initial commit - cross reference with 5th port - obviously has compile errors

This commit is contained in:
LetterJay
2016-07-03 02:17:19 -05:00
commit 35a1723e98
4355 changed files with 2221257 additions and 0 deletions
@@ -0,0 +1,182 @@
/*
Every cycle, the pump uses the air in air_in to try and make air_out the perfect pressure.
node1, air1, network1 correspond to input
node2, air2, network2 correspond to output
Thus, the two variables affect pump operation are set in New():
air1.volume
This is the volume of gas available to the pump that may be transfered to the output
air2.volume
Higher quantities of this cause more air to be perfected later
but overall network volume is also increased as this increases...
*/
/obj/machinery/atmospherics/components/binary/pump
icon_state = "pump_map"
name = "gas pump"
desc = "A pump that moves gas by pressure."
can_unwrench = 1
var/on = 0
var/target_pressure = ONE_ATMOSPHERE
var/frequency = 0
var/id = null
var/datum/radio_frequency/radio_connection
/obj/machinery/atmospherics/components/binary/pump/on
on = 1
/obj/machinery/atmospherics/components/binary/pump/Destroy()
if(SSradio)
SSradio.remove_object(src,frequency)
if(radio_connection)
radio_connection = null
return ..()
/obj/machinery/atmospherics/components/binary/pump/update_icon_nopipes()
if(stat & NOPOWER)
icon_state = "pump_off"
return
icon_state = "pump_[on?"on":"off"]"
/obj/machinery/atmospherics/components/binary/pump/process_atmos()
// ..()
if(stat & (NOPOWER|BROKEN))
return 0
if(!on)
return 0
var/datum/gas_mixture/air1 = AIR1
var/datum/gas_mixture/air2 = AIR2
var/output_starting_pressure = air2.return_pressure()
if((target_pressure - output_starting_pressure) < 0.01)
//No need to pump gas if target is already reached!
return 1
//Calculate necessary moles to transfer using PV=nRT
if((air1.total_moles() > 0) && (air1.temperature>0))
var/pressure_delta = target_pressure - output_starting_pressure
var/transfer_moles = pressure_delta*air2.volume/(air1.temperature * R_IDEAL_GAS_EQUATION)
//Actually transfer the gas
var/datum/gas_mixture/removed = air1.remove(transfer_moles)
air2.merge(removed)
update_parents()
return 1
//Radio remote control
/obj/machinery/atmospherics/components/binary/pump/proc/set_frequency(new_frequency)
SSradio.remove_object(src, frequency)
frequency = new_frequency
if(frequency)
radio_connection = SSradio.add_object(src, frequency, filter = RADIO_ATMOSIA)
/obj/machinery/atmospherics/components/binary/pump/proc/broadcast_status()
if(!radio_connection)
return 0
var/datum/signal/signal = new
signal.transmission_method = 1 //radio signal
signal.source = src
signal.data = list(
"tag" = id,
"device" = "AGP",
"power" = on,
"target_output" = target_pressure,
"sigtype" = "status"
)
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
return 1
/obj/machinery/atmospherics/components/binary/pump/ui_interact(mob/user, ui_key = "main", datum/tgui/ui = null, force_open = 0, \
datum/tgui/master_ui = null, datum/ui_state/state = default_state)
ui = SStgui.try_update_ui(user, src, ui_key, ui, force_open)
if(!ui)
ui = new(user, src, ui_key, "atmos_pump", name, 335, 115, master_ui, state)
ui.open()
/obj/machinery/atmospherics/components/binary/pump/ui_data()
var/data = list()
data["on"] = on
data["pressure"] = round(target_pressure)
data["max_pressure"] = round(MAX_OUTPUT_PRESSURE)
return data
/obj/machinery/atmospherics/components/binary/pump/ui_act(action, params)
if(..())
return
switch(action)
if("power")
on = !on
investigate_log("was turned [on ? "on" : "off"] by [key_name(usr)]", "atmos")
. = TRUE
if("pressure")
var/pressure = params["pressure"]
if(pressure == "max")
pressure = MAX_OUTPUT_PRESSURE
. = TRUE
else if(pressure == "input")
pressure = input("New output pressure (0-[MAX_OUTPUT_PRESSURE] kPa):", name, target_pressure) as num|null
if(!isnull(pressure) && !..())
. = TRUE
else if(text2num(pressure) != null)
pressure = text2num(pressure)
. = TRUE
if(.)
target_pressure = Clamp(pressure, 0, MAX_OUTPUT_PRESSURE)
investigate_log("was set to [target_pressure] kPa by [key_name(usr)]", "atmos")
update_icon()
/obj/machinery/atmospherics/components/binary/pump/atmosinit()
..()
if(frequency)
set_frequency(frequency)
/obj/machinery/atmospherics/components/binary/pump/receive_signal(datum/signal/signal)
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
return 0
var/old_on = on //for logging
if("power" in signal.data)
on = text2num(signal.data["power"])
if("power_toggle" in signal.data)
on = !on
if("set_output_pressure" in signal.data)
target_pressure = Clamp(text2num(signal.data["set_output_pressure"]),0,ONE_ATMOSPHERE*50)
if(on != old_on)
investigate_log("was turned [on ? "on" : "off"] by a remote signal", "atmos")
if("status" in signal.data)
broadcast_status()
return
broadcast_status()
update_icon()
return
/obj/machinery/atmospherics/components/binary/pump/power_change()
..()
update_icon()
/obj/machinery/atmospherics/components/binary/pump/can_unwrench(mob/user)
if(..())
if(!(stat & NOPOWER) && on)
user << "<span class='warning'>You cannot unwrench this [src], turn it off first!</span>"
else
return 1