From a549f3128ac28ca87701024439d4320fbdd0dfb9 Mon Sep 17 00:00:00 2001 From: LetterJay Date: Tue, 12 Sep 2017 03:02:15 -0500 Subject: [PATCH] Update atmos_control.dm --- code/game/machinery/computer/atmos_control.dm | 433 +++++++++--------- 1 file changed, 206 insertions(+), 227 deletions(-) diff --git a/code/game/machinery/computer/atmos_control.dm b/code/game/machinery/computer/atmos_control.dm index 310a6e3027..8131dbd4a6 100644 --- a/code/game/machinery/computer/atmos_control.dm +++ b/code/game/machinery/computer/atmos_control.dm @@ -1,67 +1,47 @@ -///////////////////////////////////////////////////////////// -// AIR SENSOR (found in gas tanks) -///////////////////////////////////////////////////////////// - -/obj/machinery/air_sensor - name = "gas sensor" - icon = 'icons/obj/stationobjs.dmi' - icon_state = "gsensor1" +///////////////////////////////////////////////////////////// +// AIR SENSOR (found in gas tanks) +///////////////////////////////////////////////////////////// + +/obj/machinery/air_sensor + name = "gas sensor" + icon = 'icons/obj/stationobjs.dmi' + icon_state = "gsensor1" anchored = TRUE - - var/on = TRUE - - var/id_tag - var/frequency = 1441 - var/datum/radio_frequency/radio_connection - -/obj/machinery/air_sensor/update_icon() - icon_state = "gsensor[on]" - -/obj/machinery/air_sensor/process_atmos() - if(on) - var/datum/signal/signal = new - var/datum/gas_mixture/air_sample = return_air() - - signal.transmission_method = 1 //radio signal - signal.data = list( - "sigtype" = "status", - "id_tag" = id_tag, - "timestamp" = world.time, - "pressure" = air_sample.return_pressure(), - "temperature" = air_sample.temperature, - "gases" = list() - ) - var/total_moles = air_sample.total_moles() - if(total_moles) - for(var/gas_id in air_sample.gases) - var/gas_name = air_sample.gases[gas_id][GAS_META][META_GAS_NAME] - signal.data["gases"][gas_name] = air_sample.gases[gas_id][MOLES] / total_moles * 100 - - radio_connection.post_signal(src, signal, filter = GLOB.RADIO_ATMOSIA) - - -/obj/machinery/air_sensor/proc/set_frequency(new_frequency) - SSradio.remove_object(src, frequency) - frequency = new_frequency - radio_connection = SSradio.add_object(src, frequency, GLOB.RADIO_ATMOSIA) - -/obj/machinery/air_sensor/Initialize() - ..() - SSair.atmos_machinery += src - set_frequency(frequency) - -/obj/machinery/air_sensor/Destroy() - SSair.atmos_machinery -= src + + var/on = TRUE + + var/id_tag + var/frequency = 1441 + var/datum/radio_frequency/radio_connection + +/obj/machinery/air_sensor/update_icon() + icon_state = "gsensor[on]" + +/obj/machinery/air_sensor/process_atmos() + if(on) + var/datum/signal/signal = new + var/datum/gas_mixture/air_sample = return_air() + + signal.transmission_method = 1 //radio signal + signal.data = list( + "sigtype" = "status", + "id_tag" = id_tag, + "timestamp" = world.time, + "pressure" = air_sample.return_pressure(), + "temperature" = air_sample.temperature, + "gases" = list() + ) + var/total_moles = air_sample.total_moles() + if(total_moles) + for(var/gas_id in air_sample.gases) + var/gas_name = air_sample.gases[gas_id][GAS_META][META_GAS_NAME] + signal.data["gases"][gas_name] = air_sample.gases[gas_id][MOLES] / total_moles * 100 + + radio_connection.post_signal(src, signal, filter = GLOB.RADIO_ATMOSIA) + + +/obj/machinery/air_sensor/proc/set_frequency(new_frequency) SSradio.remove_object(src, frequency) -<<<<<<< HEAD - return ..