April sync (#360)

* Maps and things no code/icons

* helpers defines globalvars

* Onclick world.dm orphaned_procs

* subsystems

Round vote and shuttle autocall done here too

* datums

* Game folder

* Admin - chatter modules

* clothing - mining

* modular computers - zambies

* client

* mob level 1

* mob stage 2 + simple_animal

* silicons n brains

* mob stage 3 + Alien/Monkey

* human mobs

* icons updated

* some sounds

* emitter y u no commit

* update tgstation.dme

* compile fixes

* travis fixes

Also removes Fast digest mode, because reasons.

* tweaks for travis Mentors are broke again

Also fixes Sizeray guns

* oxygen loss fix for vore code.

* removes unused code

* some code updates

* bulk fixes

* further fixes

* outside things

* whoops.

* Maint bar ported

* GLOBs.
This commit is contained in:
Poojawa
2017-04-13 23:37:00 -05:00
committed by GitHub
parent cdc32c98fa
commit 7e9b96a00f
1322 changed files with 174827 additions and 23888 deletions
@@ -126,7 +126,7 @@ Acts like a normal vent, but has an input AND output.
SSradio.remove_object(src, frequency)
frequency = new_frequency
if(frequency)
radio_connection = SSradio.add_object(src, frequency, filter = RADIO_ATMOSIA)
radio_connection = SSradio.add_object(src, frequency, filter = GLOB.RADIO_ATMOSIA)
/obj/machinery/atmospherics/components/binary/dp_vent_pump/proc/broadcast_status()
if(!radio_connection)
@@ -147,7 +147,7 @@ Acts like a normal vent, but has an input AND output.
"external" = external_pressure_bound,
"sigtype" = "status"
)
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
radio_connection.post_signal(src, signal, filter = GLOB.RADIO_ATMOSIA)
return 1
@@ -70,7 +70,7 @@ Passive gate is similar to the regular pump except:
SSradio.remove_object(src, frequency)
frequency = new_frequency
if(frequency)
radio_connection = SSradio.add_object(src, frequency, filter = RADIO_ATMOSIA)
radio_connection = SSradio.add_object(src, frequency, filter = GLOB.RADIO_ATMOSIA)
/obj/machinery/atmospherics/components/binary/passive_gate/proc/broadcast_status()
if(!radio_connection)
@@ -88,12 +88,12 @@ Passive gate is similar to the regular pump except:
"sigtype" = "status"
)
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
radio_connection.post_signal(src, signal, filter = GLOB.RADIO_ATMOSIA)
return 1
/obj/machinery/atmospherics/components/binary/passive_gate/ui_interact(mob/user, ui_key = "main", datum/tgui/ui = null, force_open = 0, \
datum/tgui/master_ui = null, datum/ui_state/state = default_state)
datum/tgui/master_ui = null, datum/ui_state/state = GLOB.default_state)
ui = SStgui.try_update_ui(user, src, ui_key, ui, force_open)
if(!ui)
ui = new(user, src, ui_key, "atmos_pump", name, 335, 115, master_ui, state)
@@ -77,7 +77,7 @@ Thus, the two variables affect pump operation are set in New():
SSradio.remove_object(src, frequency)
frequency = new_frequency
if(frequency)
radio_connection = SSradio.add_object(src, frequency, filter = RADIO_ATMOSIA)
radio_connection = SSradio.add_object(src, frequency, filter = GLOB.RADIO_ATMOSIA)
/obj/machinery/atmospherics/components/binary/pump/proc/broadcast_status()
if(!radio_connection)
@@ -95,12 +95,12 @@ Thus, the two variables affect pump operation are set in New():
"sigtype" = "status"
)
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
radio_connection.post_signal(src, signal, filter = GLOB.RADIO_ATMOSIA)
return 1
/obj/machinery/atmospherics/components/binary/pump/ui_interact(mob/user, ui_key = "main", datum/tgui/ui = null, force_open = 0, \
