Files
vgstation13/code/ATMOSPHERICS/components/binary_devices/passive_gate.dm
clusterfack 6ff70404e8 Fixes any transformation getting people stuck as contents during transformation.
Span class fixes for all of atmospherics files.
Calls new ..() for dice, adds minsides for admins to play with
Fixes bug where people would magically change the size of objects using wrapping paper
2015-03-04 20:23:31 -06:00

165 lines
4.8 KiB
Plaintext

/obj/machinery/atmospherics/binary/passive_gate
//Tries to achieve target pressure at output (like a normal pump) except
// Uses no power but can not transfer gases from a low pressure area to a high pressure area
icon = 'icons/obj/atmospherics/passive_gate.dmi'
icon_state = "intact_off"
name = "Passive gate"
desc = "A one-way air valve that does not require power"
var/on = 0
var/target_pressure = ONE_ATMOSPHERE
var/frequency = 0
var/id_tag = null
var/datum/radio_frequency/radio_connection
/obj/machinery/atmospherics/binary/passive_gate/update_icon()
if(stat & NOPOWER)
icon_state = "intact_off"
else if(node1 && node2)
icon_state = "intact_[on?("on"):("off")]"
else
if(node1)
icon_state = "exposed_1_off"
else if(node2)
icon_state = "exposed_2_off"
else
icon_state = "exposed_3_off"
return
/obj/machinery/atmospherics/binary/passive_gate/process()
..()
if(!on)
return 0
var/output_starting_pressure = air2.return_pressure()
var/input_starting_pressure = air1.return_pressure()
if(output_starting_pressure >= min(target_pressure,input_starting_pressure-10))
//No need to pump gas if target is already reached or input pressure is too low
//Need at least 10 KPa difference to overcome friction in the mechanism
return 1
//Calculate necessary moles to transfer using PV = nRT
if((air1.total_moles() > 0) && (air1.temperature>0))
var/pressure_delta = min(target_pressure - output_starting_pressure, (input_starting_pressure - output_starting_pressure)/2)
//Can not have a pressure delta that would cause output_pressure > input_pressure
var/transfer_moles = pressure_delta*air2.volume/(air1.temperature * R_IDEAL_GAS_EQUATION)
//Actually transfer the gas
var/datum/gas_mixture/removed = air1.remove(transfer_moles)
air2.merge(removed)
if(network1)
network1.update = 1
if(network2)
network2.update = 1
//Radio remote control
/obj/machinery/atmospherics/binary/passive_gate/proc/set_frequency(new_frequency)
radio_controller.remove_object(src, frequency)
frequency = new_frequency
if(frequency)
radio_connection = radio_controller.add_object(src, frequency, filter = RADIO_ATMOSIA)
/obj/machinery/atmospherics/binary/passive_gate/proc/broadcast_status()
if(!radio_connection)
return 0
var/datum/signal/signal = new
signal.transmission_method = 1 //radio signal
signal.source = src
signal.data = list(
"tag" = id_tag,
"device" = "AGP",
"power" = on,
"target_output" = target_pressure,
"sigtype" = "status"
)
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
return 1
/obj/machinery/atmospherics/binary/passive_gate/interact(mob/user as mob)
var/dat = {"<b>Power: </b><a href='?src=\ref[src];power=1'>[on?"On":"Off"]</a><br>
<b>Desirable output pressure: </b>
[round(target_pressure,0.1)]kPa | <a href='?src=\ref[src];set_press=1'>Change</a>
"}
user << browse("<HEAD><TITLE>[src.name] control</TITLE></HEAD><TT>[dat]</TT>", "window=atmo_pump")
onclose(user, "atmo_pump")
/obj/machinery/atmospherics/binary/passive_gate/initialize()
..()
if(frequency)
set_frequency(frequency)
/obj/machinery/atmospherics/binary/passive_gate/receive_signal(datum/signal/signal)
if(!signal.data["tag"] || (signal.data["tag"] != id_tag) || (signal.data["sigtype"]!="command"))
return 0
var/old_on=on
if("power" in signal.data)
on = text2num(signal.data["power"])
if("power_toggle" in signal.data)
on = !on
if("set_output_pressure" in signal.data)
target_pressure = Clamp(
text2num(signal.data["set_output_pressure"]),
0,
ONE_ATMOSPHERE*50
)
if("status" in signal.data)
spawn(2)
broadcast_status()
return //do not update_icon
spawn(2)
broadcast_status()
update_icon()
if(old_on!=on)
investigation_log(I_ATMOS,"was powered [on ? "on" : "off"] by a remote signal")
return
/obj/machinery/atmospherics/binary/passive_gate/attack_hand(user as mob)
if(..())
return
src.add_fingerprint(usr)
if(!src.allowed(user))
user << "<span class='warning'>Access denied.</span>"
return
usr.set_machine(src)
interact(user)
return
/obj/machinery/atmospherics/binary/passive_gate/Topic(href,href_list)
if(..()) return
if(href_list["power"])
on = !on
investigation_log(I_ATMOS,"was turned [on ? "on" : "off"] by [key_name(usr)]")
if(href_list["set_press"])
var/new_pressure = input(usr,"Enter new output pressure (0-4500kPa)","Pressure control",src.target_pressure) as num
src.target_pressure = max(0, min(4500, new_pressure))
investigation_log(I_ATMOS,"was set to [target_pressure] kPa by [key_name(usr)]")
usr.set_machine(src)
src.update_icon()
src.updateUsrDialog()
return
/obj/machinery/atmospherics/binary/passive_gate/power_change()
..()
update_icon()