This commit is contained in:
Putnam
2021-03-08 14:46:46 -08:00
760 changed files with 31912 additions and 23386 deletions
@@ -55,26 +55,7 @@ Passive gate is similar to the regular pump except:
var/datum/gas_mixture/air1 = airs[1]
var/datum/gas_mixture/air2 = airs[2]
var/output_starting_pressure = air2.return_pressure()
var/input_starting_pressure = air1.return_pressure()
if(output_starting_pressure >= min(target_pressure,input_starting_pressure-10))
//No need to pump gas if target is already reached or input pressure is too low
//Need at least 10 KPa difference to overcome friction in the mechanism
return
//Calculate necessary moles to transfer using PV = nRT
if((air1.total_moles() > 0) && (air1.return_temperature()>0))
var/pressure_delta = min(target_pressure - output_starting_pressure, (input_starting_pressure - output_starting_pressure)/2)
//Can not have a pressure delta that would cause output_pressure > input_pressure
var/transfer_moles = pressure_delta*air2.return_volume()/(air1.return_temperature() * R_IDEAL_GAS_EQUATION)
//Actually transfer the gas
var/datum/gas_mixture/removed = air1.remove(transfer_moles)
air2.merge(removed)
if(release_gas_to(air1, air2, target_pressure))
update_parents()