Merge pull request #6995 from Citadel-Station-13/upstream-merge-38240

[MIRROR] Replaces airlock_controller/incinerator related varedits with defines/subtypes
This commit is contained in:
LetterJay
2018-06-05 12:11:34 -05:00
committed by GitHub
12 changed files with 543 additions and 585 deletions
+31
View File
@@ -194,6 +194,37 @@
#define ATMOS_GAS_MONITOR_WASTE_ENGINE "engine-waste_out"
#define ATMOS_GAS_MONITOR_WASTE_ATMOS "atmos-waste_out"
//AIRLOCK CONTROLLER TAGS
//RnD toxins burn chamber
#define INCINERATOR_TOXMIX_IGNITER "toxmix_igniter"
#define INCINERATOR_TOXMIX_VENT "toxmix_vent"
#define INCINERATOR_TOXMIX_DP_VENTPUMP "toxmix_airlock_pump"
#define INCINERATOR_TOXMIX_AIRLOCK_SENSOR "toxmix_airlock_sensor"
#define INCINERATOR_TOXMIX_AIRLOCK_CONTROLLER "toxmix_airlock_controller"
#define INCINERATOR_TOXMIX_AIRLOCK_INTERIOR "toxmix_airlock_interior"
#define INCINERATOR_TOXMIX_AIRLOCK_EXTERIOR "toxmix_airlock_exterior"
//Atmospherics/maintenance incinerator
#define INCINERATOR_ATMOS_IGNITER "atmos_incinerator_igniter"
#define INCINERATOR_ATMOS_MAINVENT "atmos_incinerator_mainvent"
#define INCINERATOR_ATMOS_AUXVENT "atmos_incinerator_auxvent"
#define INCINERATOR_ATMOS_DP_VENTPUMP "atmos_incinerator_airlock_pump"
#define INCINERATOR_ATMOS_AIRLOCK_SENSOR "atmos_incinerator_airlock_sensor"
#define INCINERATOR_ATMOS_AIRLOCK_CONTROLLER "atmos_incinerator_airlock_controller"
#define INCINERATOR_ATMOS_AIRLOCK_INTERIOR "atmos_incinerator_airlock_interior"
#define INCINERATOR_ATMOS_AIRLOCK_EXTERIOR "atmos_incinerator_airlock_exterior"
//Syndicate lavaland base incinerator (lavaland_surface_syndicate_base1.dmm)
#define INCINERATOR_SYNDICATELAVA_IGNITER "syndicatelava_igniter"
#define INCINERATOR_SYNDICATELAVA_MAINVENT "syndicatelava_mainvent"
#define INCINERATOR_SYNDICATELAVA_AUXVENT "syndicatelava_auxvent"
#define INCINERATOR_SYNDICATELAVA_DP_VENTPUMP "syndicatelava_airlock_pump"
#define INCINERATOR_SYNDICATELAVA_AIRLOCK_SENSOR "syndicatelava_airlock_sensor"
#define INCINERATOR_SYNDICATELAVA_AIRLOCK_CONTROLLER "syndicatelava_airlock_controller"
#define INCINERATOR_SYNDICATELAVA_AIRLOCK_INTERIOR "syndicatelava_airlock_interior"
#define INCINERATOR_SYNDICATELAVA_AIRLOCK_EXTERIOR "syndicatelava_airlock_exterior"
//MULTIPIPES
//IF YOU EVER CHANGE THESE CHANGE SPRITES TO MATCH.
