Backward 512 compatibility removal.
This commit is contained in:
@@ -282,7 +282,7 @@
|
||||
|
||||
var/new_heat_capacity = air.heat_capacity()
|
||||
if(new_heat_capacity > MINIMUM_HEAT_CAPACITY)
|
||||
air.temperature = CLAMP(((air.temperature*old_heat_capacity + reaction_energy)/new_heat_capacity),TCMB,INFINITY)
|
||||
air.temperature = clamp(((air.temperature*old_heat_capacity + reaction_energy)/new_heat_capacity),TCMB,INFINITY)
|
||||
return REACTING
|
||||
|
||||
/datum/gas_reaction/nitrylformation //The formation of nitryl. Endothermic. Requires N2O as a catalyst.
|
||||
|
||||
@@ -159,13 +159,13 @@
|
||||
pump_direction = 1
|
||||
|
||||
if("set_input_pressure" in signal.data)
|
||||
input_pressure_min = CLAMP(text2num(signal.data["set_input_pressure"]),0,ONE_ATMOSPHERE*50)
|
||||
input_pressure_min = clamp(text2num(signal.data["set_input_pressure"]),0,ONE_ATMOSPHERE*50)
|
||||
|
||||
if("set_output_pressure" in signal.data)
|
||||
output_pressure_max = CLAMP(text2num(signal.data["set_output_pressure"]),0,ONE_ATMOSPHERE*50)
|
||||
output_pressure_max = clamp(text2num(signal.data["set_output_pressure"]),0,ONE_ATMOSPHERE*50)
|
||||
|
||||
if("set_external_pressure" in signal.data)
|
||||
external_pressure_bound = CLAMP(text2num(signal.data["set_external_pressure"]),0,ONE_ATMOSPHERE*50)
|
||||
external_pressure_bound = clamp(text2num(signal.data["set_external_pressure"]),0,ONE_ATMOSPHERE*50)
|
||||
|
||||
if("status" in signal.data)
|
||||
spawn(2)
|
||||
|
||||
@@ -122,7 +122,7 @@ Passive gate is similar to the regular pump except:
|
||||
pressure = text2num(pressure)
|
||||
. = TRUE
|
||||
if(.)
|
||||
target_pressure = CLAMP(pressure, 0, MAX_OUTPUT_PRESSURE)
|
||||
target_pressure = clamp(pressure, 0, MAX_OUTPUT_PRESSURE)
|
||||
investigate_log("was set to [target_pressure] kPa by [key_name(usr)]", INVESTIGATE_ATMOS)
|
||||
update_icon()
|
||||
|
||||
@@ -144,7 +144,7 @@ Passive gate is similar to the regular pump except:
|
||||
on = !on
|
||||
|
||||
if("set_output_pressure" in signal.data)
|
||||
target_pressure = CLAMP(text2num(signal.data["set_output_pressure"]),0,ONE_ATMOSPHERE*50)
|
||||
target_pressure = clamp(text2num(signal.data["set_output_pressure"]),0,ONE_ATMOSPHERE*50)
|
||||
|
||||
if(on != old_on)
|
||||
investigate_log("was turned [on ? "on" : "off"] by a remote signal", INVESTIGATE_ATMOS)
|
||||
|
||||
@@ -145,7 +145,7 @@
|
||||
pressure = text2num(pressure)
|
||||
. = TRUE
|
||||
if(.)
|
||||
target_pressure = CLAMP(pressure, 0, MAX_OUTPUT_PRESSURE)
|
||||
target_pressure = clamp(pressure, 0, MAX_OUTPUT_PRESSURE)
|
||||
investigate_log("was set to [target_pressure] kPa by [key_name(usr)]", INVESTIGATE_ATMOS)
|
||||
update_icon()
|
||||
|
||||
@@ -167,7 +167,7 @@
|
||||
on = !on
|
||||
|
||||
if("set_output_pressure" in signal.data)
|
||||
target_pressure = CLAMP(text2num(signal.data["set_output_pressure"]),0,ONE_ATMOSPHERE*50)
|
||||
target_pressure = clamp(text2num(signal.data["set_output_pressure"]),0,ONE_ATMOSPHERE*50)
|
||||
|
||||
if(on != old_on)
|
||||
investigate_log("was turned [on ? "on" : "off"] by a remote signal", INVESTIGATE_ATMOS)
|
||||
|
||||
@@ -91,7 +91,7 @@
|
||||
pressure = text2num(pressure)
|
||||
. = TRUE
|
||||
if(.)
|
||||
open_pressure = CLAMP(pressure, close_pressure, 50*ONE_ATMOSPHERE)
|
||||
open_pressure = clamp(pressure, close_pressure, 50*ONE_ATMOSPHERE)
|
||||
investigate_log("open pressure was set to [open_pressure] kPa by [key_name(usr)]", INVESTIGATE_ATMOS)
|
||||
if("close_pressure")
|
||||
var/pressure = params["close_pressure"]
|
||||
@@ -106,6 +106,6 @@
|
||||
pressure = text2num(pressure)
|
||||
. = TRUE
|
||||
if(.)
