/obj/machinery/atmospherics/unary/vent_pump icon = 'icons/obj/atmospherics/vent_pump.dmi' icon_state = "hoff" name = "Air Vent" desc = "Has a valve and pump attached to it" use_power = 1 level = 1 var/area_uid var/id_tag = null var/on = 0 var/pump_direction = 1 //0 = siphoning, 1 = releasing var/external_pressure_bound = ONE_ATMOSPHERE var/internal_pressure_bound = 0 var/pressure_checks = 1 //1: Do not pass external_pressure_bound //2: Do not pass internal_pressure_bound //3: Do not pass either var/welded = 0 // Added for aliens -- TLE var/canSpawnMice = 1 // Set to 0 to prevent spawning of mice. var/frequency = 1439 var/datum/radio_frequency/radio_connection var/radio_filter_out var/radio_filter_in machine_flags = MULTITOOL_MENU starting_volume = 400 // Previously 200 /obj/machinery/atmospherics/unary/vent_pump/on on = 1 icon_state = "hout" /obj/machinery/atmospherics/unary/vent_pump/siphon pump_direction = 0 icon_state = "hoff" /obj/machinery/atmospherics/unary/vent_pump/siphon/on on = 1 icon_state = "hin" /obj/machinery/atmospherics/unary/vent_pump/New() ..() area_uid = areaMaster.uid if (!id_tag) assign_uid() id_tag = num2text(uid) if(ticker && ticker.current_state == 3)//if the game is running //src.initialize() src.broadcast_status() /obj/machinery/atmospherics/unary/vent_pump/high_volume name = "Large Air Vent" power_channel = EQUIP /obj/machinery/atmospherics/unary/vent_pump/high_volume/New() ..() air_contents.volume = 1000 /obj/machinery/atmospherics/unary/vent_pump/update_icon() if(welded) icon_state = "hweld" return if(on && !(stat & (NOPOWER|BROKEN))) if(pump_direction) icon_state = "hout" else icon_state = "hin" else icon_state = "hoff" ..() if (istype(loc, /turf/simulated/floor) && node) var/turf/simulated/floor/floor = loc if(floor.floor_tile && node.alpha == 128) underlays.Cut() return /obj/machinery/atmospherics/unary/vent_pump/process() . = ..() CHECK_DISABLED(vents) if (!node) return // Turning off the vent is a PITA. - N3X if(stat & (NOPOWER|BROKEN)) return //on = 0 //broadcast_status() // from now air alarm/control computer should request update purposely --rastaf0 if(!on) return if(welded) return // New GC does this sometimes if(!loc) return var/datum/gas_mixture/environment = loc.return_air() var/environment_pressure = environment.return_pressure() if(pump_direction) //internal -> external var/pressure_delta = 10000 if(pressure_checks&1) pressure_delta = min(pressure_delta, (external_pressure_bound - environment_pressure)) if(pressure_checks&2) pressure_delta = min(pressure_delta, (air_contents.return_pressure() - internal_pressure_bound)) if(pressure_delta > 0.1) if(air_contents.temperature > 0) var/transfer_moles = pressure_delta*environment.volume/(air_contents.temperature * R_IDEAL_GAS_EQUATION) var/datum/gas_mixture/removed = air_contents.remove(transfer_moles) loc.assume_air(removed) if(network) network.update = 1 else //external -> internal var/pressure_delta = 10000 if(pressure_checks&1) pressure_delta = min(pressure_delta, (environment_pressure - external_pressure_bound)) if(pressure_checks&2) pressure_delta = min(pressure_delta, (internal_pressure_bound - air_contents.return_pressure())) if(pressure_delta > 0.1) if(environment.temperature > 0) var/transfer_moles = pressure_delta*air_contents.volume/(environment.temperature * R_IDEAL_GAS_EQUATION) var/datum/gas_mixture/removed = loc.remove_air(transfer_moles) if (isnull(removed)) //in space return air_contents.merge(removed) if(network) network.update = 1 return 1 //Radio remote control /obj/machinery/atmospherics/unary/vent_pump/proc/set_frequency(new_frequency) radio_controller.remove_object(src, frequency) frequency = new_frequency if(frequency) radio_connection = radio_controller.add_object(src, frequency,radio_filter_in) if(frequency != 1439) areaMaster.air_vent_info -= id_tag areaMaster.air_vent_names -= id_tag name = "Vent Pump" else broadcast_status() /obj/machinery/atmospherics/unary/vent_pump/buildFrom(var/mob/usr,var/obj/item/pipe/pipe) ..