initial commit - game folder + maps + dme
This commit is contained in:
@@ -17,7 +17,7 @@
|
||||
var/target_state = AIRLOCK_STATE_CLOSED
|
||||
var/sensor_pressure = null
|
||||
|
||||
/datum/computer/file/embedded_program/airlock_controller/receive_signal(datum/signal/signal, receive_method, receive_param)
|
||||
/datum/computer/file/embedded_program/airlock_controller/receive_signal(datum/signal/signal)
|
||||
var/receive_tag = signal.data["tag"]
|
||||
if(!receive_tag)
|
||||
return
|
||||
@@ -68,19 +68,17 @@
|
||||
state = AIRLOCK_STATE_CLOSED
|
||||
process_again = 1
|
||||
else
|
||||
var/datum/signal/signal = new
|
||||
signal.data["tag"] = interior_door_tag
|
||||
signal.data["command"] = "secure_close"
|
||||
post_signal(signal)
|
||||
post_signal(new /datum/signal(list(
|
||||
"tag" = interior_door_tag,
|
||||
"command" = "secure_close"
|
||||
)))
|
||||
else
|
||||
if(memory["pump_status"] != "off")
|
||||
var/datum/signal/signal = new
|
||||
signal.data = list(
|
||||
post_signal(new /datum/signal(list(
|
||||
"tag" = airpump_tag,
|
||||
"power" = 0,
|
||||
"sigtype"="command"
|
||||
)
|
||||
post_signal(signal)
|
||||
"sigtype" = "command"
|
||||
)))
|
||||
|
||||
if(AIRLOCK_STATE_PRESSURIZE)
|
||||
if(target_state < state)
|
||||
@@ -89,16 +87,15 @@
|
||||
state = AIRLOCK_STATE_INOPEN
|
||||
process_again = 1
|
||||
else
|
||||
var/datum/signal/signal = new
|
||||
signal.data["tag"] = interior_door_tag
|
||||
signal.data["command"] = "secure_open"
|
||||
post_signal(signal)
|
||||
post_signal(new /datum/signal(list(
|
||||
"tag" = interior_door_tag,
|
||||
"command" = "secure_open"
|
||||
)))
|
||||
else
|
||||
var/datum/signal/signal = new
|
||||
signal.data = list(
|
||||
var/datum/signal/signal = new(list(
|
||||
"tag" = airpump_tag,
|
||||
"sigtype"="command"
|
||||
)
|
||||
"sigtype" = "command"
|
||||
))
|
||||
if(memory["pump_status"] == "siphon")
|
||||
signal.data["stabalize"] = 1
|
||||
else if(memory["pump_status"] != "release")
|
||||
@@ -114,29 +111,27 @@
|
||||
state = AIRLOCK_STATE_DEPRESSURIZE
|
||||
process_again = 1
|
||||
else
|
||||
var/datum/signal/signal = new
|
||||
signal.data["tag"] = interior_door_tag
|
||||
signal.data["command"] = "secure_close"
|
||||
post_signal(signal)
|
||||
post_signal(new /datum/signal(list(
|
||||
"tag" = interior_door_tag,
|
||||
"command" = "secure_close"
|
||||
)))
|
||||
else if(target_state < state)
|
||||
if(memory["exterior_status"] == "closed")
|
||||
state = AIRLOCK_STATE_PRESSURIZE
|
||||
process_again = 1
|
||||
else
|
||||
var/datum/signal/signal = new
|
||||
signal.data["tag"] = exterior_door_tag
|
||||
signal.data["command"] = "secure_close"
|
||||
post_signal(signal)
|
||||
post_signal(new /datum/signal(list(
|
||||
"tag" = exterior_door_tag,
|
||||
"command" = "secure_close"
|
||||
)))
|
||||
|
||||
else
|
||||
if(memory["pump_status"] != "off")
|
||||
var/datum/signal/signal = new
|
||||
signal.data = list(
|
||||
post_signal(new /datum/signal(list(
|
||||
"tag" = airpump_tag,
|
||||
"power" = 0,
|
||||
"sigtype"="command"
|
||||
)
|
||||
post_signal(signal)
|
||||
"sigtype" = "command"
|
||||
)))
|
||||
|
||||
if(AIRLOCK_STATE_DEPRESSURIZE)
|
||||
var/target_pressure = ONE_ATMOSPHERE*0.05
|
||||
@@ -148,10 +143,10 @@
|
||||
if(memory["exterior_status"] == "open")
|
||||
state = AIRLOCK_STATE_OUTOPEN
|
||||
else
|
||||
var/datum/signal/signal = new
|
||||
signal.data["tag"] = exterior_door_tag
|
||||
signal.data["command"] = "secure_open"
|
||||
post_signal(signal)
|
||||
post_signal(new /datum/signal(list(
|
||||
"tag" = exterior_door_tag,
|
||||
"command" = "secure_open"
|
||||
)))
|
||||
else if(target_state < state)
|
||||
state = AIRLOCK_STATE_CLOSED
|
||||
process_again = 1
|
||||
@@ -159,12 +154,10 @@
|
||||
state = AIRLOCK_STATE_CLOSED
|
||||
process_again = 1
|
||||
else
|
||||
var/datum/signal/signal = new
|
||||
signal.transmission_method = 1 //radio signal
|
||||
signal.data = list(
|
||||
var/datum/signal/signal = new(list(
|
||||
"tag" = airpump_tag,
|
||||
"sigtype"="command"
|
||||
)
|
||||
"sigtype" = "command"
|
||||
))
|
||||
if(memory["pump_status"] == "release")
|
||||
signal.data["purge"] = 1
|
||||
else if(memory["pump_status"] != "siphon")
|
||||
@@ -181,19 +174,17 @@
|
||||
state = AIRLOCK_STATE_CLOSED
|
||||
process_again = 1
|
||||
else
|
||||
var/datum/signal/signal = new
|
||||
signal.data["tag"] = exterior_door_tag
|
||||
signal.data["command"] = "secure_close"
|
||||
post_signal(signal)
|
||||
post_signal(new /datum/signal(list(
|
||||
"tag" = exterior_door_tag,
|
||||
"command" = "secure_close"
|
||||
)))
|
||||
else
|
||||
if(memory["pump_status"] != "off")
|
||||
var/datum/signal/signal = new
|
||||
signal.data = list(
|
||||
post_signal(new /datum/signal(list(
|
||||
"tag" = airpump_tag,
|
||||
"power" = 0,
|
||||
"sigtype"="command"
|
||||
)
|
||||
post_signal(signal)
|
||||
"sigtype" = "command"
|
||||
)))
|
||||
|
||||
memory["sensor_pressure"] = sensor_pressure
|
||||
memory["processing"] = state != target_state
|
||||
@@ -209,7 +200,7 @@
|
||||
name = "airlock console"
|
||||
density = FALSE
|
||||
|
||||
frequency = 1449
|
||||
frequency = FREQ_AIRLOCK_CONTROL
|
||||
power_channel = ENVIRON
|
||||
|
||||
// Setup parameters only
|
||||
@@ -293,4 +284,4 @@
|
||||
</div>
|
||||
[state_options]"}
|
||||
|
||||
return output
|
||||
return output
|
||||
Reference in New Issue