@@ -1,31 +1,31 @@
|
||||
/obj/machinery/atmospherics/components/binary
|
||||
icon = 'icons/obj/atmospherics/components/binary_devices.dmi'
|
||||
dir = SOUTH
|
||||
initialize_directions = SOUTH|NORTH
|
||||
/obj/machinery/atmospherics/components/binary
|
||||
icon = 'icons/obj/atmospherics/components/binary_devices.dmi'
|
||||
dir = SOUTH
|
||||
initialize_directions = SOUTH|NORTH
|
||||
use_power = IDLE_POWER_USE
|
||||
device_type = BINARY
|
||||
device_type = BINARY
|
||||
layer = GAS_PUMP_LAYER
|
||||
|
||||
/obj/machinery/atmospherics/components/binary/SetInitDirections()
|
||||
switch(dir)
|
||||
if(NORTH)
|
||||
initialize_directions = NORTH|SOUTH
|
||||
if(SOUTH)
|
||||
initialize_directions = NORTH|SOUTH
|
||||
if(EAST)
|
||||
initialize_directions = EAST|WEST
|
||||
if(WEST)
|
||||
initialize_directions = EAST|WEST
|
||||
/*
|
||||
Iconnery
|
||||
*/
|
||||
/obj/machinery/atmospherics/components/binary/hide(intact)
|
||||
update_icon()
|
||||
|
||||
..(intact)
|
||||
/*
|
||||
Housekeeping and pipe network stuff
|
||||
*/
|
||||
|
||||
|
||||
/obj/machinery/atmospherics/components/binary/SetInitDirections()
|
||||
switch(dir)
|
||||
if(NORTH)
|
||||
initialize_directions = NORTH|SOUTH
|
||||
if(SOUTH)
|
||||
initialize_directions = NORTH|SOUTH
|
||||
if(EAST)
|
||||
initialize_directions = EAST|WEST
|
||||
if(WEST)
|
||||
initialize_directions = EAST|WEST
|
||||
/*
|
||||
Iconnery
|
||||
*/
|
||||
/obj/machinery/atmospherics/components/binary/hide(intact)
|
||||
update_icon()
|
||||
|
||||
..(intact)
|
||||
/*
|
||||
Housekeeping and pipe network stuff
|
||||
*/
|
||||
|
||||
/obj/machinery/atmospherics/components/binary/getNodeConnects()
|
||||
return list(turn(dir, 180), dir)
|
||||
|
||||
@@ -32,6 +32,10 @@ Acts like a normal vent, but has an input AND output.
|
||||
//INPUT_MIN: Do not pass input_pressure_min
|
||||
//OUTPUT_MAX: Do not pass output_pressure_max
|
||||
|
||||
/obj/machinery/atmospherics/components/binary/dp_vent_pump/on
|
||||
on = TRUE
|
||||
icon_state = "dpvent_map_on"
|
||||
|
||||
/obj/machinery/atmospherics/components/binary/dp_vent_pump/Destroy()
|
||||
if(SSradio)
|
||||
SSradio.remove_object(src, frequency)
|
||||
@@ -40,6 +44,10 @@ Acts like a normal vent, but has an input AND output.
|
||||
/obj/machinery/atmospherics/components/binary/dp_vent_pump/high_volume
|
||||
name = "large dual-port air vent"
|
||||
|
||||
/obj/machinery/atmospherics/components/binary/dp_vent_pump/high_volume/on
|
||||
on = TRUE
|
||||
icon_state = "dpvent_map_on"
|
||||
|
||||
/obj/machinery/atmospherics/components/binary/dp_vent_pump/high_volume/New()
|
||||
..()
|
||||
var/datum/gas_mixture/air1 = AIR1
|
||||
|
||||
Reference in New Issue