#define PIPING_LAYER_MIN 1
+164 -154
View File
@@ -1,154 +1,164 @@
#define AIRLOCK_CONTROL_RANGE 5
// This code allows for airlocks to be controlled externally by setting an id_tag and comm frequency (disables ID access)
/obj/machinery/door/airlock
var/id_tag
var/frequency
var/datum/radio_frequency/radio_connection
/obj/machinery/door/airlock/receive_signal(datum/signal/signal)
if(!signal)
return
if(id_tag != signal.data["tag"] || !signal.data["command"])
return
switch(signal.data["command"])
if("open")
open(1)
if("close")
close(1)
if("unlock")
locked = FALSE
update_icon()
if("lock")
locked = TRUE
update_icon()
if("secure_open")
locked = FALSE
update_icon()
sleep(2)
open(1)
locked = TRUE
update_icon()
if("secure_close")
locked = FALSE
close(1)
locked = TRUE
sleep(2)
update_icon()
send_status()
/obj/machinery/door/airlock/proc/send_status()
if(radio_connection)
var/datum/signal/signal = new(list(
"tag" = id_tag,
"timestamp" = world.time,
"door_status" = density ? "closed" : "open",
"lock_status" = locked ? "locked" : "unlocked"
))
radio_connection.post_signal(src, signal, range = AIRLOCK_CONTROL_RANGE, filter = RADIO_AIRLOCK)
/obj/machinery/door/airlock/open(surpress_send)
. = ..()
if(!surpress_send)
send_status()
/obj/machinery/door/airlock/close(surpress_send)
. = ..()
if(!surpress_send)
send_status()
/obj/machinery/door/airlock/proc/set_frequency(new_frequency)
SSradio.remove_object(src, frequency)
if(new_frequency)
frequency = new_frequency
radio_connection = SSradio.add_object(src, frequency, RADIO_AIRLOCK)
/obj/machinery/door/airlock/Destroy()
if(frequency)
SSradio.remove_object(src,frequency)
return ..()
/obj/machinery/airlock_sensor
icon = 'icons/obj/airlock_machines.dmi'
icon_state = "airlock_sensor_off"
name = "airlock sensor"
resistance_flags = INDESTRUCTIBLE | LAVA_PROOF | FIRE_PROOF | UNACIDABLE | ACID_PROOF
anchored = TRUE
power_channel = ENVIRON
var/id_tag
var/master_tag
var/frequency = FREQ_AIRLOCK_CONTROL
var/datum/radio_frequency/radio_connection
var/on = TRUE
var/alert = FALSE
/obj/machinery/airlock_sensor/update_icon()
if(on)
if(alert)
icon_state = "airlock_sensor_alert"
else
icon_state = "airlock_sensor_standby"
else
icon_state = "airlock_sensor_off"
/obj/machinery/airlock_sensor/attack_hand(mob/user)
. = ..()
if(.)
return
var/datum/signal/signal = new(list(
"tag" = master_tag,
"command" = "cycle"
))
radio_connection.post_signal(src, signal, range = AIRLOCK_CONTROL_RANGE, filter = RADIO_AIRLOCK)
flick("airlock_sensor_cycle", src)
/obj/machinery/airlock_sensor/process()
if(on)
var/datum/gas_mixture/air_sample = return_air()
var/pressure = round(air_sample.return_pressure(),0.1)
alert = (pressure < ONE_ATMOSPHERE*0.8)
var/datum/signal/signal = new(list(
"tag" = id_tag,
"timestamp" = world.time,
"pressure" = num2text(pressure)
))
radio_connection.post_signal(src, signal, range = AIRLOCK_CONTROL_RANGE, filter = RADIO_AIRLOCK)
update_icon()
/obj/machinery/airlock_sensor/proc/set_frequency(new_frequency)
SSradio.remove_object(src, frequency)
frequency = new_frequency
radio_connection = SSradio.add_object(src, frequency, RADIO_AIRLOCK)
/obj/machinery/airlock_sensor/Initialize()
. = ..()
set_frequency(frequency)
/obj/machinery/airlock_sensor/Destroy()
SSradio.remove_object(src,frequency)
return ..()
#define AIRLOCK_CONTROL_RANGE 5
// This code allows for airlocks to be controlled externally by setting an id_tag and comm frequency (disables ID access)
/obj/machinery/door/airlock
var/id_tag
var/frequency
var/datum/radio_frequency/radio_connection
/obj/machinery/door/airlock/receive_signal(datum/signal/signal)
if(!signal)
return
if(id_tag != signal.data["tag"] || !signal.data["command"])
return
switch(signal.data["command"])
if("open")
open(1)
if("close")
close(1)
if("unlock")
locked = FALSE
update_icon()
if("lock")
locked = TRUE
update_icon()
if("secure_open")
locked = FALSE
update_icon()
sleep(2)
open(1)
locked = TRUE
update_icon()
if("secure_close")
locked = FALSE
close(1)
locked = TRUE
sleep(2)
