Files
vgstation13/code/modules/power/power.dm
VivianFoxfoot@gmail.com 8314f5bf5d Fixes some mix-up with what hand was lost
Regenerate admin verb now restores limbs/lost blood
Fixes power_loss proc to actually respect the electrical channel something is on.

git-svn-id: http://tgstation13.googlecode.com/svn/trunk@3539 316c924e-a436-60f5-8080-3fe189b3f50e
2012-05-01 20:53:18 +00:00

499 lines
12 KiB
Plaintext

// common helper procs for all power machines
/obj/machinery/power/proc/add_avail(var/amount)
if(powernet)
powernet.newavail += amount
/obj/machinery/power/proc/add_load(var/amount)
if(powernet)
powernet.newload += amount
/obj/machinery/power/proc/surplus()
if(powernet)
return powernet.avail-powernet.load
else
return 0
/obj/machinery/power/proc/avail()
if(powernet)
return powernet.avail
else
return 0
// returns true if the area has power on given channel (or doesn't require power).
// defaults to equipment channel
/obj/machinery/proc/powered(var/chan = EQUIP)
if(!src.loc)
return 0
var/area/A = src.loc.loc // make sure it's in an area
if(!A || !isarea(A) || !A.master)
return 0 // if not, then not powered
return A.master.powered(power_channel) // return power status of the area
// increment the power usage stats for an area
/obj/machinery/proc/use_power(var/amount, var/chan=EQUIP) // defaults to Equipment channel
var/area/A = src.loc.loc // make sure it's in an area
if(!A || !isarea(A) || !A.master)
return
A.master.use_power(amount, chan)
/obj/machinery/proc/power_change() // called whenever the power settings of the containing area change
// by default, check equipment channel & set flag
// can override if needed
if(powered())
stat &= ~NOPOWER
else
stat |= NOPOWER
return
// the powernet datum
// each contiguous network of cables & nodes
// rebuild all power networks from scratch
/proc/makepowernets()
var/netcount = 0
powernets = list()
for(var/obj/structure/cable/PC in world)
PC.netnum = 0
for(var/obj/machinery/power/M in machines)
if(M.netnum >=0)
M.netnum = 0
for(var/obj/structure/cable/PC in world)
if(!PC.netnum)
PC.netnum = ++netcount
if(Debug) world.log << "Starting mpn at [PC.x],[PC.y] ([PC.d1]/[PC.d2]) #[netcount]"
powernet_nextlink(PC, PC.netnum)
if(Debug) world.log << "[netcount] powernets found"
for(var/L = 1 to netcount)
var/datum/powernet/PN = new()
//PN.tag = "powernet #[L]"
powernets += PN
PN.number = L
for(var/obj/structure/cable/C in world)
var/datum/powernet/PN = powernets[C.netnum]
PN.cables += C
for(var/obj/machinery/power/M in machines)
if(M.netnum<=0) // APCs have netnum=-1 so they don't count as network nodes directly
continue
M.powernet = powernets[M.netnum]
M.powernet.nodes += M
// returns a list of all power-related objects (nodes, cable, junctions) in turf,
// excluding source, that match the direction d
// if unmarked==1, only return those with netnum==0
/proc/power_list(var/turf/T, var/source, var/d, var/unmarked=0)
var/list/result = list()
var/fdir = (!d)? 0 : turn(d, 180) // the opposite direction to d (or 0 if d==0)
for(var/obj/machinery/power/P in T)
if(P.netnum < 0) // exclude APCs
continue
if(P.directwired) // true if this machine covers the whole turf (so can be joined to a cable on neighbour turf)
if(!unmarked || !P.netnum)
result += P
else if(d == 0) // otherwise, need a 0-X cable on same turf to connect
if(!unmarked || !P.netnum)
result += P
for(var/obj/structure/cable/C in T)
if(C.d1 == fdir || C.d2 == fdir)
if(!unmarked || !C.netnum)
result += C
result -= source
return result
/obj/structure/cable/proc/get_connections()
