var/datum/subsystem/power/SSpower
var/list/power_machines = list()
var/list/datum/powernet/powernets = list() //Holds all powernet datums in use or pooled
var/list/cable_list = list() //Index for all cables, so that powernets don't have to look through the entire world all the time
/datum/subsystem/power
name = "Power"
init_order = SS_INIT_POWER
display_order = SS_DISPLAY_POWER
priority = SS_PRIORITY_POWER
wait = 2 SECONDS
var/list/currentrun_cables
var/list/currentrun_powerents
var/list/currentrun_power_machines
/datum/subsystem/power/New()
NEW_SS_GLOBAL(SSpower)
/datum/subsystem/power/stat_entry()
..("C:[cable_list.len]|PN:[powernets.len]|PM:[power_machines.len]")
/datum/subsystem/power/Initialize(timeofday)
makepowernets()
..()
/datum/subsystem/power/fire(resumed = FALSE)
if (!resumed)
currentrun_cables = global.cable_list.Copy()
currentrun_powerents = global.powernets.Copy()
currentrun_power_machines = global.power_machines.Copy()
// First we reset the powernets.
// This is done first because we want the power machinery to have acted last on the powernet between intervals.
while (currentrun_cables.len)
var/obj/structure/cable/PC = currentrun_cables[currentrun_cables]
currentrun_cables.len--
if (!PC || PC.gcDestroyed)
continue
// Does a powernet need rebuild? Lets do it!
if (PC.build_status && PC.rebuild_from() && MC_TICK_CHECK)
return
while (currentrun_powerents.len)
var/datum/powernet/powerNetwork = currentrun_powerents[currentrun_powerents.len]
currentrun_powerents.len--
if (!powerNetwork || powerNetwork.gcDestroyed)
continue
powerNetwork.reset()
if (MC_TICK_CHECK)
return
// Next we let the power machines operate, this way until the next tick it will be as if they have all done their work.
while (currentrun_power_machines.len)
var/datum/X = currentrun_power_machines[currentrun_power_machines.len]
currentrun_power_machines.len--
if (!X || X.gcDestroyed)
continue
if (istype(X, /obj/machinery))
var/obj/machinery/M = X
if (M.timestopped)
continue
M.check_rebuild() //Checks to make sure the powernet doesn't need to be rebuilt, rebuilds it if it does
if (M.process() == PROCESS_KILL)
M.inMachineList = FALSE
power_machines.Remove(M)
continue
if (M.use_power)
M.auto_use_power()
else if (istype(X, /datum/power_connection))
var/datum/power_connection/C = X
C.check_rebuild() //Checks to make sure the powernet doesn't need to be rebuilt, rebuilds it if it does
if (C.process() == PROCESS_KILL)
C.inMachineList = FALSE
power_machines.Remove(C)
continue
if (MC_TICK_CHECK)