() - -///////////////////////////////////////////////////////////// -// GENERAL AIR CONTROL (a.k.a atmos computer) -///////////////////////////////////////////////////////////// - -/obj/machinery/computer/atmos_control -======= frequency = new_frequency radio_connection = SSradio.add_object(src, frequency, GLOB.RADIO_ATMOSIA) @@ -80,172 +60,171 @@ ///////////////////////////////////////////////////////////// /obj/machinery/computer/atmos_control ->>>>>>> f2c5657... Fixes initialize hints for a fair number of mobs and items (#30583) name = "atmospherics monitoring" - desc = "Used to monitor the station's atmospherics sensors." - icon_screen = "tank" - icon_keyboard = "atmos_key" - circuit = /obj/item/circuitboard/computer/atmos_control - - var/frequency = 1441 - var/list/sensors = list( - "n2_sensor" = "Nitrogen Tank", - "o2_sensor" = "Oxygen Tank", - "co2_sensor" = "Carbon Dioxide Tank", - "tox_sensor" = "Plasma Tank", - "n2o_sensor" = "Nitrous Oxide Tank", - "air_sensor" = "Mixed Air Tank", - "mix_sensor" = "Mix Tank", - "distro_meter" = "Distribution Loop", - "waste_meter" = "Waste Loop", - ) - var/list/sensor_information = list() - var/datum/radio_frequency/radio_connection - - light_color = LIGHT_COLOR_CYAN - -/obj/machinery/computer/atmos_control/Initialize() - ..() - set_frequency(frequency) - -/obj/machinery/computer/atmos_control/Destroy() + desc = "Used to monitor the station's atmospherics sensors." + icon_screen = "tank" + icon_keyboard = "atmos_key" + circuit = /obj/item/circuitboard/computer/atmos_control + + var/frequency = 1441 + var/list/sensors = list( + "n2_sensor" = "Nitrogen Tank", + "o2_sensor" = "Oxygen Tank", + "co2_sensor" = "Carbon Dioxide Tank", + "tox_sensor" = "Plasma Tank", + "n2o_sensor" = "Nitrous Oxide Tank", + "air_sensor" = "Mixed Air Tank", + "mix_sensor" = "Mix Tank", + "distro_meter" = "Distribution Loop", + "waste_meter" = "Waste Loop", + ) + var/list/sensor_information = list() + var/datum/radio_frequency/radio_connection + + light_color = LIGHT_COLOR_CYAN + +/obj/machinery/computer/atmos_control/Initialize() + ..() + set_frequency(frequency) + +/obj/machinery/computer/atmos_control/Destroy() SSradio.remove_object(src, frequency) - return ..() - + return ..() + /obj/machinery/computer/atmos_control/ui_interact(mob/user, ui_key = "main", datum/tgui/ui = null, force_open = FALSE, \ - datum/tgui/master_ui = null, datum/ui_state/state = GLOB.default_state) - ui = SStgui.try_update_ui(user, src, ui_key, ui, force_open) - if(!ui) - ui = new(user, src, ui_key, "atmos_control", name, 400, 925, master_ui, state) - ui.open() - -/obj/machinery/computer/atmos_control/ui_data(mob/user) - var/data = list() - - data["sensors"] = list() - for(var/id_tag in sensors) - var/long_name = sensors[id_tag] - var/list/info = sensor_information[id_tag] - if(!info) - continue - data["sensors"] += list(list( - "id_tag" = id_tag, - "long_name" = sanitize(long_name), - "pressure" = info["pressure"], - "temperature" = info["temperature"], - "gases" = info["gases"] - )) - return data - -/obj/machinery/computer/atmos_control/receive_signal(datum/signal/signal) - if(!signal || signal.encryption) - return - - var/id_tag = signal.data["id_tag"] - if(!id_tag || !sensors.Find(id_tag)) - return - - sensor_information[id_tag] = signal.data - -/obj/machinery/computer/atmos_control/proc/set_frequency(new_frequency) - SSradio.remove_object(src, frequency) - frequency = new_frequency - radio_connection = SSradio.add_object(src, frequency, GLOB.RADIO_ATMOSIA) - -///////////////////////////////////////////////////////////// -// LARGE TANK CONTROL -///////////////////////////////////////////////////////////// - -/obj/machinery/computer/atmos_control/tank - var/input_tag - var/output_tag - frequency = 1441 - circuit = /obj/item/circuitboard/computer/atmos_control/tank - - var/list/input_info - var/list/output_info - -// This hacky madness is the evidence of the fact that a lot of machines were never meant to be constructable, im so sorry you had to see this -/obj/machinery/computer/atmos_control/tank/proc/reconnect(mob/user) - var/list/IO = list() - var/datum/radio_frequency/freq = SSradio.return_frequency(1441) - var/list/devices = freq.devices["_default"] - for(var/obj/machinery/atmospherics/components/unary/vent_pump/U in devices) - var/list/text = splittext(U.id_tag, "_") - IO |= text[1] - for(var/obj/machinery/atmospherics/components/unary/outlet_injector/U in devices) - var/list/text = splittext(U.id, "_") - IO |= text[1] - if(!IO.len) - to_chat(user, "No machinery detected.") - var/S = input("Select the device set: ", "Selection", IO[1]) as anything in IO - if(src) - src.input_tag = "[S]_in" - src.output_tag = "[S]_out" - name = "[uppertext(S)] Supply Control" - var/list/new_devices = freq.devices["4"] - for(var/obj/machinery/air_sensor/U in new_devices) - var/list/text = splittext(U.id_tag, "_") - if(text[1] == S) - sensors = list("[S]_sensor" = "Tank") - break - - for(var/obj/machinery/atmospherics/components/unary/outlet_injector/U in devices) - U.broadcast_status() - for(var/obj/machinery/atmospherics/components/unary/vent_pump/U in devices) - U.broadcast_status() - + datum/tgui/master_ui = null, datum/ui_state/state = GLOB.default_state) + ui = SStgui.try_update_ui(user, src, ui_key, ui, force_open) + if(!ui) + ui = new(user, src, ui_key, "atmos_control", name, 400, 925, master_ui, state) + ui.open() + +/obj/machinery/computer/atmos_control/ui_data(mob/user) + var/data = list() + + data["sensors"] = list() + for(var/id_tag in sensors) + var/long_name = sensors[id_tag] + var/list/info = sensor_information[id_tag] + if(!info) + continue + data["sensors"] += list(list( + "id_tag" = id_tag, + "long_name" = sanitize(long_name), + "pressure" = info["pressure"], + "temperature" = info["temperature"], + "gases" = info["gases"] + )) + return data + +/obj/machinery/computer/atmos_control/receive_signal(datum/signal/signal) + if(!signal || signal.encryption) + return + + var/id_tag = signal.data["id_tag"] + if(!id_tag || !sensors.Find(id_tag)) + return + + sensor_information[id_tag] = signal.data + +/obj/machinery/computer/atmos_control/proc/set_frequency(new_frequency) + SSradio.remove_object(src, frequency) + frequency = new_frequency + radio_connection = SSradio.add_object(src, frequency, GLOB.RADIO_ATMOSIA) + +///////////////////////////////////////////////////////////// +// LARGE TANK CONTROL +///////////////////////////////////////////////////////////// + +/obj/machinery/computer/atmos_control/tank + var/input_tag + var/output_tag + frequency = 1441 + circuit = /obj/item/circuitboard/computer/atmos_control/tank + + var/list/input_info + var/list/output_info + +// This hacky madness is the evidence of the fact that a lot of machines were never meant to be constructable, im so sorry you had to see this +/obj/machinery/computer/atmos_control/tank/proc/reconnect(mob/user) + var/list/IO = list() + var/datum/radio_frequency/freq = SSradio.return_frequency(1441) + var/list/devices = freq.devices["_default"] + for(var/obj/machinery/atmospherics/components/unary/vent_pump/U in devices) + var/list/text = splittext(U.id_tag, "_") + IO |= text[1] + for(var/obj/machinery/atmospherics/components/unary/outlet_injector/U in devices) + var/list/text = splittext(U.id, "_") + IO |= text[1] + if(!IO.len) + to_chat(user, "No machinery detected.") + var/S = input("Select the device set: ", "Selection", IO[1]) as anything in IO + if(src) + src.input_tag = "[S]_in" + src.output_tag = "[S]_out" + name = "[uppertext(S)] Supply Control" + var/list/new_devices = freq.devices["4"] + for(var/obj/machinery/air_sensor/U in new_devices) + var/list/text = splittext(U.id_tag, "_") + if(text[1] == S) + sensors = list("[S]_sensor" = "Tank") + break + + for(var/obj/machinery/atmospherics/components/unary/outlet_injector/U in devices) + U.broadcast_status() + for(var/obj/machinery/atmospherics/components/unary/vent_pump/U in devices) + U.broadcast_status() + /obj/machinery/computer/atmos_control/tank/ui_interact(mob/user, ui_key = "main", datum/tgui/ui = null, force_open = FALSE, \ - datum/tgui/master_ui = null, datum/ui_state/state = GLOB.default_state) - ui = SStgui.try_update_ui(user, src, ui_key, ui, force_open) - if(!ui) - ui = new(user, src, ui_key, "atmos_control", name, 500, 305, master_ui, state) - ui.open() - -/obj/machinery/computer/atmos_control/tank/ui_data(mob/user) - var/list/data = ..