atmos cc, cpl
This commit is contained in:
@@ -92,6 +92,7 @@ GLOBAL_LIST_EMPTY(atmos_air_controllers)
|
||||
icon_screen = "tank"
|
||||
icon_keyboard = "atmos_key"
|
||||
circuit = /obj/item/circuitboard/computer/atmos_control
|
||||
light_color = LIGHT_COLOR_CYAN
|
||||
|
||||
var/frequency = FREQ_ATMOS_STORAGE
|
||||
var/list/sensors = list(
|
||||
@@ -102,6 +103,20 @@ GLOBAL_LIST_EMPTY(atmos_air_controllers)
|
||||
ATMOS_GAS_MONITOR_SENSOR_N2O = "Nitrous Oxide Tank",
|
||||
ATMOS_GAS_MONITOR_SENSOR_AIR = "Mixed Air Tank",
|
||||
ATMOS_GAS_MONITOR_SENSOR_MIX = "Mix Tank",
|
||||
// ATMOS_GAS_MONITOR_SENSOR_BZ = "BZ Tank",
|
||||
// ATMOS_GAS_MONITOR_SENSOR_FREON = "Freon Tank",
|
||||
// ATMOS_GAS_MONITOR_SENSOR_HALON = "Halon Tank",
|
||||
// ATMOS_GAS_MONITOR_SENSOR_HEALIUM = "Healium Tank",
|
||||
// ATMOS_GAS_MONITOR_SENSOR_H2 = "Hydrogen Tank",
|
||||
// ATMOS_GAS_MONITOR_SENSOR_HYPERNOBLIUM = "Hypernoblium Tank",
|
||||
// ATMOS_GAS_MONITOR_SENSOR_MIASMA = "Miasma Tank",
|
||||
// ATMOS_GAS_MONITOR_SENSOR_NO2 = "Nitryl Tank",
|
||||
// ATMOS_GAS_MONITOR_SENSOR_PLUOXIUM = "Pluoxium Tank",
|
||||
// ATMOS_GAS_MONITOR_SENSOR_PROTO_NITRATE = "Proto-Nitrate Tank",
|
||||
// ATMOS_GAS_MONITOR_SENSOR_STIMULUM = "Stimulum Tank",
|
||||
// ATMOS_GAS_MONITOR_SENSOR_TRITIUM = "Tritium Tank",
|
||||
// ATMOS_GAS_MONITOR_SENSOR_H2O = "Water Vapor Tank",
|
||||
// ATMOS_GAS_MONITOR_SENSOR_ZAUKER = "Zauker Tank",
|
||||
ATMOS_GAS_MONITOR_LOOP_DISTRIBUTION = "Distribution Loop",
|
||||
ATMOS_GAS_MONITOR_LOOP_ATMOS_WASTE = "Atmos Waste Loop",
|
||||
ATMOS_GAS_MONITOR_SENSOR_INCINERATOR = "Incinerator Chamber",
|
||||
@@ -110,7 +125,6 @@ GLOBAL_LIST_EMPTY(atmos_air_controllers)
|
||||
var/list/sensor_information = list()
|
||||
var/datum/radio_frequency/radio_connection
|
||||
|
||||
light_color = LIGHT_COLOR_CYAN
|
||||
|
||||
/obj/machinery/computer/atmos_control/Initialize()
|
||||
. = ..()
|
||||
@@ -165,15 +179,10 @@ GLOBAL_LIST_EMPTY(atmos_air_controllers)
|
||||
/obj/machinery/computer/atmos_control/incinerator
|
||||
name = "Incinerator Air Control"
|
||||
sensors = list(ATMOS_GAS_MONITOR_SENSOR_INCINERATOR = "Incinerator Chamber")
|
||||
ui_x = 400
|
||||
ui_y = 300
|
||||
|
||||
//Toxins mix sensor only
|
||||
/obj/machinery/computer/atmos_control/toxinsmix
|
||||
name = "Toxins Mixing Air Control"
|
||||
sensors = list(ATMOS_GAS_MONITOR_SENSOR_TOXINS_LAB = "Toxins Mixing Chamber")
|
||||
ui_x = 400
|
||||
ui_y = 300
|
||||
|
||||
/////////////////////////////////////////////////////////////
|
||||
// LARGE TANK CONTROL
|
||||
@@ -184,13 +193,9 @@ GLOBAL_LIST_EMPTY(atmos_air_controllers)
|
||||
var/output_tag
|
||||
frequency = FREQ_ATMOS_STORAGE
|
||||
circuit = /obj/item/circuitboard/computer/atmos_control/tank
|
||||
|
||||
var/list/input_info
|
||||
var/list/output_info
|
||||
|
||||
ui_x = 500
|
||||
ui_y = 315
|
||||
|
||||
/obj/machinery/computer/atmos_control/tank/oxygen_tank
|
||||
name = "Oxygen Supply Control"
|
||||
input_tag = ATMOS_GAS_MONITOR_INPUT_O2
|
||||
@@ -236,7 +241,7 @@ GLOBAL_LIST_EMPTY(atmos_air_controllers)
|
||||
// This hacky madness is the evidence of the fact that a lot of machines were never meant to be constructable, im so sorry you had to see this
|
||||
/obj/machinery/computer/atmos_control/tank/proc/reconnect(mob/user)
|
||||
var/list/IO = list()
|
||||
var/datum/radio_frequency/freq = SSradio.return_frequency(FREQ_ATMOS_STORAGE)
|
||||
var/datum/radio_frequency/freq = SSradio.return_frequency(frequency)
|
||||
var/list/devices = freq.devices["_default"]
|
||||
for(var/obj/machinery/atmospherics/components/unary/vent_pump/U in devices)
|
||||
var/list/text = splittext(U.id_tag, "_")
|
||||
@@ -252,10 +257,11 @@ GLOBAL_LIST_EMPTY(atmos_air_controllers)
|
||||
src.output_tag = "[S]_out"
|
||||
name = "[uppertext(S)] Supply Control"
|
||||
var/list/new_devices = freq.devices["4"]
|
||||
sensors.Cut()
|
||||
for(var/obj/machinery/air_sensor/U in new_devices)
|
||||
var/list/text = splittext(U.id_tag, "_")
|
||||
if(text[1] == S)
|
||||
sensors = list("[S]_sensor" = "Tank")
|
||||
sensors = list("[S]_sensor" = "[S] Tank")
|
||||
break
|
||||
|
||||
for(var/obj/machinery/atmospherics/components/unary/outlet_injector/U in devices)
|
||||
@@ -268,13 +274,16 @@ GLOBAL_LIST_EMPTY(atmos_air_controllers)
|
||||
data["tank"] = TRUE
|
||||
data["inputting"] = input_info ? input_info["power"] : FALSE
|
||||
data["inputRate"] = input_info ? input_info["volume_rate"] : 0
|
||||
data["maxInputRate"] = input_info ? MAX_TRANSFER_RATE : 0
|
||||
data["outputting"] = output_info ? output_info["power"] : FALSE
|
||||
data["outputPressure"] = output_info ? output_info["internal"] : 0
|
||||
|
||||
data["maxOutputPressure"] = output_info ? MAX_OUTPUT_PRESSURE : 0
|
||||
return data
|
||||
|
||||
/obj/machinery/computer/atmos_control/tank/ui_act(action, params)
|
||||
if(..() || !radio_connection)
|
||||
. = ..()
|
||||
|
||||
if(. || !radio_connection)
|
||||
return
|
||||
var/datum/signal/signal = new(list("sigtype" = "command", "user" = usr))
|
||||
switch(action)
|
||||
|
||||
Reference in New Issue