MF Line endings
This commit is contained in:
+123
-123
@@ -1,123 +1,123 @@
|
||||
//modular computer program version is located in code\modules\modular_computers\file_system\programs\powermonitor.dm, /datum/computer_file/program/power_monitor
|
||||
|
||||
/obj/machinery/computer/monitor
|
||||
name = "power monitoring console"
|
||||
desc = "It monitors power levels across the station."
|
||||
icon_screen = "power"
|
||||
icon_keyboard = "power_key"
|
||||
light_color = LIGHT_COLOR_YELLOW
|
||||
use_power = ACTIVE_POWER_USE
|
||||
idle_power_usage = 20
|
||||
active_power_usage = 100
|
||||
circuit = /obj/item/circuitboard/computer/powermonitor
|
||||
|
||||
var/obj/structure/cable/attached_wire
|
||||
var/obj/machinery/power/apc/local_apc
|
||||
|
||||
var/list/history = list()
|
||||
var/record_size = 60
|
||||
var/record_interval = 50
|
||||
var/next_record = 0
|
||||
var/is_secret_monitor = FALSE
|
||||
tgui_id = "power_monitor"
|
||||
ui_style = "ntos"
|
||||
|
||||
/obj/machinery/computer/monitor/secret //Hides the power monitor (such as ones on ruins & CentCom) from PDA's to prevent metagaming.
|
||||
name = "outdated power monitoring console"
|
||||
desc = "It monitors power levels across the local powernet."
|
||||
circuit = /obj/item/circuitboard/computer/powermonitor/secret
|
||||
is_secret_monitor = TRUE
|
||||
|
||||
/obj/machinery/computer/monitor/secret/examine(mob/user)
|
||||
. = ..()
|
||||
. += "<span class='notice'>It's operating system seems quite outdated... It doesn't seem like it'd be compatible with the latest remote NTOS monitoring systems.</span>"
|
||||
|
||||
/obj/machinery/computer/monitor/Initialize()
|
||||
. = ..()
|
||||
search()
|
||||
history["supply"] = list()
|
||||
history["demand"] = list()
|
||||
|
||||
/obj/machinery/computer/monitor/process()
|
||||
if(!get_powernet())
|
||||
use_power = IDLE_POWER_USE
|
||||
search()
|
||||
else
|
||||
use_power = ACTIVE_POWER_USE
|
||||
record()
|
||||
|
||||
/obj/machinery/computer/monitor/proc/search() //keep in sync with /datum/computer_file/program/power_monitor's version
|
||||
var/turf/T = get_turf(src)
|
||||
attached_wire = locate(/obj/structure/cable) in T
|
||||
if(attached_wire)
|
||||
return
|
||||
var/area/A = get_area(src) //if the computer isn't directly connected to a wire, attempt to find the APC powering it to pull it's powernet instead
|
||||
if(!A)
|
||||
return
|
||||
local_apc = A.get_apc()
|
||||
if(!local_apc)
|
||||
return
|
||||
if(!local_apc.terminal) //this really shouldn't happen without badminnery.