datum/tgui/master_ui = null, datum/ui_state/state = default_state)
datum/tgui/master_ui = null, datum/ui_state/state = GLOB.default_state)
ui = SStgui.try_update_ui(user, src, ui_key, ui, force_open)
if(!ui)
ui = new(user, src, ui_key, "atmos_pump", name, 335, 115, master_ui, state)
@@ -95,7 +95,7 @@ Thus, the two variables affect pump operation are set in New():
return 1
/obj/machinery/atmospherics/components/binary/volume_pump/ui_interact(mob/user, ui_key = "main", datum/tgui/ui = null, force_open = 0, \
datum/tgui/master_ui = null, datum/ui_state/state = default_state)
datum/tgui/master_ui = null, datum/ui_state/state = GLOB.default_state)
ui = SStgui.try_update_ui(user, src, ui_key, ui, force_open)
if(!ui)
ui = new(user, src, ui_key, "atmos_pump", name, 310, 115, master_ui, state)
@@ -31,7 +31,7 @@ Iconnery
/obj/machinery/atmospherics/components/proc/icon_addbroken(var/connected = 0)
var/unconnected = (~connected) & initialize_directions
for(var/direction in cardinal)
for(var/direction in GLOB.cardinal)
if(unconnected & direction)
underlays += getpipeimage('icons/obj/atmospherics/components/binary_devices.dmi', "pipe_exposed", direction)
@@ -17,7 +17,7 @@
SSradio.remove_object(src, frequency)
frequency = new_frequency
if(frequency)
radio_connection = SSradio.add_object(src, frequency, RADIO_ATMOSIA)
radio_connection = SSradio.add_object(src, frequency, GLOB.RADIO_ATMOSIA)
/obj/machinery/atmospherics/components/trinary/filter/Destroy()
if(SSradio)
@@ -26,7 +26,7 @@
/obj/machinery/atmospherics/components/trinary/filter/update_icon()
cut_overlays()
for(var/direction in cardinal)
for(var/direction in GLOB.cardinal)
if(direction & initialize_directions)
var/obj/machinery/atmospherics/node = findConnecting(direction)
if(node)
@@ -113,7 +113,7 @@
return ..()
/obj/machinery/atmospherics/components/trinary/filter/ui_interact(mob/user, ui_key = "main", datum/tgui/ui = null, force_open = 0, \
datum/tgui/master_ui = null, datum/ui_state/state = default_state)
datum/tgui/master_ui = null, datum/ui_state/state = GLOB.default_state)
ui = SStgui.try_update_ui(user, src, ui_key, ui, force_open)
if(!ui)
ui = new(user, src, ui_key, "atmos_filter", name, 475, 155, master_ui, state)
@@ -154,9 +154,9 @@
filter_type = ""
var/filter_name = "nothing"
var/gas = params["mode"]
if(gas in meta_gas_info)
if(gas in GLOB.meta_gas_info)
filter_type = gas
filter_name = meta_gas_info[gas][META_GAS_NAME]
filter_name = GLOB.meta_gas_info[gas][META_GAS_NAME]
investigate_log("was set to filter [filter_name] by [key_name(usr)]", "atmos")
. = TRUE
update_icon()
@@ -19,7 +19,7 @@
/obj/machinery/atmospherics/components/trinary/mixer/update_icon()
cut_overlays()
for(var/direction in cardinal)
for(var/direction in GLOB.cardinal)
if(direction & initialize_directions)
var/obj/machinery/atmospherics/node = findConnecting(direction)
if(node)
@@ -117,7 +117,7 @@
return TRUE
/obj/machinery/atmospherics/components/trinary/mixer/ui_interact(mob/user, ui_key = "main", datum/tgui/ui = null, force_open = 0, \
datum/tgui/master_ui = null, datum/ui_state/state = default_state)
datum/tgui/master_ui = null, datum/ui_state/state = GLOB.default_state)
ui = SStgui.try_update_ui(user, src, ui_key, ui, force_open)
if(!ui)
ui = new(user, src, ui_key, "atmos_mixer", name, 370, 165, master_ui, state)
@@ -12,7 +12,7 @@
state_open = FALSE
var/autoeject = FALSE
var/volume = 100
var/running_bob_animation = 0
var/running_bob_animation = FALSE
var/efficiency = 1
