diff --git a/code/game/machinery/embedded_controller/airlock_controller.dm b/code/game/machinery/embedded_controller/airlock_controller.dm
index 6f10d11b2e..f34191370d 100644
--- a/code/game/machinery/embedded_controller/airlock_controller.dm
+++ b/code/game/machinery/embedded_controller/airlock_controller.dm
@@ -1,301 +1,3 @@
-<<<<<<< HEAD
-//States for airlock_control
-#define AIRLOCK_STATE_INOPEN -2
-#define AIRLOCK_STATE_PRESSURIZE -1
-#define AIRLOCK_STATE_CLOSED 0
-#define AIRLOCK_STATE_DEPRESSURIZE 1
-#define AIRLOCK_STATE_OUTOPEN 2
-
-/datum/computer/file/embedded_program/airlock_controller
- var/id_tag
- var/exterior_door_tag
- var/interior_door_tag
- var/airpump_tag
- var/sensor_tag
- var/sanitize_external
-
- state = AIRLOCK_STATE_CLOSED
- var/target_state = AIRLOCK_STATE_CLOSED
- var/sensor_pressure = null
-
-/datum/computer/file/embedded_program/airlock_controller/receive_signal(datum/signal/signal, receive_method, receive_param)
- var/receive_tag = signal.data["tag"]
- if(!receive_tag)
- return
-
- if(receive_tag==sensor_tag)
- if(signal.data["pressure"])
- sensor_pressure = text2num(signal.data["pressure"])
-
- else if(receive_tag==exterior_door_tag)
- memory["exterior_status"] = signal.data["door_status"]
-
- else if(receive_tag==interior_door_tag)
- memory["interior_status"] = signal.data["door_status"]
-
- else if(receive_tag==airpump_tag)
- if(signal.data["power"])
- memory["pump_status"] = signal.data["direction"]
- else
- memory["pump_status"] = "off"
-
- else if(receive_tag==id_tag)
- switch(signal.data["command"])
- if("cycle")
- if(state < AIRLOCK_STATE_CLOSED)
- target_state = AIRLOCK_STATE_OUTOPEN
- else
- target_state = AIRLOCK_STATE_INOPEN
-
-/datum/computer/file/embedded_program/airlock_controller/receive_user_command(command)
- switch(command)
- if("cycle_closed")
- target_state = AIRLOCK_STATE_CLOSED
- if("cycle_exterior")
- target_state = AIRLOCK_STATE_OUTOPEN
- if("cycle_interior")
- target_state = AIRLOCK_STATE_INOPEN
- if("abort")
- target_state = AIRLOCK_STATE_CLOSED
-
-/datum/computer/file/embedded_program/airlock_controller/process()
- var/process_again = 1
- while(process_again)
- process_again = 0
- switch(state)
- if(AIRLOCK_STATE_INOPEN) // state -2
- if(target_state > state)
- if(memory["interior_status"] == "closed")
- state = AIRLOCK_STATE_CLOSED
- process_again = 1
- else
- var/datum/signal/signal = new
- signal.data["tag"] = interior_door_tag
- signal.data["command"] = "secure_close"
- post_signal(signal)
- else
- if(memory["pump_status"] != "off")
- var/datum/signal/signal = new
- signal.data = list(
- "tag" = airpump_tag,
- "power" = 0,
- "sigtype"="command"
- )
- post_signal(signal)
-
- if(AIRLOCK_STATE_PRESSURIZE)
- if(target_state < state)
- if(sensor_pressure >= ONE_ATMOSPHERE*0.95)
- if(memory["interior_status"] == "open")
- state = AIRLOCK_STATE_INOPEN
- process_again = 1
- else
- var/datum/signal/signal = new
- signal.data["tag"] = interior_door_tag
- signal.data["command"] = "secure_open"
- post_signal(signal)
- else
- var/datum/signal/signal = new
- signal.data = list(
- "tag" = airpump_tag,
- "sigtype"="command"
- )
- if(memory["pump_status"] == "siphon")
- signal.data["stabalize"] = 1
- else if(memory["pump_status"] != "release")
- signal.data["power"] = 1
- post_signal(signal)
- else if(target_state > state)
- state = AIRLOCK_STATE_CLOSED
- process_again = 1
-
- if(AIRLOCK_STATE_CLOSED)
- if(target_state > state)
- if(memory["interior_status"] == "closed")
- state = AIRLOCK_STATE_DEPRESSURIZE
- process_again = 1
- else
- var/datum/signal/signal = new
- signal.data["tag"] = interior_door_tag
- signal.data["command"] = "secure_close"
- post_signal(signal)
- else if(target_state < state)
- if(memory["exterior_status"] == "closed")
- state = AIRLOCK_STATE_PRESSURIZE
- process_again = 1
- else
- var/datum/signal/signal = new
- signal.data["tag"] = exterior_door_tag
- signal.data["command"] = "secure_close"
- post_signal(signal)
-
- else
- if(memory["pump_status"] != "off")
- var/datum/signal/signal = new
- signal.data = list(
- "tag" = airpump_tag,
- "power" = 0,
- "sigtype"="command"
- )
- post_signal(signal)
-
- if(AIRLOCK_STATE_DEPRESSURIZE)
- var/target_pressure = ONE_ATMOSPHERE*0.05