() src.broadcast_status() return 1 /obj/machinery/atmospherics/unary/vent_pump/proc/broadcast_status() if(!radio_connection) return 0 var/datum/signal/signal = getFromPool(/datum/signal) signal.transmission_method = 1 //radio signal signal.source = src signal.data = list( "area" = src.area_uid, "tag" = src.id_tag, "device" = "AVP", "power" = on, "direction" = pump_direction?("release"):("siphon"), "checks" = pressure_checks, "internal" = internal_pressure_bound, "external" = external_pressure_bound, "timestamp" = world.time, "sigtype" = "status" ) if(frequency == 1439) if(!areaMaster.air_vent_names[id_tag]) var/new_name = "[areaMaster.name] Vent Pump #[areaMaster.air_vent_names.len+1]" areaMaster.air_vent_names[id_tag] = new_name name = new_name areaMaster.air_vent_info[id_tag] = signal.data radio_connection.post_signal(src, signal, radio_filter_out) return 1 /obj/machinery/atmospherics/unary/vent_pump/initialize() ..() //some vents work his own spesial way radio_filter_in = frequency==1439?(RADIO_FROM_AIRALARM):null radio_filter_out = frequency==1439?(RADIO_TO_AIRALARM):null if(frequency) set_frequency(frequency) /obj/machinery/atmospherics/unary/vent_pump/receive_signal(datum/signal/signal) if(stat & (NOPOWER|BROKEN)) return //log_admin("DEBUG \[[world.timeofday]\]: /obj/machinery/atmospherics/unary/vent_pump/receive_signal([signal.debug_print()])") if(!signal.data["tag"] || (signal.data["tag"] != id_tag) || (signal.data["sigtype"]!="command") || (signal.data["type"] && signal.data["type"] != "vent")) return 0 var/handled=0 if("purge" in signal.data) pressure_checks &= ~1 pump_direction = 0 handled=1 if("stabilize" in signal.data) pressure_checks |= 1 pump_direction = 1 handled = 1 if("power" in signal.data) on = text2num(signal.data["power"]) handled = 1 if("power_toggle" in signal.data) on = !on handled = 1 if("checks" in signal.data) pressure_checks = text2num(signal.data["checks"]) handled = 1 if("checks_toggle" in signal.data) pressure_checks = (pressure_checks?0:3) handled = 1 if("direction" in signal.data) pump_direction = text2num(signal.data["direction"]) handled = 1 if("set_internal_pressure" in signal.data) internal_pressure_bound = Clamp(text2num(signal.data["set_internal_pressure"]), 0, ONE_ATMOSPHERE * 50) handled =1 if("set_external_pressure" in signal.data) external_pressure_bound = Clamp(text2num(signal.data["set_external_pressure"]), 0, ONE_ATMOSPHERE * 50) handled = 1 if("adjust_internal_pressure" in signal.data) internal_pressure_bound = Clamp(internal_pressure_bound + text2num(signal.data["adjust_internal_pressure"]), 0, ONE_ATMOSPHERE * 50) handled = 1 if("adjust_external_pressure" in signal.data) external_pressure_bound = Clamp(external_pressure_bound + text2num(signal.data["adjust_external_pressure"]), 0, ONE_ATMOSPHERE * 50) handled = 1 if("init" in signal.data) name = signal.data["init"] return if("status" in signal.data) spawn(2) broadcast_status() return //do not update_icon if(!handled) testing("\[[world.timeofday]\]: vent_pump/receive_signal: unknown command \n[signal.debug_print()]") spawn(2) broadcast_status() update_icon() return /obj/machinery/atmospherics/unary/vent_pump/hide(var/i) //to make the little pipe section invisible, the icon changes. update_icon() return /obj/machinery/atmospherics/unary/vent_pump/examine(mob/user) ..() if(welded) to_chat(user, "It seems welded shut.") /obj/machinery/atmospherics/unary/vent_pump/power_change() if(powered(power_channel)) stat &= ~NOPOWER else stat |= NOPOWER update_icon() /obj/machinery/atmospherics/unary/vent_pump/interact(mob/user as mob) update_multitool_menu(user) /obj/machinery/atmospherics/unary/vent_pump/multitool_menu(var/mob/user,var/obj/item/device/multitool/P) return {"