tag = O.id_tag set_frequency(O.frequency) return 1