|
||||
local_apc = null
|
||||
|
||||
/obj/machinery/computer/monitor/proc/get_powernet() //keep in sync with /datum/computer_file/program/power_monitor's version
|
||||
if(attached_wire || (local_apc && local_apc.terminal))
|
||||
return attached_wire ? attached_wire.powernet : local_apc.terminal.powernet
|
||||
return FALSE
|
||||
|
||||
/obj/machinery/computer/monitor/proc/record() //keep in sync with /datum/computer_file/program/power_monitor's version
|
||||
if(world.time >= next_record)
|
||||
next_record = world.time + record_interval
|
||||
|
||||
var/datum/powernet/connected_powernet = get_powernet()
|
||||
|
||||
var/list/supply = history["supply"]
|
||||
if(connected_powernet)
|
||||
supply += connected_powernet.viewavail
|
||||
if(supply.len > record_size)
|
||||
supply.Cut(1, 2)
|
||||
|
||||
var/list/demand = history["demand"]
|
||||
if(connected_powernet)
|
||||
demand += connected_powernet.viewload
|
||||
if(demand.len > record_size)
|
||||
demand.Cut(1, 2)
|
||||
|
||||
/obj/machinery/computer/monitor/ui_interact(mob/user, ui_key = "main", datum/tgui/ui = null, force_open = FALSE, \
|
||||
datum/tgui/master_ui = null, datum/ui_state/state = GLOB.default_state)
|
||||
ui = SStgui.try_update_ui(user, src, ui_key, ui, force_open)
|
||||
if(!ui)
|
||||
ui = new(user, src, ui_key, tgui_id, name, 550, 700, master_ui, state)
|
||||
ui.open()
|
||||
|
||||
/obj/machinery/computer/monitor/ui_data()
|
||||
var/datum/powernet/connected_powernet = get_powernet()
|
||||
var/list/data = list()
|
||||
data["stored"] = record_size
|
||||
data["interval"] = record_interval / 10
|
||||
data["attached"] = connected_powernet ? TRUE : FALSE
|
||||
data["history"] = history
|
||||
data["areas"] = list()
|
||||
|
||||
if(connected_powernet)
|
||||
data["supply"] = DisplayPower(connected_powernet.viewavail)
|
||||
data["demand"] = DisplayPower(connected_powernet.viewload)
|
||||
for(var/obj/machinery/power/terminal/term in connected_powernet.nodes)
|
||||
var/obj/machinery/power/apc/A = term.master
|
||||
if(istype(A))
|
||||
var/cell_charge
|
||||
if(!A.cell)
|
||||
cell_charge = 0
|
||||
else
|
||||
cell_charge = A.cell.percent()
|
||||
data["areas"] += list(list(
|
||||
"name" = A.area.name,
|
||||
"charge" = cell_charge,
|
||||
"load" = DisplayPower(A.lastused_total),
|
||||
"charging" = A.charging,
|
||||
"eqp" = A.equipment,
|
||||
"lgt" = A.lighting,
|
||||
"env" = A.environ
|
||||
))
|
||||
|
||||
return data
|
||||
//modular computer program version is located in code\modules\modular_computers\file_system\programs\powermonitor.dm, /datum/computer_file/program/power_monitor
|
||||
|
||||
/obj/machinery/computer/monitor
|
||||
name = "power monitoring console"
|
||||
desc = "It monitors power levels across the station."
|
||||
icon_screen = "power"
|
||||
icon_keyboard = "power_key"
|
||||
light_color = LIGHT_COLOR_YELLOW
|
||||
use_power = ACTIVE_POWER_USE
|
||||
idle_power_usage = 20
|
||||
active_power_usage = 100
|
||||
circuit = /obj/item/circuitboard/computer/powermonitor
|
||||
|
||||
var/obj/structure/cable/attached_wire
|
||||
var/obj/machinery/power/apc/local_apc
|
||||
|
||||
var/list/history = list()
|
||||
var/record_size = 60
|
||||
var/record_interval = 50
|
||||
var/next_record = 0
|
||||
var/is_secret_monitor = FALSE
|
||||
tgui_id = "power_monitor"
|
||||
ui_style = "ntos"
|
||||
|
||||
/obj/machinery/computer/monitor/secret //Hides the power monitor (such as ones on ruins & CentCom) from PDA's to prevent metagaming.
|
||||
name = "outdated power monitoring console"
|
||||
desc = "It monitors power levels across the local powernet."