|
||||
close_pressure = CLAMP(pressure, 0, open_pressure)
|
||||
close_pressure = clamp(pressure, 0, open_pressure)
|
||||
investigate_log("close pressure was set to [close_pressure] kPa by [key_name(usr)]", INVESTIGATE_ATMOS)
|
||||
update_icon()
|
||||
|
||||
@@ -135,7 +135,7 @@
|
||||
rate = text2num(rate)
|
||||
. = TRUE
|
||||
if(.)
|
||||
transfer_rate = CLAMP(rate, 0, MAX_TRANSFER_RATE)
|
||||
transfer_rate = clamp(rate, 0, MAX_TRANSFER_RATE)
|
||||
investigate_log("was set to [transfer_rate] L/s by [key_name(usr)]", INVESTIGATE_ATMOS)
|
||||
update_icon()
|
||||
|
||||
@@ -153,7 +153,7 @@
|
||||
|
||||
if("set_transfer_rate" in signal.data)
|
||||
var/datum/gas_mixture/air1 = airs[1]
|
||||
transfer_rate = CLAMP(text2num(signal.data["set_transfer_rate"]),0,air1.volume)
|
||||
transfer_rate = clamp(text2num(signal.data["set_transfer_rate"]),0,air1.volume)
|
||||
|
||||
if(on != old_on)
|
||||
investigate_log("was turned [on ? "on" : "off"] by a remote signal", INVESTIGATE_ATMOS)
|
||||
|
||||
@@ -175,7 +175,7 @@
|
||||
rate = text2num(rate)
|
||||
. = TRUE
|
||||
if(.)
|
||||
transfer_rate = CLAMP(rate, 0, MAX_TRANSFER_RATE)
|
||||
transfer_rate = clamp(rate, 0, MAX_TRANSFER_RATE)
|
||||
investigate_log("was set to [transfer_rate] L/s by [key_name(usr)]", INVESTIGATE_ATMOS)
|
||||
if("filter")
|
||||
filter_type = null
|
||||
|
||||
@@ -164,7 +164,7 @@
|
||||
pressure = text2num(pressure)
|
||||
. = TRUE
|
||||
if(.)
|
||||
target_pressure = CLAMP(pressure, 0, MAX_OUTPUT_PRESSURE)
|
||||
target_pressure = clamp(pressure, 0, MAX_OUTPUT_PRESSURE)
|
||||
investigate_log("was set to [target_pressure] kPa by [key_name(usr)]", INVESTIGATE_ATMOS)
|
||||
if("node1")
|
||||
var/value = text2num(params["concentration"])
|
||||
|
||||
@@ -123,7 +123,7 @@
|
||||
if("set_volume_rate" in signal.data)
|
||||
var/number = text2num(signal.data["set_volume_rate"])
|
||||
var/datum/gas_mixture/air_contents = airs[1]
|
||||
volume_rate = CLAMP(number, 0, air_contents.volume)
|
||||
volume_rate = clamp(number, 0, air_contents.volume)
|
||||
|
||||
if("status" in signal.data)
|
||||
spawn(2)
|
||||
@@ -172,7 +172,7 @@
|
||||
rate = text2num(rate)
|
||||
. = TRUE
|
||||
if(.)
|
||||
volume_rate = CLAMP(rate, 0, MAX_TRANSFER_RATE)
|
||||
volume_rate = clamp(rate, 0, MAX_TRANSFER_RATE)
|
||||
investigate_log("was set to [volume_rate] L/s by [key_name(usr)]", INVESTIGATE_ATMOS)
|
||||
update_icon()
|
||||
broadcast_status()
|
||||
|
||||
@@ -92,7 +92,7 @@
|
||||
pressure = text2num(pressure)
|
||||
. = TRUE
|
||||
if(.)
|
||||
open_pressure = CLAMP(pressure, close_pressure, 50*ONE_ATMOSPHERE)
|
||||
open_pressure = clamp(pressure, close_pressure, 50*ONE_ATMOSPHERE)
|
||||
investigate_log("open pressure was set to [open_pressure] kPa by [key_name(usr)]", INVESTIGATE_ATMOS)
|
||||
if("close_pressure")
|
||||
var/pressure = params["close_pressure"]
|
||||
@@ -107,6 +107,6 @@
|
||||
pressure = text2num(pressure)
|
||||
. = TRUE
|
||||
if(.)
|
||||
close_pressure = CLAMP(pressure, 0, open_pressure)
|
||||
close_pressure = clamp(pressure, 0, open_pressure)
|
||||
investigate_log("close pressure was set to [close_pressure] kPa by [key_name(usr)]", INVESTIGATE_ATMOS)
|
||||
update_icon()
|
||||
|
||||
@@ -170,7 +170,7 @@
|
||||
target = text2num(target)
|
||||
. = TRUE
|
||||
if(.)