update_icon()
send_status()
/obj/machinery/door/airlock/proc/send_status()
if(radio_connection)
var/datum/signal/signal = new(list(
"tag" = id_tag,
"timestamp" = world.time,
"door_status" = density ? "closed" : "open",
"lock_status" = locked ? "locked" : "unlocked"
))
radio_connection.post_signal(src, signal, range = AIRLOCK_CONTROL_RANGE, filter = RADIO_AIRLOCK)
/obj/machinery/door/airlock/open(surpress_send)
. = ..()
if(!surpress_send)
send_status()
/obj/machinery/door/airlock/close(surpress_send)
. = ..()
if(!surpress_send)
send_status()
/obj/machinery/door/airlock/proc/set_frequency(new_frequency)
SSradio.remove_object(src, frequency)
if(new_frequency)
frequency = new_frequency
radio_connection = SSradio.add_object(src, frequency, RADIO_AIRLOCK)
/obj/machinery/door/airlock/Destroy()
if(frequency)
SSradio.remove_object(src,frequency)
return ..()
/obj/machinery/airlock_sensor
icon = 'icons/obj/airlock_machines.dmi'
icon_state = "airlock_sensor_off"
name = "airlock sensor"
resistance_flags = INDESTRUCTIBLE | LAVA_PROOF | FIRE_PROOF | UNACIDABLE | ACID_PROOF
power_channel = ENVIRON
var/id_tag
var/master_tag
var/frequency = FREQ_AIRLOCK_CONTROL
var/datum/radio_frequency/radio_connection
var/on = TRUE
var/alert = FALSE
/obj/machinery/airlock_sensor/incinerator_toxmix
id_tag = INCINERATOR_TOXMIX_AIRLOCK_SENSOR
master_tag = INCINERATOR_TOXMIX_AIRLOCK_CONTROLLER
/obj/machinery/airlock_sensor/incinerator_atmos
id_tag = INCINERATOR_ATMOS_AIRLOCK_SENSOR
master_tag = INCINERATOR_ATMOS_AIRLOCK_CONTROLLER
/obj/machinery/airlock_sensor/incinerator_syndicatelava
id_tag = INCINERATOR_SYNDICATELAVA_AIRLOCK_SENSOR
master_tag = INCINERATOR_SYNDICATELAVA_AIRLOCK_CONTROLLER
/obj/machinery/airlock_sensor/update_icon()
if(on)
if(alert)
icon_state = "airlock_sensor_alert"
else
icon_state = "airlock_sensor_standby"
else
icon_state = "airlock_sensor_off"
/obj/machinery/airlock_sensor/attack_hand(mob/user)
. = ..()
if(.)
return
var/datum/signal/signal = new(list(
"tag" = master_tag,
"command" = "cycle"
))
radio_connection.post_signal(src, signal, range = AIRLOCK_CONTROL_RANGE, filter = RADIO_AIRLOCK)
flick("airlock_sensor_cycle", src)
/obj/machinery/airlock_sensor/process()
if(on)
var/datum/gas_mixture/air_sample = return_air()
var/pressure = round(air_sample.return_pressure(),0.1)
alert = (pressure < ONE_ATMOSPHERE*0.8)
var/datum/signal/signal = new(list(
"tag" = id_tag,
"timestamp" = world.time,
"pressure" = num2text(pressure)
))
radio_connection.post_signal(src, signal, range = AIRLOCK_CONTROL_RANGE, filter = RADIO_AIRLOCK)
update_icon()
/obj/machinery/airlock_sensor/proc/set_frequency(new_frequency)
SSradio.remove_object(src, frequency)
frequency = new_frequency
radio_connection = SSradio.add_object(src, frequency, RADIO_AIRLOCK)
/obj/machinery/airlock_sensor/Initialize()
. = ..()
set_frequency(frequency)
/obj/machinery/airlock_sensor/Destroy()
SSradio.remove_object(src,frequency)
return ..()
+38
View File
@@ -190,6 +190,31 @@
device = new /obj/item/assembly/control(src)
..()
/obj/machinery/button/door/incinerator_vent_toxmix
name = "combustion chamber vent control"
id = INCINERATOR_TOXMIX_VENT
req_access = list(ACCESS_TOX)
/obj/machinery/button/door/incinerator_vent_atmos_main
name = "turbine vent control"
id = INCINERATOR_ATMOS_MAINVENT
req_one_access = list(ACCESS_ATMOSPHERICS, ACCESS_MAINT_TUNNELS)
/obj/machinery/button/door/incinerator_vent_atmos_aux
name = "combustion chamber vent control"
id = INCINERATOR_ATMOS_AUXVENT
req_one_access = list(ACCESS_ATMOSPHERICS, ACCESS_MAINT_TUNNELS)
/obj/machinery/button/door/incinerator_vent_syndicatelava_main
name = "turbine vent control"
id = INCINERATOR_SYNDICATELAVA_MAINVENT
req_access = list(ACCESS_SYNDICATE)
/obj/machinery/button/door/incinerator_vent_syndicatelava_aux
name = "combustion chamber vent control"
id = INCINERATOR_SYNDICATELAVA_AUXVENT
req_access = list(ACCESS_SYNDICATE)
/obj/machinery/button/massdriver
name = "mass driver button"
desc = "A remote control switch for a mass driver."