var/sleep_factor = 750
@@ -106,7 +106,7 @@
icon_state = "pod1"
var/up = 0 //used to see if we are going up or down, 1 is down, 2 is up
spawn(0) // Without this, the icon update will block. The new thread will die once the occupant leaves.
running_bob_animation = 1
running_bob_animation = TRUE
while(occupant)
overlays -= "lid1" //have to remove the overlays first, to force an update- remove cloning pod overlay
overlays -= pickle //remove mob overlay
@@ -134,7 +134,7 @@
sleep(7) //don't want to jiggle violently, just slowly bob
return
running_bob_animation = 0
running_bob_animation = FALSE
else
icon_state = "pod1"
overlays += "lid0" //have to remove the overlays first, to force an update- remove cloning pod overlay
@@ -160,7 +160,7 @@
playsound(T, 'sound/machines/cryo_warning.ogg', volume, 1) // Bug the doctors.
radio.talk_into(src, "Patient fully restored", radio_channel)
if(autoeject) // Eject if configured.
radio.talk_into(src, "Auto ejecting patient now", radio_channel)
radio.talk_into(src, "Auto ejecting patient now", radio_channel,get_spans(), get_default_language())
open_machine()
return
else if(occupant.stat == DEAD) // We don't bother with dead people.
@@ -280,7 +280,7 @@
return ..()
/obj/machinery/atmospherics/components/unary/cryo_cell/ui_interact(mob/user, ui_key = "main", datum/tgui/ui = null, force_open = 0, \
datum/tgui/master_ui = null, datum/ui_state/state = notcontained_state)
datum/tgui/master_ui = null, datum/ui_state/state = GLOB.notcontained_state)
ui = SStgui.try_update_ui(user, src, ui_key, ui, force_open)
if(!ui)
ui = new(user, src, ui_key, "cryo", name, 400, 550, master_ui, state)
@@ -146,7 +146,7 @@
return UI_CLOSE
/obj/machinery/atmospherics/components/unary/thermomachine/ui_interact(mob/user, ui_key = "main", datum/tgui/ui = null, force_open = 0, \
datum/tgui/master_ui = null, datum/ui_state/state = default_state)
datum/tgui/master_ui = null, datum/ui_state/state = GLOB.default_state)
ui = SStgui.try_update_ui(user, src, ui_key, ui, force_open)
if(!ui)
ui = new(user, src, ui_key, "thermomachine", name, 400, 240, master_ui, state)
@@ -7,7 +7,7 @@
/obj/machinery/atmospherics/components/unary/vent_pump
name = "air vent"
desc = "Has a valve and pump attached to it"
desc = "Has a valve and pump attached to it."
icon_state = "vent_map"
use_power = 1
can_unwrench = 1
@@ -178,8 +178,8 @@
/obj/machinery/atmospherics/components/unary/vent_pump/atmosinit()
//some vents work his own spesial way
radio_filter_in = frequency==1439?(RADIO_FROM_AIRALARM):null
radio_filter_out = frequency==1439?(RADIO_TO_AIRALARM):null
radio_filter_in = frequency==1439?(GLOB.RADIO_FROM_AIRALARM):null
radio_filter_out = frequency==1439?(GLOB.RADIO_TO_AIRALARM):null
if(frequency)
set_frequency(frequency)
broadcast_status()
@@ -3,7 +3,7 @@
/obj/machinery/atmospherics/components/unary/vent_scrubber
name = "air scrubber"
desc = "Has a valve and pump attached to it"
desc = "Has a valve and pump attached to it."
icon_state = "scrub_map"
use_power = 1
idle_power_usage = 10
@@ -142,8 +142,8 @@
return 1
/obj/machinery/atmospherics/components/unary/vent_scrubber/atmosinit()
radio_filter_in = frequency==initial(frequency)?(RADIO_FROM_AIRALARM):null
radio_filter_out = frequency==initial(frequency)?(RADIO_TO_AIRALARM):null
radio_filter_in = frequency==initial(frequency)?(GLOB.RADIO_FROM_AIRALARM):null
radio_filter_out = frequency==initial(frequency)?(GLOB.RADIO_TO_AIRALARM):null
if(frequency)
set_frequency(frequency)
broadcast_status()