- if(sanitize_external)
- target_pressure = ONE_ATMOSPHERE*0.01
-
- if(sensor_pressure <= target_pressure)
- if(target_state > state)
- if(memory["exterior_status"] == "open")
- state = AIRLOCK_STATE_OUTOPEN
- else
- var/datum/signal/signal = new
- signal.data["tag"] = exterior_door_tag
- signal.data["command"] = "secure_open"
- post_signal(signal)
- else if(target_state < state)
- state = AIRLOCK_STATE_CLOSED
- process_again = 1
- else if((target_state < state) && !sanitize_external)
- state = AIRLOCK_STATE_CLOSED
- process_again = 1
- else
- var/datum/signal/signal = new
- signal.transmission_method = 1 //radio signal
- signal.data = list(
- "tag" = airpump_tag,
- "sigtype"="command"
- )
- if(memory["pump_status"] == "release")
- signal.data["purge"] = 1
- else if(memory["pump_status"] != "siphon")
- signal.data["power"] = 1
- post_signal(signal)
-
- if(AIRLOCK_STATE_OUTOPEN) //state 2
- if(target_state < state)
- if(memory["exterior_status"] == "closed")
- if(sanitize_external)
- state = AIRLOCK_STATE_DEPRESSURIZE
- process_again = 1
- else
- state = AIRLOCK_STATE_CLOSED
- process_again = 1
- else
- var/datum/signal/signal = new
- signal.data["tag"] = exterior_door_tag
- signal.data["command"] = "secure_close"
- post_signal(signal)
- else
- if(memory["pump_status"] != "off")
- var/datum/signal/signal = new
- signal.data = list(
- "tag" = airpump_tag,
- "power" = 0,
- "sigtype"="command"
- )
- post_signal(signal)
-
- memory["sensor_pressure"] = sensor_pressure
- memory["processing"] = state != target_state
- //sensor_pressure = null //not sure if we can comment this out. Uncomment in case of problems -rastaf0
-
- return 1
-
-
-/obj/machinery/embedded_controller/radio/airlock_controller
- icon = 'icons/obj/airlock_machines.dmi'
- icon_state = "airlock_control_standby"
-
- name = "airlock console"
- density = FALSE
-
- frequency = 1449
- power_channel = ENVIRON
-
- // Setup parameters only
- var/id_tag
- var/exterior_door_tag
- var/interior_door_tag
- var/airpump_tag
- var/sensor_tag
- var/sanitize_external
-
-/obj/machinery/embedded_controller/radio/airlock_controller/Initialize(mapload)
- . = ..()
- if(!mapload)
- return
-
- var/datum/computer/file/embedded_program/airlock_controller/new_prog = new
-
- new_prog.id_tag = id_tag
- new_prog.exterior_door_tag = exterior_door_tag
- new_prog.interior_door_tag = interior_door_tag
- new_prog.airpump_tag = airpump_tag
- new_prog.sensor_tag = sensor_tag
- new_prog.sanitize_external = sanitize_external
-
- new_prog.master = src
- program = new_prog
-
-/obj/machinery/embedded_controller/radio/airlock_controller/update_icon()
- if(on && program)
- if(program.memory["processing"])
- icon_state = "airlock_control_process"
- else
- icon_state = "airlock_control_standby"
- else
- icon_state = "airlock_control_off"
-
-
-/obj/machinery/embedded_controller/radio/airlock_controller/return_text()
- var/state_options = null
-
- var/state = 0
- var/sensor_pressure = "----"
- var/exterior_status = "----"
- var/interior_status = "----"
- var/pump_status = "----"
- var/current_status = "Inactive
"
- if(program)
- state = program.state
- sensor_pressure = program.memory["sensor_pressure"] ? program.memory["sensor_pressure"] : "----"
- exterior_status = program.memory["exterior_status"] ? program.memory["exterior_status"] : "----"
- interior_status = program.memory["interior_status"] ? program.memory["interior_status"] : "----"
- pump_status = program.memory["pump_status"] ? program.memory["pump_status"] : "----"
-
- switch(state)
- if(AIRLOCK_STATE_INOPEN)
- state_options = {"Close Interior Airlock
-Cycle to Exterior Airlock
"}
- current_status = "Interior Airlock Open
Chamber Pressurized"
- if(AIRLOCK_STATE_PRESSURIZE)
- state_options = "Abort Cycling
"
- current_status = "Cycling to Interior Airlock
Chamber Pressurizing"
- if(AIRLOCK_STATE_CLOSED)
- state_options = {"Open Interior Airlock
-Open Exterior Airlock
"}
- if(AIRLOCK_STATE_DEPRESSURIZE)
- state_options = "Abort Cycling
"
- current_status = "Cycling to Exterior Airlock
Chamber Depressurizing"
- if(AIRLOCK_STATE_OUTOPEN)
- state_options = {"Cycle to Interior Airlock
-Close Exterior Airlock
"}
- current_status = "Exterior Airlock Open
Chamber Depressurized"
-
- var/output = {"