@@ -204,6 +229,19 @@
skin = "launcher"
device_type = /obj/item/assembly/control/igniter
/obj/machinery/button/ignition/incinerator
name = "combustion chamber ignition switch"
desc = "A remote control switch for the combustion chamber's igniter."
/obj/machinery/button/ignition/incinerator/toxmix
id = INCINERATOR_TOXMIX_IGNITER
/obj/machinery/button/ignition/incinerator/atmos
id = INCINERATOR_ATMOS_IGNITER
/obj/machinery/button/ignition/incinerator/syndicatelava
id = INCINERATOR_SYNDICATELAVA_IGNITER
/obj/machinery/button/flasher
name = "flasher button"
desc = "A remote control switch for a mounted flasher."
@@ -79,6 +79,20 @@
opacity = 0
glass = TRUE
/obj/machinery/door/airlock/glass/incinerator
autoclose = FALSE
frequency = FREQ_AIRLOCK_CONTROL
heat_proof = TRUE
req_access = list(ACCESS_SYNDICATE)
/obj/machinery/door/airlock/glass/incinerator/syndicatelava_interior
name = "Turbine Interior Airlock"
id_tag = INCINERATOR_SYNDICATELAVA_AIRLOCK_INTERIOR
/obj/machinery/door/airlock/glass/incinerator/syndicatelava_exterior
name = "Turbine Exterior Airlock"
id_tag = INCINERATOR_SYNDICATELAVA_AIRLOCK_EXTERIOR
/obj/machinery/door/airlock/command/glass
opacity = 0
glass = TRUE
@@ -107,6 +121,20 @@
opacity = 0
glass = TRUE
/obj/machinery/door/airlock/research/glass/incinerator
autoclose = FALSE
frequency = FREQ_AIRLOCK_CONTROL
heat_proof = TRUE
req_access = list(ACCESS_TOX)
/obj/machinery/door/airlock/research/glass/incinerator/toxmix_interior
name = "Mixing Room Interior Airlock"
id_tag = INCINERATOR_TOXMIX_AIRLOCK_INTERIOR
/obj/machinery/door/airlock/research/glass/incinerator/toxmix_exterior
name = "Mixing Room Exterior Airlock"
id_tag = INCINERATOR_TOXMIX_AIRLOCK_EXTERIOR
/obj/machinery/door/airlock/mining/glass
opacity = 0
glass = TRUE
@@ -287,6 +315,20 @@
opacity = 0
glass = TRUE
/obj/machinery/door/airlock/public/glass/incinerator
autoclose = FALSE
frequency = FREQ_AIRLOCK_CONTROL
heat_proof = TRUE
req_one_access = list(ACCESS_ATMOSPHERICS, ACCESS_MAINT_TUNNELS)
/obj/machinery/door/airlock/public/glass/incinerator/atmos_interior
name = "Turbine Interior Airlock"
id_tag = INCINERATOR_ATMOS_AIRLOCK_INTERIOR
/obj/machinery/door/airlock/public/glass/incinerator/atmos_exterior
name = "Turbine Exterior Airlock"
id_tag = INCINERATOR_ATMOS_AIRLOCK_EXTERIOR
//////////////////////////////////
/*
External Airlocks
+20
View File
@@ -36,6 +36,26 @@
else
INVOKE_ASYNC(src, .proc/close)
/obj/machinery/door/poddoor/incinerator_toxmix
name = "combustion chamber vent"
id = INCINERATOR_TOXMIX_VENT
/obj/machinery/door/poddoor/incinerator_atmos_main
name = "turbine vent"
id = INCINERATOR_ATMOS_MAINVENT
/obj/machinery/door/poddoor/incinerator_atmos_aux
name = "combustion chamber vent"
id = INCINERATOR_ATMOS_AUXVENT
/obj/machinery/door/poddoor/incinerator_syndicatelava_main
name = "turbine vent"
id = INCINERATOR_SYNDICATELAVA_MAINVENT
/obj/machinery/door/poddoor/incinerator_syndicatelava_aux
name = "combustion chamber vent"
id = INCINERATOR_SYNDICATELAVA_AUXVENT
/obj/machinery/door/poddoor/CollidedWith(atom/movable/AM)
if(density)
return 0
@@ -7,11 +7,11 @@
/datum/computer/file/embedded_program/airlock_controller
var/id_tag
var/exterior_door_tag
var/interior_door_tag
var/airpump_tag
var/sensor_tag
var/sanitize_external
var/exterior_door_tag //Burn chamber facing door
var/interior_door_tag //Station facing door
var/airpump_tag //See: dp_vent_pump.dm
var/sensor_tag //See: /obj/machinery/airlock_sensor
var/sanitize_external //Before the interior airlock opens, do we first drain all gases inside the chamber and then repressurize?
