/datum/automation/set_volume_pump_power
|
|
name = "Volume Pump: Power"
|
|
var/pump = null
|
|
var/state = 0
|
|
|
|
/datum/automation/set_volume_pump_power/Export()
|
|
var/list/json = ..()
|
|
json["pump"] = pump
|
|
json["state"] = state
|
|
return json
|
|
|
|
/datum/automation/set_volume_pump_power/Import(var/list/json)
|
|
..(json)
|
|
pump = json["pump"]
|
|
state = text2num(json["state"])
|
|
|
|
/datum/automation/set_volume_pump_power/process()
|
|
if(pump)
|
|
parent.send_signal(list("tag" = pump, "command" = "power", "value" = state, "type" = SIGNAL_TYPE_ATMOS_VOLUME_PUMP))
|
|
return 0
|
|
|
|
/datum/automation/set_volume_pump_power/GetText()
|
|
return "Set volume pump <a href=\"?src=\ref[src];set_pump=1\">[fmtString(pump)]</a> power to <a href=\"?src=\ref[src];toggle_state=1\">[state ? "on" : "off"]</a>."
|
|
|
|
/datum/automation/set_volume_pump_power/Topic(href, href_list)
|
|
. = ..()
|
|
if(.)
|
|
return
|
|
|
|
if(href_list["toggle_state"])
|
|
state = !state
|
|
parent.updateUsrDialog()
|
|
return 1
|
|
|
|
if(href_list["set_pump"])
|
|
var/list/pump_names = list()
|
|
for(var/obj/machinery/atmospherics/binary/volume_pump/I in atmos_machines)
|
|
if(!isnull(I.id_tag) && I.frequency == parent.frequency)
|
|
pump_names |= I.id_tag
|
|
|
|
pump = input("Select a pump:", "Sensor Data", pump) as null | anything in pump_names
|
|
parent.updateUsrDialog()
|
|
return 1
|
|
|
|
/datum/automation/set_volume_pump_rate
|
|
name = "Volume Pump: Rate"
|
|
var/pump = null
|
|
var/rate = 0
|
|
|
|
/datum/automation/set_volume_pump_rate/Export()
|
|
var/list/json = ..()
|
|
json["pump"] = pump
|
|
json["rate"] = rate
|
|
return json
|
|
|
|
/datum/automation/set_volume_pump_rate/Import(var/list/json)
|
|
..(json)
|
|
pump = json["pump"]
|
|
rate = text2num(json["rate"])
|
|
|
|
/datum/automation/set_volume_pump_rate/process()
|
|
if(pump)
|
|
parent.send_signal(list ("tag" = pump, "command" = "set_transfer_rate", "value" = rate, "type" = SIGNAL_TYPE_ATMOS_VOLUME_PUMP))
|
|
return 0
|
|
|
|
/datum/automation/set_volume_pump_rate/GetText()
|
|
return "Set volume pump <a href=\"?src=\ref[src];set_pump=1\">[fmtString(pump)]</a> transfer rate to <a href=\"?src=\ref[src];set_rate=1\">[rate]</a> L/s."
|
|
|
|
/datum/automation/set_volume_pump_rate/Topic(href,href_list)
|
|
. = ..()
|
|
if(.)
|
|
return
|
|
|
|
if(href_list["set_rate"])
|
|
rate = input("Set transfer rate in L/s.", "Rate", rate) as num
|
|
parent.updateUsrDialog()
|
|
return 1
|
|
|
|
if(href_list["set_pump"])
|
|
var/list/pump_names = list()
|
|
for(var/obj/machinery/atmospherics/binary/volume_pump/I in atmos_machines)
|
|
if(!isnull(I.id_tag) && I.frequency == parent.frequency)
|
|
pump_names |= I.id_tag
|
|
if(pump_names.len == 0)
|
|
to_chat(usr, "<span class='warning'>Unable to find any volume pump on this frequency.</span>")
|
|
else
|
|
pump = input("Select a pump:", "Sensor Data", pump) as null | anything in pump_names
|
|
parent.updateUsrDialog()
|
|
return 1
|