Adds multilayer pipe subtypes for mapping (#37341)

* adds multilayer pipe subtypes for mapping

* replaces values with defines
This commit is contained in:
81Denton
2018-04-23 10:33:20 -05:00
committed by CitadelStationBot
parent 3044f3ad3a
commit 8fdc520031
18 changed files with 1069 additions and 0 deletions
@@ -31,10 +31,30 @@ Acts like a normal vent, but has an input AND output.
//EXT_BOUND: Do not pass external_pressure_bound
//INPUT_MIN: Do not pass input_pressure_min
//OUTPUT_MAX: Do not pass output_pressure_max
/obj/machinery/atmospherics/components/binary/dp_vent_pump/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/binary/dp_vent_pump/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/binary/dp_vent_pump/on
on = TRUE
icon_state = "dpvent_map_on"
/obj/machinery/atmospherics/components/binary/dp_vent_pump/on/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/binary/dp_vent_pump/on/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/binary/dp_vent_pump/Destroy()
SSradio.remove_object(src, frequency)
@@ -42,10 +62,30 @@ Acts like a normal vent, but has an input AND output.
/obj/machinery/atmospherics/components/binary/dp_vent_pump/high_volume
name = "large dual-port air vent"
/obj/machinery/atmospherics/components/binary/dp_vent_pump/high_volume/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/binary/dp_vent_pump/high_volume/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/binary/dp_vent_pump/high_volume/on
on = TRUE
icon_state = "dpvent_map_on"
/obj/machinery/atmospherics/components/binary/dp_vent_pump/high_volume/on/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/binary/dp_vent_pump/high_volume/on/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/binary/dp_vent_pump/high_volume/New()
..()
@@ -25,6 +25,16 @@ Passive gate is similar to the regular pump except:
construction_type = /obj/item/pipe/directional
pipe_state = "passivegate"
/obj/machinery/atmospherics/components/binary/passive_gate/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/binary/passive_gate/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/binary/passive_gate/Destroy()
SSradio.remove_object(src,frequency)
@@ -28,11 +28,31 @@ Thus, the two variables affect pump operation are set in New():
construction_type = /obj/item/pipe/directional
pipe_state = "pump"
/obj/machinery/atmospherics/components/binary/pump/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/binary/pump/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/binary/pump/on
on = TRUE
icon_state = "pump_on_map"
/obj/machinery/atmospherics/components/binary/pump/on/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/binary/pump/on/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/binary/pump/Destroy()
SSradio.remove_object(src,frequency)
if(radio_connection)
@@ -19,9 +19,29 @@ It's like a regular ol' straight pipe, but you can turn it on and off.
pipe_state = "mvalve"
var/switching = FALSE
/obj/machinery/atmospherics/components/binary/valve/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/binary/valve/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/binary/valve/open
open = TRUE
/obj/machinery/atmospherics/components/binary/valve/open/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/binary/valve/open/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/binary/valve/update_icon_nopipes(animation = 0)
normalize_dir()
@@ -77,6 +97,16 @@ It's like a regular ol' straight pipe, but you can turn it on and off.
icon_state = "dvalve_map"
valve_type = "d"
pipe_state = "dvalve"
/obj/machinery/atmospherics/components/binary/valve/digital/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/binary/valve/digital/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/binary/valve/digital/attack_ai(mob/user)
return attack_hand(user)
@@ -28,6 +28,16 @@ Thus, the two variables affect pump operation are set in New():
construction_type = /obj/item/pipe/directional
pipe_state = "volumepump"
/obj/machinery/atmospherics/components/binary/volume_pump/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/binary/volume_pump/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/binary/volume_pump/Destroy()
SSradio.remove_object(src,frequency)
@@ -37,6 +47,16 @@ Thus, the two variables affect pump operation are set in New():
on = TRUE
icon_state = "volpump_on_map"
/obj/machinery/atmospherics/components/binary/volume_pump/on/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/binary/volume_pump/on/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/binary/volume_pump/update_icon_nopipes()
if(!is_operational())
icon_state = "volpump_off"
@@ -13,9 +13,29 @@
construction_type = /obj/item/pipe/trinary/flippable
pipe_state = "filter"
/obj/machinery/atmospherics/components/trinary/filter/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/trinary/filter/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/trinary/filter/flipped
icon_state = "filter_off_f"
flipped = TRUE
/obj/machinery/atmospherics/components/trinary/filter/flipped/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/trinary/filter/flipped/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
// These two filter types have critical_machine flagged to on and thus causes the area they are in to be exempt from the Grid Check event.
