* Fixes scanners properly this time * Just some code cleanup * Fixes HE pipes being fast * Fixes a bug that, for once, was not my fault * Bugs both my fault and otherwise * Why didn't I just do this in the first place? * Turns out I wasn't the one who did the last one * Simplification * This was just completely incorrect * Just style, which should have been included in the last commit * Use new proc * Simplification. This is still fucked up by the way * And fixes a bug with freezers. This behavior is still fucked up though * Woah fuck I nearly missed this. Freezers no longer have the volume of an entire zone. * This should really be based on partial pressure, but that's a problem for another day * There was never a reason to remove the air since thermal energy change is scale-invariant, dummy * I THINK this is as correct as it's going to get without a rewrite * Reading this hurt me * Forgot this one, long ago * Fuck lifecode * Various stuff * Removing the air is still unnecessary * Fixes these not updating the zones, but these should really adjust thermal energy rather than absolute temperature * Fixes these to update and use pressure * This one gets special mention for breaking any existing sleeping agent in the area * Whoops. I really need to standardize this. * For fuck's sake * I was going to make it adjust the environment temperature directly but looking at the code hurt my skull * Not really deserving of its own commit but R-UST is next * Existence is pain * Fixes compile errors and a trillion runtimes The gas_mixture procs should probably never return null, but oh well * You're solving for the wrong n * Don't explode tanks
234 lines
6.7 KiB
Plaintext
234 lines
6.7 KiB
Plaintext
#define MAX_PRESSURE 4500
|
|
|
|
/*
|
|
Every cycle, the pump uses the air in air_in to try and make air_out the perfect pressure.
|
|
|
|
node1, air1, network1 correspond to input
|
|
node2, air2, network2 correspond to output
|
|
|
|
Thus, the two variables affect pump operation are set in New():
|
|
air1.volume
|
|
This is the volume of gas available to the pump that may be transfered to the output
|
|
air2.volume
|
|
Higher quantities of this cause more air to be perfected later
|
|
but overall network volume is also increased as this increases...
|
|
*/
|
|
|
|
/obj/machinery/atmospherics/binary/pump
|
|
icon = 'icons/obj/atmospherics/pump.dmi'
|
|
icon_state = "intact_off"
|
|
|
|
name = "Gas pump"
|
|
desc = "A pump."
|
|
var/target_pressure = ONE_ATMOSPHERE
|
|
|
|
var/frequency = 0
|
|
var/id_tag = null
|
|
var/datum/radio_frequency/radio_connection
|
|
|
|
machine_flags = MULTITOOL_MENU
|
|
|
|
/obj/machinery/atmospherics/binary/pump/highcap
|
|
name = "High capacity gas pump"
|
|
desc = "A high capacity pump"
|
|
|
|
target_pressure = 15000000 // Holy fuck man
|
|
|
|
/obj/machinery/atmospherics/binary/pump/on
|
|
on = 1
|
|
icon_state = "intact_on"
|
|
|
|
/obj/machinery/atmospherics/binary/pump/update_icon()
|
|
if(stat & NOPOWER)
|
|
icon_state = "intact_off"
|
|
else if(node1 && node2)
|
|
icon_state = "intact_[on?("on"):("off")]"
|
|
..()
|
|
|
|
/obj/machinery/atmospherics/binary/pump/process()
|
|
. = ..()
|
|
if((stat & (NOPOWER|BROKEN)) || !on)
|
|
return
|
|
|
|
var/output_starting_pressure = air2.return_pressure()
|
|
|
|
if( (target_pressure - output_starting_pressure) < 0.01)
|
|
//No need to pump gas if target is already reached!