var/list/res = list() // this will be a list of all connected power objects
var/turf/T
if(!d1)
T = src.loc // if d1=0, same turf as src
else
T = get_step(src, d1)
res += power_list(T, src , d1, 1)
T = get_step(src, d2)
res += power_list(T, src, d2, 1)
return res
/obj/machinery/power/proc/get_connections()
if(!directwired)
return get_indirect_connections()
var/list/res = list()
var/cdir
for(var/turf/T in orange(1, src))
cdir = get_dir(T, src)
for(var/obj/structure/cable/C in T)
if(C.netnum)
continue
if(C.d1 == cdir || C.d2 == cdir)
res += C
return res
/obj/machinery/power/proc/get_indirect_connections()
var/list/res = list()
for(var/obj/structure/cable/C in src.loc)
if(C.netnum)
continue
if(C.d1 == 0)
res += C
return res
/proc/powernet_nextlink(var/obj/O, var/num)
var/list/P
//world.log << "start: [O] at [O.x].[O.y]"
while(1)
if( istype(O, /obj/structure/cable) )
var/obj/structure/cable/C = O
C.netnum = num
P = C.get_connections()
else if( istype(O, /obj/machinery/power) )
var/obj/machinery/power/M = O
M.netnum = num
P = M.get_connections()
if(P.len == 0)
//world.log << "end1"
return
O = P[1]
for(var/L = 2 to P.len)
powernet_nextlink(P[L], num)
//world.log << "next: [O] at [O.x].[O.y]"
// cut a powernet at this cable object
/datum/powernet/proc/cut_cable(var/obj/structure/cable/C)
var/turf/T1 = C.loc
if(C.d1)
T1 = get_step(C, C.d1)
var/turf/T2 = get_step(C, C.d2)
var/list/P1 = power_list(T1, C, C.d1) // what joins on to cut cable in dir1
var/list/P2 = power_list(T2, C, C.d2) // what joins on to cut cable in dir2
if(Debug)
for(var/obj/O in P1)
world.log << "P1: [O] at [O.x] [O.y] : [istype(O, /obj/structure/cable) ? "[O:d1]/[O:d2]" : null] "
for(var/obj/O in P2)
world.log << "P2: [O] at [O.x] [O.y] : [istype(O, /obj/structure/cable) ? "[O:d1]/[O:d2]" : null] "
if(P1.len == 0 || P2.len ==0) // if nothing in either list, then the cable was an endpoint
// no need to rebuild the powernet, just remove cut cable from the list
cables -= C
if(Debug) world.log << "Was end of cable"
return
// zero the netnum of all cables & nodes in this powernet
for(var/obj/structure/cable/OC in cables)
OC.netnum = 0
for(var/obj/machinery/power/OM in nodes)
OM.netnum = 0
// remove the cut cable from the network
C.netnum = -1
C.loc = null
cables -= C
powernet_nextlink(P1[1], number) // propagate network from 1st side of cable, using current netnum
// now test to see if propagation reached to the other side
// if so, then there's a loop in the network
var/notlooped = 0
for(var/obj/O in P2)
if( istype(O, /obj/machinery/power) )
var/obj/machinery/power/OM = O
if(OM.netnum != number)
notlooped = 1
break
else if( istype(O, /obj/structure/cable) )
var/obj/structure/cable/OC = O
if(OC.netnum != number)
notlooped = 1
break
if(notlooped)
// not looped, so make a new powernet
var/datum/powernet/PN = new()
//PN.tag = "powernet #[L]"
powernets += PN
PN.number = powernets.len
if(Debug) world.log << "Was not looped: spliting PN#[number] ([cables.len];[nodes.len])"
for(var/obj/structure/cable/OC in cables)
if(!OC.netnum) // non-connected cables will have netnum==0, since they weren't reached by propagation
OC.netnum = PN.number
cables -= OC
PN.cables += OC // remove from old network & add to new one
for(var/obj/machinery/power/OM in nodes)
if(!OM.netnum)
OM.netnum = PN.number
OM.powernet = PN
nodes -= OM
PN.nodes += OM // same for power machines
if(Debug)
world.log << "Old PN#[number] : ([cables.len];[nodes.len])"
world.log << "New PN#[PN.number] : ([PN.cables.len];[PN.nodes.len])"
else
if(Debug)
world.log << "Was looped."
