Maptick lag minimization port (#12066)

* extools.dll

* backend

* queued pipenet builds

* oh yeah we don't have that

* wow

* Update air.dm
This commit is contained in:
kevinz000
2020-05-02 18:34:33 -07:00
committed by GitHub
parent 5bf7fd0030
commit c1436c4c7b
17 changed files with 87 additions and 42 deletions
+20 -12
View File
@@ -1,11 +1,3 @@
#define SSAIR_PIPENETS 1
#define SSAIR_ATMOSMACHINERY 2
#define SSAIR_REACTQUEUE 3
#define SSAIR_EXCITEDGROUPS 4
#define SSAIR_HIGHPRESSURE 5
#define SSAIR_HOTSPOTS 6
#define SSAIR_SUPERCONDUCTIVITY 7
SUBSYSTEM_DEF(air)
name = "Atmospherics"
init_order = INIT_ORDER_AIR
@@ -20,6 +12,7 @@ SUBSYSTEM_DEF(air)
var/cost_hotspots = 0
var/cost_superconductivity = 0
var/cost_pipenets = 0
var/cost_rebuilds = 0
var/cost_atmos_machinery = 0
var/list/excited_groups = list()
@@ -27,6 +20,7 @@ SUBSYSTEM_DEF(air)
var/list/turf_react_queue = list()
var/list/hotspots = list()
var/list/networks = list()
var/list/pipenets_needing_rebuilt = list()
var/list/obj/machinery/atmos_machinery = list()
var/list/pipe_init_dirs_cache = list()
@@ -39,7 +33,7 @@ SUBSYSTEM_DEF(air)
var/list/currentrun = list()
var/currentpart = SSAIR_PIPENETS
var/currentpart = SSAIR_REBUILD_PIPENETS
var/map_loading = TRUE
var/list/queued_for_activation
@@ -52,6 +46,7 @@ SUBSYSTEM_DEF(air)
msg += "HS:[round(cost_hotspots,1)]|"
msg += "SC:[round(cost_superconductivity,1)]|"
msg += "PN:[round(cost_pipenets,1)]|"
msg += "RB:[round(cost_rebuilds,1)]|"
msg += "AM:[round(cost_atmos_machinery,1)]"
msg += "} "
msg += "AT:[active_turfs.len]|"
@@ -77,6 +72,18 @@ SUBSYSTEM_DEF(air)
/datum/controller/subsystem/air/fire(resumed = 0)
var/timer = TICK_USAGE_REAL
if(currentpart == SSAIR_REBUILD_PIPENETS)
var/list/pipenet_rebuilds = pipenets_needing_rebuilt
for(var/thing in pipenet_rebuilds)
var/obj/machinery/atmospherics/AT = thing
AT.build_network()
cost_rebuilds = MC_AVERAGE(cost_rebuilds, TICK_DELTA_TO_MS(TICK_USAGE_REAL - timer))
pipenets_needing_rebuilt.Cut()
if(state != SS_RUNNING)
return
resumed = FALSE
currentpart = SSAIR_PIPENETS
if(currentpart == SSAIR_PIPENETS || !resumed)
process_pipenets(resumed)
cost_pipenets = MC_AVERAGE(cost_pipenets, TICK_DELTA_TO_MS(TICK_USAGE_REAL - timer))
@@ -137,9 +144,7 @@ SUBSYSTEM_DEF(air)
if(state != SS_RUNNING)
return
resumed = 0
currentpart = SSAIR_PIPENETS
currentpart = SSAIR_REBUILD_PIPENETS
/datum/controller/subsystem/air/proc/process_pipenets(resumed = 0)
if (!resumed)
@@ -156,6 +161,9 @@ SUBSYSTEM_DEF(air)
if(MC_TICK_CHECK)
return
/datum/controller/subsystem/air/proc/add_to_rebuild_queue(atmos_machine)
if(istype(atmos_machine, /obj/machinery/atmospherics))
pipenets_needing_rebuilt += atmos_machine
/datum/controller/subsystem/air/proc/process_atmos_machinery(resumed = 0)
var/seconds = wait * 0.1