Some air alarm tweaks, as requested

First, filtering now filters chemicals by default, too.
Second, draught now only pressurizes up to 1.4x pressure instead of 2x--2x was too much, massive overpressure.
Third, all of the alarm types interact with siphoning vents properly. Panic siphon maximizes siphoning vents, draught sets siphoning vents to lower levels etc.
This commit is contained in:
Putnam3145
2021-12-08 12:44:39 -08:00
parent 0bb3301535
commit 8458823993
2 changed files with 37 additions and 6 deletions
@@ -535,7 +535,7 @@
for(var/device_id in A.air_scrub_names)
send_signal(device_id, list(
"power" = 1,
"set_filters" = list(GAS_CO2, GAS_MIASMA),
"set_filters" = list(GAS_CO2, GAS_MIASMA, GAS_GROUP_CHEMICALS),
"scrubbing" = 1,
"widenet" = 0,
))
@@ -562,7 +562,8 @@
GAS_STIMULUM,
GAS_PLUOXIUM,
GAS_METHANE,
GAS_METHYL_BROMIDE
GAS_METHYL_BROMIDE,
GAS_GROUP_CHEMICALS
),
"scrubbing" = 1,
"widenet" = 1,
@@ -582,9 +583,16 @@
))
for(var/device_id in A.air_vent_names)
send_signal(device_id, list(
"is_pressurizing" = 1,
"power" = 1,
"checks" = 1,
"set_external_pressure" = ONE_ATMOSPHERE*2
"set_external_pressure" = ONE_ATMOSPHERE*1.4
))
send_signal(device_id, list(
"is_siphoning" = 1,
"power" = 1,
"checks" = 1,
"set_external_pressure" = ONE_ATMOSPHERE/1.4
))
if(AALARM_MODE_REFILL)
for(var/device_id in A.air_scrub_names)
@@ -596,10 +604,15 @@
))
for(var/device_id in A.air_vent_names)
send_signal(device_id, list(
"is_pressurizing" = 1,
"power" = 1,
"checks" = 1,
"set_external_pressure" = ONE_ATMOSPHERE * 3
))
send_signal(device_id, list(
"is_siphoning" = 1,
"power" = 0,
))
if(AALARM_MODE_PANIC,
AALARM_MODE_REPLACEMENT)
for(var/device_id in A.air_scrub_names)
@@ -610,8 +623,14 @@
))
for(var/device_id in A.air_vent_names)
send_signal(device_id, list(
"is_pressurizing" = 1,
"power" = 0
))
send_signal(device_id, list(
"is_siphoning" = 1,
"power" = 1,
"checks" = 0
))
if(AALARM_MODE_SIPHON)
for(var/device_id in A.air_scrub_names)
send_signal(device_id, list(
@@ -621,9 +640,14 @@
))
for(var/device_id in A.air_vent_names)
send_signal(device_id, list(
"is_pressurizing" = 1,
"power" = 0
))
send_signal(device_id, list(
"is_siphoning" = 1,
"power" = 1,
"checks" = 0
))
if(AALARM_MODE_OFF)
for(var/device_id in A.air_scrub_names)
send_signal(device_id, list(
@@ -641,8 +665,12 @@
for(var/device_id in A.air_vent_names)
send_signal(device_id, list(
"power" = 1,
"checks" = 2,
"set_internal_pressure" = 0
"checks" = 0,
"is_pressurizing" = 1
))
send_signal(device_id, list(
"power" = 0,
"is_siphoning" = 1
))
/obj/machinery/airalarm/update_icon_state()
@@ -178,6 +178,9 @@
var/mob/signal_sender = signal.data["user"]
if((("is_siphoning" in signal.data) && pump_direction == RELEASING) || (("is_pressurizing" in signal.data) && pump_direction == SIPHONING))
return
if("purge" in signal.data)
pressure_checks &= ~EXT_BOUND
pump_direction = SIPHONING