|
|
return
|
|
|
|
//Calculate necessary moles to transfer using PV=nRT
|
|
if((air1.total_moles() > 0) && (air1.temperature>0))
|
|
var/pressure_delta = target_pressure - output_starting_pressure
|
|
var/transfer_moles = pressure_delta * air2.volume / (air1.temperature * R_IDEAL_GAS_EQUATION)
|
|
|
|
//Actually transfer the gas
|
|
var/datum/gas_mixture/removed = air1.remove(transfer_moles)
|
|
air2.merge(removed)
|
|
|
|
if(network1)
|
|
network1.update = 1
|
|
|
|
if(network2)
|
|
network2.update = 1
|
|
|
|
return 1
|
|
|
|
//Radio remote control
|
|
|
|
|
|
/obj/machinery/atmospherics/binary/pump/proc/set_frequency(new_frequency)
|
|
radio_controller.remove_object(src, frequency)
|
|
frequency = new_frequency
|
|
if(frequency)
|
|
radio_connection = radio_controller.add_object(src, frequency, filter = RADIO_ATMOSIA)
|
|
|
|
/obj/machinery/atmospherics/binary/pump/proc/broadcast_status()
|
|
if(!radio_connection)
|
|
return 0
|
|
|
|
var/datum/signal/signal = getFromPool(/datum/signal)
|
|
signal.transmission_method = 1 //radio signal
|
|
signal.source = src
|
|
|
|
signal.data = list(
|
|
"tag" = id_tag,
|
|
"device" = "AGP",
|
|
"power" = on,
|
|
"target_output" = target_pressure,
|
|
"sigtype" = "status"
|
|
)
|
|
|
|
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
|
|
|
|
return 1
|
|
|
|
/obj/machinery/atmospherics/binary/pump/interact(mob/user as mob)
|
|
var/dat = {"<b>Power: </b><a href='?src=\ref[src];power=1'>[on?"On":"Off"]</a><br>
|
|
<b>Desirable output pressure: </b>
|
|
[round(target_pressure,0.1)]kPa | <a href='?src=\ref[src];set_press=1'>Change</a>
|
|
"}
|
|
|
|
user << browse("<HEAD><TITLE>[src.name] control</TITLE></HEAD><TT>[dat]</TT>", "window=atmo_pump")
|
|
onclose(user, "atmo_pump")
|
|
|
|
/obj/machinery/atmospherics/binary/pump/initialize()
|
|
..()
|
|
if(frequency)
|
|
set_frequency(frequency)
|
|
|
|
|
|
|
|
/obj/machinery/atmospherics/binary/pump/receive_signal(datum/signal/signal)
|
|
if(!CHECK_ATMOS_COMMAND_SIGNAL(SIGNAL_TYPE_ATMOS_GAS_PUMP))
|
|
return 0
|
|
|
|
var/old_on = on
|
|
|
|
switch(signal.data["command"])
|
|
if("power")
|
|
on = text2num(signal.data["value"])
|
|
if("set_target_pressure")
|
|
target_pressure = Clamp(text2num(signal.data["value"]), 0, MAX_PRESSURE)
|
|
investigation_log(I_ATMOS, "was set to [target_pressure] kPa by a remote signal.")
|
|
if("status" in signal.data)
|
|
spawn(2)
|
|
broadcast_status()
|
|
return //do not update_icon
|
|
|
|
spawn(2)
|
|
broadcast_status()
|
|
update_icon()
|
|
|
|
if(old_on != on)
|
|
investigation_log(I_ATMOS,"was turned [on ? "on" : "off"] by a remote signal.")