|
||||
circuit = /obj/item/circuitboard/computer/powermonitor/secret
|
||||
is_secret_monitor = TRUE
|
||||
|
||||
/obj/machinery/computer/monitor/secret/examine(mob/user)
|
||||
. = ..()
|
||||
. += "<span class='notice'>It's operating system seems quite outdated... It doesn't seem like it'd be compatible with the latest remote NTOS monitoring systems.</span>"
|
||||
|
||||
/obj/machinery/computer/monitor/Initialize()
|
||||
. = ..()
|
||||
search()
|
||||
history["supply"] = list()
|
||||
history["demand"] = list()
|
||||
|
||||
/obj/machinery/computer/monitor/process()
|
||||
if(!get_powernet())
|
||||
use_power = IDLE_POWER_USE
|
||||
search()
|
||||
else
|
||||
use_power = ACTIVE_POWER_USE
|
||||
record()
|
||||
|
||||
/obj/machinery/computer/monitor/proc/search() //keep in sync with /datum/computer_file/program/power_monitor's version
|
||||
var/turf/T = get_turf(src)
|
||||
attached_wire = locate(/obj/structure/cable) in T
|
||||
if(attached_wire)
|
||||
return
|
||||
var/area/A = get_area(src) //if the computer isn't directly connected to a wire, attempt to find the APC powering it to pull it's powernet instead
|
||||
if(!A)
|
||||
return
|
||||
local_apc = A.get_apc()
|
||||
if(!local_apc)
|
||||
return
|
||||
if(!local_apc.terminal) //this really shouldn't happen without badminnery.
|
||||
local_apc = null
|
||||
|
||||
/obj/machinery/computer/monitor/proc/get_powernet() //keep in sync with /datum/computer_file/program/power_monitor's version
|
||||
if(attached_wire || (local_apc && local_apc.terminal))
|
||||
return attached_wire ? attached_wire.powernet : local_apc.terminal.powernet
|
||||
return FALSE
|
||||
|
||||
/obj/machinery/computer/monitor/proc/record() //keep in sync with /datum/computer_file/program/power_monitor's version
|
||||
if(world.time >= next_record)
|
||||
next_record = world.time + record_interval
|
||||
|
||||
var/datum/powernet/connected_powernet = get_powernet()
|
||||
|
||||
var/list/supply = history["supply"]
|
||||
if(connected_powernet)
|
||||
supply += connected_powernet.viewavail
|
||||
if(supply.len > record_size)
|
||||
supply.Cut(1, 2)
|
||||
|
||||
var/list/demand = history["demand"]
|
||||
if(connected_powernet)
|
||||
demand += connected_powernet.viewload
|
||||
if(demand.len > record_size)
|
||||
demand.Cut(1, 2)
|
||||
|
||||
/obj/machinery/computer/monitor/ui_interact(mob/user, ui_key = "main", datum/tgui/ui = null, force_open = FALSE, \
|
||||
datum/tgui/master_ui = null, datum/ui_state/state = GLOB.default_state)
|
||||
ui = SStgui.try_update_ui(user, src, ui_key, ui, force_open)
|
||||
if(!ui)
|
||||
ui = new(user, src, ui_key, tgui_id, name, 550, 700, master_ui, state)
|
||||
ui.open()
|
||||
|
||||
/obj/machinery/computer/monitor/ui_data()
|
||||
var/datum/powernet/connected_powernet = get_powernet()
|
||||
var/list/data = list()
|
||||
data["stored"] = record_size
|
||||
data["interval"] = record_interval / 10
|
||||
data["attached"] = connected_powernet ? TRUE : FALSE
|
||||
data["history"] = history
|
||||
data["areas"] = list()
|
||||
|
||||
if(connected_powernet)
|
||||
data["supply"] = DisplayPower(connected_powernet.viewavail)
|
||||
data["demand"] = DisplayPower(connected_powernet.viewload)
|
||||
for(var/obj/machinery/power/terminal/term in connected_powernet.nodes)
|
||||
var/obj/machinery/power/apc/A = term.master
|
||||
if(istype(A))
|
||||
var/cell_charge
|
||||
if(!A.cell)
|
||||
cell_charge = 0
|
||||
else
|
||||
cell_charge = A.cell.percent()
|
||||
data["areas"] += list(list(
|
||||
"name" = A.area.name,
|
||||
"charge" = cell_charge,
|
||||
"load" = DisplayPower(A.lastused_total),
|
||||
"charging" = A.charging,
|
||||
"eqp" = A.equipment,
|
||||
"lgt" = A.lighting,
|
||||
"env" = A.environ
|
||||
))
|
||||
|
||||
return data
|
||||
|
||||
Reference in New Issue
Block a user