|
||||
target_temperature = CLAMP(target, min_temperature, max_temperature)
|
||||
target_temperature = clamp(target, min_temperature, max_temperature)
|
||||
investigate_log("was set to [target_temperature] K by [key_name(usr)]", INVESTIGATE_ATMOS)
|
||||
|
||||
update_icon()
|
||||
|
||||
@@ -210,13 +210,13 @@
|
||||
|
||||
if("set_internal_pressure" in signal.data)
|
||||
var/old_pressure = internal_pressure_bound
|
||||
internal_pressure_bound = CLAMP(text2num(signal.data["set_internal_pressure"]),0,ONE_ATMOSPHERE*50)
|
||||
internal_pressure_bound = clamp(text2num(signal.data["set_internal_pressure"]),0,ONE_ATMOSPHERE*50)
|
||||
if(old_pressure != internal_pressure_bound)
|
||||
investigate_log(" internal pressure was set to [internal_pressure_bound] by [key_name(signal_sender)]",INVESTIGATE_ATMOS)
|
||||
|
||||
if("set_external_pressure" in signal.data)
|
||||
var/old_pressure = external_pressure_bound
|
||||
external_pressure_bound = CLAMP(text2num(signal.data["set_external_pressure"]),0,ONE_ATMOSPHERE*50)
|
||||
external_pressure_bound = clamp(text2num(signal.data["set_external_pressure"]),0,ONE_ATMOSPHERE*50)
|
||||
if(old_pressure != external_pressure_bound)
|
||||
investigate_log(" external pressure was set to [external_pressure_bound] by [key_name(signal_sender)]",INVESTIGATE_ATMOS)
|
||||
|
||||
@@ -227,10 +227,10 @@
|
||||
internal_pressure_bound = 0
|
||||
|
||||
if("adjust_internal_pressure" in signal.data)
|
||||
internal_pressure_bound = CLAMP(internal_pressure_bound + text2num(signal.data["adjust_internal_pressure"]),0,ONE_ATMOSPHERE*50)
|
||||
internal_pressure_bound = clamp(internal_pressure_bound + text2num(signal.data["adjust_internal_pressure"]),0,ONE_ATMOSPHERE*50)
|
||||
|
||||
if("adjust_external_pressure" in signal.data)
|
||||
external_pressure_bound = CLAMP(external_pressure_bound + text2num(signal.data["adjust_external_pressure"]),0,ONE_ATMOSPHERE*50)
|
||||
external_pressure_bound = clamp(external_pressure_bound + text2num(signal.data["adjust_external_pressure"]),0,ONE_ATMOSPHERE*50)
|
||||
|
||||
if("init" in signal.data)
|
||||
name = signal.data["init"]
|
||||
|
||||
@@ -128,7 +128,7 @@
|
||||
if(initialize_directions & dir)
|
||||
return ..()
|
||||
if((NORTH|EAST) & dir)
|
||||
user.ventcrawl_layer = CLAMP(user.ventcrawl_layer + 1, PIPING_LAYER_MIN, PIPING_LAYER_MAX)
|
||||
user.ventcrawl_layer = clamp(user.ventcrawl_layer + 1, PIPING_LAYER_MIN, PIPING_LAYER_MAX)
|
||||
if((SOUTH|WEST) & dir)
|
||||
user.ventcrawl_layer = CLAMP(user.ventcrawl_layer - 1, PIPING_LAYER_MIN, PIPING_LAYER_MAX)
|
||||
user.ventcrawl_layer = clamp(user.ventcrawl_layer - 1, PIPING_LAYER_MIN, PIPING_LAYER_MAX)
|
||||
to_chat(user, "You align yourself with the [user.ventcrawl_layer]\th output.")
|
||||
|
||||
@@ -390,7 +390,7 @@
|
||||
pressure = text2num(pressure)
|
||||
. = TRUE
|
||||
if(.)
|
||||
release_pressure = CLAMP(round(pressure), can_min_release_pressure, can_max_release_pressure)
|
||||
release_pressure = clamp(round(pressure), can_min_release_pressure, can_max_release_pressure)
|
||||
investigate_log("was set to [release_pressure] kPa by [key_name(usr)].", INVESTIGATE_ATMOS)
|
||||
if("valve")
|
||||
var/logmsg
|
||||
@@ -434,7 +434,7 @@
|
||||
var/N = text2num(user_input)
|
||||
if(!N)
|
||||
return
|
||||
timer_set = CLAMP(N,minimum_timer_set,maximum_timer_set)
|
||||
timer_set = clamp(N,minimum_timer_set,maximum_timer_set)
|
||||
log_admin("[key_name(usr)] has activated a prototype valve timer")
|
||||
. = TRUE
|
||||
if("toggle_timer")
|
||||
|
||||
@@ -150,7 +150,7 @@
|
||||
pressure = text2num(pressure)
|
||||
. = TRUE
|
||||
if(.)
|
||||
pump.target_pressure = CLAMP(round(pressure), PUMP_MIN_PRESSURE, PUMP_MAX_PRESSURE)
|
||||
pump.target_pressure = clamp(round(pressure), PUMP_MIN_PRESSURE, PUMP_MAX_PRESSURE)
|
||||
investigate_log("was set to [pump.target_pressure] kPa by [key_name(usr)].", INVESTIGATE_ATMOS)
|
||||
if("eject")
|
||||
if(holding)
|
||||
|
||||
Reference in New Issue