|
|
|
|
/obj/machinery/atmospherics/binary/pump/attack_hand(user as mob)
|
|
if(..())
|
|
return
|
|
src.add_fingerprint(usr)
|
|
if(!src.allowed(user))
|
|
to_chat(user, "<span class='warning'>Access denied.</span>")
|
|
return
|
|
usr.set_machine(src)
|
|
interact(user)
|
|
return
|
|
|
|
/obj/machinery/atmospherics/binary/pump/multitool_menu(var/mob/user, var/obj/item/device/multitool/P)
|
|
return {"
|
|
<ul>
|
|
<li><b>Frequency:</b> <a href="?src=\ref[src];set_freq=-1">[format_frequency(frequency)] GHz</a> (<a href="?src=\ref[src];set_freq=[1439]">Reset</a>)</li>
|
|
<li>[format_tag("ID Tag","id_tag","set_id")]</a></li>
|
|
</ul>
|
|
"}
|
|
|
|
/obj/machinery/atmospherics/binary/pump/Topic(href,href_list)
|
|
if(..())
|
|
return
|
|
if(href_list["power"])
|
|
on = !on
|
|
investigation_log(I_ATMOS,"was turned [on ? "on" : "off"] by [key_name(usr)].")
|
|
if(href_list["set_press"])
|
|
var/new_pressure = input(usr,"Enter new output pressure (0-[MAX_PRESSURE]kPa)","Pressure control",src.target_pressure) as num
|
|
src.target_pressure = max(0, min(MAX_PRESSURE, new_pressure))
|
|
investigation_log(I_ATMOS,"was set to [target_pressure] kPa by [key_name(usr)].")
|
|
usr.set_machine(src)
|
|
src.update_icon()
|
|
src.updateUsrDialog()
|
|
|
|
/obj/machinery/atmospherics/binary/pump/multitool_topic(var/mob/user, var/list/href_list, var/obj/O)
|
|
if("set_id" in href_list)
|
|
var/newid = copytext(reject_bad_text(input(usr, "Specify the new ID tag for this machine", src, id_tag) as null|text), 1, MAX_MESSAGE_LEN)
|
|
if(newid)
|
|
id_tag = newid
|
|
initialize()
|
|
return MT_UPDATE
|
|
|
|
if("set_freq" in href_list)
|
|
var/newfreq=frequency
|
|
if(href_list["set_freq"]!="-1")
|
|
newfreq=text2num(href_list["set_freq"])
|
|
else
|
|
newfreq = input(usr, "Specify a new frequency (GHz). Decimals assigned automatically.", src, frequency) as null|num
|
|
if(newfreq)
|
|
if(findtext(num2text(newfreq), "."))
|
|
newfreq *= 10 // shift the decimal one place
|
|
if(newfreq < 10000)
|
|
frequency = newfreq
|
|
initialize()
|
|
return MT_UPDATE
|
|
|
|
return ..()
|
|
|
|
/obj/machinery/atmospherics/binary/pump/power_change()
|
|
..()
|
|
update_icon()
|
|
|
|
/obj/machinery/atmospherics/binary/pump/attackby(var/obj/item/weapon/W as obj, var/mob/user as mob)
|
|
if (!iswrench(W))
|
|
return ..()
|
|
if (!(stat & NOPOWER) && on)
|
|
to_chat(user, "<span class='warning'>You cannot unwrench this [src], turn it off first.</span>")
|
|
return 1
|
|
return ..()
|
|
|
|
/obj/machinery/atmospherics/binary/pump/npc_tamper_act(mob/living/L)
|
|
if(prob(50)) //Turn on/off
|
|
on = !on
|
|
investigation_log(I_ATMOS,"was turned [on ? "on" : "off"] by [key_name(L)]")
|
|
else //Change pressure
|
|
src.target_pressure = rand(0, MAX_PRESSURE)
|
|
investigation_log(I_ATMOS,"was set to [target_pressure] kPa by [key_name(L)]")
|
|
|
|
src.update_icon()
|
|
src.updateUsrDialog()
|
|
|
|
/obj/machinery/atmospherics/binary/pump/canClone(var/obj/O)
|
|
return istype(O, /obj/machinery/atmospherics/binary/pump)
|
|
|
|
/obj/machinery/atmospherics/binary/pump/clone(var/obj/machinery/atmospherics/binary/pump/O)
|
|
id_tag = O.id_tag
|
|
set_frequency(O.frequency)
|
|
return 1
|
|
|
|
#undef MAX_PRESSURE
|