//there is a loop, so nothing to be done
return
return
/datum/powernet/proc/reset()
load = newload
newload = 0
avail = newavail
newavail = 0
viewload = 0.8*viewload + 0.2*load
viewload = round(viewload)
var/numapc = 0
if(nodes) // Added to fix a bad list bug -- TLE
for(var/obj/machinery/power/terminal/term in nodes)
if( istype( term.master, /obj/machinery/power/apc ) )
numapc++
if(numapc)
perapc = avail/numapc
netexcess = avail - load
if( netexcess > 100) // if there was excess power last cycle
for(var/obj/machinery/power/smes/S in nodes) // find the SMESes in the network
S.restore() // and restore some of the power that was used
/datum/powernet/proc/get_electrocute_damage()
switch(avail)/*
if (1300000 to INFINITY)
return min(rand(70,150),rand(70,150))
if (750000 to 1300000)
return min(rand(50,115),rand(50,115))
if (100000 to 750000-1)
return min(rand(35,101),rand(35,101))
if (75000 to 100000-1)
return min(rand(30,95),rand(30,95))
if (50000 to 75000-1)
return min(rand(25,80),rand(25,80))
if (25000 to 50000-1)
return min(rand(20,70),rand(20,70))
if (10000 to 25000-1)
return min(rand(20,65),rand(20,65))
if (1000 to 10000-1)
return min(rand(10,20),rand(10,20))*/
if (1000000 to INFINITY)
return min(rand(50,160),rand(50,160))
if (200000 to 1000000-1)
return min(rand(25,80),rand(25,80))
if (100000 to 200000-1)//Ave powernet
return min(rand(20,60),rand(20,60))
if (50000 to 100000-1)
return min(rand(15,40),rand(15,40))
if (1000 to 50000-1)
return min(rand(10,20),rand(10,20))
else
return 0
/datum/powernet/proc/merge_powernets(var/datum/powernet/P)
// The powernet that calls this proc will consume the other powernet - Rockdtben
if(src == P)
return
if(nodes.len >= P.nodes.len)
nodes += P.nodes
else
P.nodes += nodes
nodes = P.nodes
for(var/obj/machinery/power/M in nodes)
M.netnum = number
M.powernet = powernets[M.netnum] // Thanks to Derp__
if(cables.len >= P.cables.len)
cables += P.cables
else
P.cables += cables
cables = P.cables
for(var/obj/structure/cable/C in cables)
C.netnum = number
del P
/obj/machinery/power/proc/connect_to_network()
var/turf/T = src.loc
var/obj/structure/cable/C = T.get_cable_node()
if (!C || !C.netnum)
return
makepowernets() //TODO: find fast way
/obj/machinery/power/proc/disconnect_from_network()
//TODO: dunno how to do that
return
/turf/proc/get_cable_node()
if(!istype(src, /turf/simulated/floor))
return null
for(var/obj/structure/cable/C in src)
if(C.d1 == 0)
return C
return null
/area/proc/get_apc()
for(var/area/RA in src.related)
var/obj/machinery/power/apc/FINDME = locate() in RA
if (FINDME)
return FINDME
//Determines how strong could be shock, deals damage to mob, uses power.
//M is a mob who touched wire/whatever
//power_source is a source of electricity, can be powercell, area, apc, cable, powernet or null
//source is an object caused electrocuting (airlock, grille, etc)
//No animations will be performed by this proc.
/proc/electrocute_mob(mob/living/carbon/M as mob, var/power_source, var/obj/source, var/siemens_coeff = 1.0)
if(istype(M.loc,/obj/mecha))
return 0
if(istype(M,/mob/living/carbon/human))
var/mob/living/carbon/human/H = M
if(H.gloves)
var/obj/item/clothing/gloves/G = H.gloves
var/siem_coef = G.siemens_coefficient
if(siem_coef == 0) //to avoid spamming with insulated glvoes on
return 0
var/area/source_area
if (istype(power_source,/area))
source_area = power_source
power_source = source_area.get_apc()
if (istype(power_source,/obj/structure/cable))
var/obj/structure/cable/tmp = power_source
power_source = powernets[tmp.netnum]
var/datum/powernet/PN
var/obj/item/weapon/cell/cell
if (istype(power_source,/datum/powernet))
PN = power_source
else if (istype(power_source,/obj/item/weapon/cell))
cell = power_source
else if (istype(power_source,/obj/machinery/power/apc))
var/obj/machinery/power/apc/apc = power_source
cell = apc.cell
if (apc.terminal)
PN = apc.terminal.powernet
else if (!power_source)
return 0
else
log_admin("ERROR: /proc/electrocute_mob([M], [power_source], [source]): wrong power_source")
return 0
if (!cell && !PN)
return 0
var/PN_damage = 0
var/cell_damage = 0
if (PN)
PN_damage = PN.get_electrocute_damage()
if (cell)
cell_damage = cell.get_electrocute_damage()
var/shock_damage = 0
if (PN_damage>=cell_damage)
power_source = PN
shock_damage = PN_damage
else
power_source = cell
shock_damage = cell_damage
var/drained_hp = M.electrocute_act(shock_damage, source, siemens_coeff) //zzzzzzap!
var/drained_energy = drained_hp*20
if (source_area)
source_area.use_power(drained_energy/CELLRATE)
else if (istype(power_source,/datum/powernet))
var/drained_power = drained_energy/CELLRATE //convert from "joules" to "watts"
PN.newload+=drained_power
else if (istype(power_source, /obj/item/weapon/cell))
cell.use(drained_energy)
return drained_energy