() - data["tank"] = TRUE - data["inputting"] = input_info ? input_info["power"] : FALSE - data["inputRate"] = input_info ? input_info["volume_rate"] : 0 - data["outputting"] = output_info ? output_info["power"] : FALSE - data["outputPressure"] = output_info ? output_info["internal"] : 0 - - return data - -/obj/machinery/computer/atmos_control/tank/ui_act(action, params) - if(..() || !radio_connection) - return - var/datum/signal/signal = new - signal.transmission_method = 1 - signal.source = src - signal.data = list("sigtype" = "command") - switch(action) - if("reconnect") - reconnect(usr) - . = TRUE - if("input") - signal.data += list("tag" = input_tag, "power_toggle" = TRUE) - . = TRUE - if("output") - signal.data += list("tag" = output_tag, "power_toggle" = TRUE) - . = TRUE - if("pressure") - var/target = input("New target pressure:", name, output_info ? output_info["internal"] : 0) as num|null - if(!isnull(target) && !..()) - target = Clamp(target, 0, 50 * ONE_ATMOSPHERE) - signal.data += list("tag" = output_tag, "set_internal_pressure" = target) - . = TRUE - radio_connection.post_signal(src, signal, filter = GLOB.RADIO_ATMOSIA) - -/obj/machinery/computer/atmos_control/tank/receive_signal(datum/signal/signal) - if(!signal || signal.encryption) - return - - var/id_tag = signal.data["tag"] - - if(input_tag == id_tag) - input_info = signal.data - else if(output_tag == id_tag) - output_info = signal.data - else - ..(signal) + datum/tgui/master_ui = null, datum/ui_state/state = GLOB.default_state) + ui = SStgui.try_update_ui(user, src, ui_key, ui, force_open) + if(!ui) + ui = new(user, src, ui_key, "atmos_control", name, 500, 305, master_ui, state) + ui.open() + +/obj/machinery/computer/atmos_control/tank/ui_data(mob/user) + var/list/data = ..() + data["tank"] = TRUE + data["inputting"] = input_info ? input_info["power"] : FALSE + data["inputRate"] = input_info ? input_info["volume_rate"] : 0 + data["outputting"] = output_info ? output_info["power"] : FALSE + data["outputPressure"] = output_info ? output_info["internal"] : 0 + + return data + +/obj/machinery/computer/atmos_control/tank/ui_act(action, params) + if(..() || !radio_connection) + return + var/datum/signal/signal = new + signal.transmission_method = 1 + signal.source = src + signal.data = list("sigtype" = "command") + switch(action) + if("reconnect") + reconnect(usr) + . = TRUE + if("input") + signal.data += list("tag" = input_tag, "power_toggle" = TRUE) + . = TRUE + if("output") + signal.data += list("tag" = output_tag, "power_toggle" = TRUE) + . = TRUE + if("pressure") + var/target = input("New target pressure:", name, output_info ? output_info["internal"] : 0) as num|null + if(!isnull(target) && !..()) + target = Clamp(target, 0, 50 * ONE_ATMOSPHERE) + signal.data += list("tag" = output_tag, "set_internal_pressure" = target) + . = TRUE + radio_connection.post_signal(src, signal, filter = GLOB.RADIO_ATMOSIA) + +/obj/machinery/computer/atmos_control/tank/receive_signal(datum/signal/signal) + if(!signal || signal.encryption) + return + + var/id_tag = signal.data["tag"] + + if(input_tag == id_tag) + input_info = signal.data + else if(output_tag == id_tag) + output_info = signal.data + else + ..(signal)