state = AIRLOCK_STATE_CLOSED
var/target_state = AIRLOCK_STATE_CLOSED
@@ -211,6 +211,33 @@
var/sensor_tag
var/sanitize_external
/obj/machinery/embedded_controller/radio/airlock_controller/incinerator_toxmix
name = "Incinerator Access Console"
airpump_tag = INCINERATOR_TOXMIX_DP_VENTPUMP
exterior_door_tag = INCINERATOR_TOXMIX_AIRLOCK_EXTERIOR
id_tag = INCINERATOR_TOXMIX_AIRLOCK_CONTROLLER
interior_door_tag = INCINERATOR_TOXMIX_AIRLOCK_INTERIOR
sanitize_external = TRUE
sensor_tag = INCINERATOR_TOXMIX_AIRLOCK_SENSOR
/obj/machinery/embedded_controller/radio/airlock_controller/incinerator_atmos
name = "Incinerator Access Console"
airpump_tag = INCINERATOR_ATMOS_DP_VENTPUMP
exterior_door_tag = INCINERATOR_ATMOS_AIRLOCK_EXTERIOR
id_tag = INCINERATOR_ATMOS_AIRLOCK_CONTROLLER
interior_door_tag = INCINERATOR_ATMOS_AIRLOCK_INTERIOR
sanitize_external = TRUE
sensor_tag = INCINERATOR_ATMOS_AIRLOCK_SENSOR
/obj/machinery/embedded_controller/radio/airlock_controller/incinerator_syndicatelava
name = "Incinerator Access Console"
airpump_tag = INCINERATOR_SYNDICATELAVA_DP_VENTPUMP
exterior_door_tag = INCINERATOR_SYNDICATELAVA_AIRLOCK_EXTERIOR
id_tag = INCINERATOR_SYNDICATELAVA_AIRLOCK_CONTROLLER
interior_door_tag = INCINERATOR_SYNDICATELAVA_AIRLOCK_INTERIOR
sanitize_external = TRUE
sensor_tag = INCINERATOR_SYNDICATELAVA_AIRLOCK_SENSOR
/obj/machinery/embedded_controller/radio/airlock_controller/Initialize(mapload)
. = ..()
if(!mapload)
+12
View File
@@ -14,6 +14,15 @@
armor = list("melee" = 50, "bullet" = 30, "laser" = 70, "energy" = 50, "bomb" = 20, "bio" = 0, "rad" = 0, "fire" = 100, "acid" = 70)
resistance_flags = FIRE_PROOF
/obj/machinery/igniter/incinerator_toxmix
id = INCINERATOR_TOXMIX_IGNITER
/obj/machinery/igniter/incinerator_atmos
id = INCINERATOR_ATMOS_IGNITER
/obj/machinery/igniter/incinerator_syndicatelava
id = INCINERATOR_SYNDICATELAVA_IGNITER
/obj/machinery/igniter/on
on = TRUE
icon_state = "igniter1"
@@ -60,6 +69,9 @@
anchored = TRUE
resistance_flags = FIRE_PROOF
/obj/machinery/sparker/toxmix
id = INCINERATOR_TOXMIX_IGNITER
/obj/machinery/sparker/Initialize()
. = ..()
spark_system = new /datum/effect_system/spark_spread
@@ -62,6 +62,18 @@ Acts like a normal vent, but has an input AND output.
/obj/machinery/atmospherics/components/binary/dp_vent_pump/high_volume
name = "large dual-port air vent"
/obj/machinery/atmospherics/components/binary/dp_vent_pump/high_volume/incinerator_toxmix
id = INCINERATOR_TOXMIX_DP_VENTPUMP
frequency = FREQ_AIRLOCK_CONTROL
/obj/machinery/atmospherics/components/binary/dp_vent_pump/high_volume/incinerator_atmos
id = INCINERATOR_ATMOS_DP_VENTPUMP
frequency = FREQ_AIRLOCK_CONTROL
/obj/machinery/atmospherics/components/binary/dp_vent_pump/high_volume/incinerator_syndicatelava
id = INCINERATOR_SYNDICATELAVA_DP_VENTPUMP
frequency = FREQ_AIRLOCK_CONTROL
/obj/machinery/atmospherics/components/binary/dp_vent_pump/high_volume/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X