@@ -17,10 +17,30 @@
//node 3 is the outlet, nodes 1 & 2 are intakes
/obj/machinery/atmospherics/components/trinary/mixer/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/trinary/mixer/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/trinary/mixer/flipped
icon_state = "mixer_off_f"
flipped = TRUE
/obj/machinery/atmospherics/components/trinary/mixer/flipped/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/trinary/mixer/flipped/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/trinary/mixer/airmix //For standard airmix to distro
name = "air mixer"
icon_state = "mixer_on"
@@ -13,6 +13,16 @@
var/update_cycle
pipe_state = "heunary"
/obj/machinery/atmospherics/components/unary/heat_exchanger/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/unary/heat_exchanger/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/unary/heat_exchanger/update_icon()
if(nodes[1])
@@ -19,6 +19,16 @@
layer = GAS_SCRUBBER_LAYER
pipe_state = "injector"
/obj/machinery/atmospherics/components/unary/outlet_injector/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/unary/outlet_injector/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/unary/outlet_injector/Destroy()
SSradio.remove_object(src,frequency)
@@ -65,6 +75,16 @@
/obj/machinery/atmospherics/components/unary/outlet_injector/on
on = TRUE
/obj/machinery/atmospherics/components/unary/outlet_injector/on/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/unary/outlet_injector/on/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/unary/outlet_injector/update_icon_nopipes()
cut_overlays()
@@ -10,6 +10,16 @@
layer = GAS_FILTER_LAYER
pipe_flags = PIPING_ONE_PER_TURF
pipe_state = "connector"
/obj/machinery/atmospherics/components/unary/portables_connector/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/unary/portables_connector/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/unary/portables_connector/New()
..()
@@ -20,6 +30,16 @@
/obj/machinery/atmospherics/components/unary/portables_connector/visible
level = 2
/obj/machinery/atmospherics/components/unary/portables_connector/visible/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/unary/portables_connector/visible/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/unary/portables_connector/process_atmos()
if(!connected_device)
return
@@ -32,20 +32,60 @@
var/radio_filter_in
pipe_state = "uvent"
/obj/machinery/atmospherics/components/unary/vent_pump/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/unary/vent_pump/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/unary/vent_pump/on
on = TRUE
icon_state = "vent_map_on"
/obj/machinery/atmospherics/components/unary/vent_pump/on/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/unary/vent_pump/on/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/unary/vent_pump/siphon
pump_direction = SIPHONING
pressure_checks = INT_BOUND
internal_pressure_bound = 4000
external_pressure_bound = 0
/obj/machinery/atmospherics/components/unary/vent_pump/siphon/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/unary/vent_pump/siphon/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/unary/vent_pump/siphon/on
on = TRUE
icon_state = "vent_map_siphon_on"
/obj/machinery/atmospherics/components/unary/vent_pump/siphon/on/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/unary/vent_pump/siphon/on/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/unary/vent_pump/siphon/atmos
frequency = FREQ_ATMOS_STORAGE
@@ -96,20 +136,60 @@
/obj/machinery/atmospherics/components/unary/vent_pump/high_volume
name = "large air vent"
power_channel = EQUIP
/obj/machinery/atmospherics/components/unary/vent_pump/high_volume/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/unary/vent_pump/high_volume/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/unary/vent_pump/high_volume/on
on = TRUE
icon_state = "vent_map_on"
/obj/machinery/atmospherics/components/unary/vent_pump/high_volume/on/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/unary/vent_pump/high_volume/on/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/unary/vent_pump/high_volume/siphon
pump_direction = SIPHONING
pressure_checks = INT_BOUND
internal_pressure_bound = 2000
external_pressure_bound = 0
/obj/machinery/atmospherics/components/unary/vent_pump/high_volume/siphon/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/unary/vent_pump/high_volume/siphon/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/unary/vent_pump/high_volume/siphon/on
on = TRUE
icon_state = "vent_map_siphon_on"
/obj/machinery/atmospherics/components/unary/vent_pump/high_volume/siphon/on/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/unary/vent_pump/high_volume/siphon/on/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/unary/vent_pump/high_volume/siphon/atmos
frequency = FREQ_ATMOS_STORAGE
@@ -29,6 +29,16 @@
var/radio_filter_in
pipe_state = "scrubber"
/obj/machinery/atmospherics/components/unary/vent_scrubber/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/unary/vent_scrubber/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/unary/vent_scrubber/New()
..()
@@ -42,6 +52,16 @@
/obj/machinery/atmospherics/components/unary/vent_scrubber/on
on = TRUE
icon_state = "scrub_map_on"
/obj/machinery/atmospherics/components/unary/vent_scrubber/on/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/unary/vent_scrubber/on/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/unary/vent_scrubber/Destroy()
var/area/A = get_area(src)