Merge branch 'master' into upstream-merge-33621

This commit is contained in:
LetterJay
2017-12-30 13:23:39 -06:00
committed by GitHub
798 changed files with 12704 additions and 27419 deletions
@@ -185,13 +185,13 @@ Acts like a normal vent, but has an input AND output.
pump_direction = 1
if("set_input_pressure" in signal.data)
input_pressure_min = Clamp(text2num(signal.data["set_input_pressure"]),0,ONE_ATMOSPHERE*50)
input_pressure_min = CLAMP(text2num(signal.data["set_input_pressure"]),0,ONE_ATMOSPHERE*50)
if("set_output_pressure" in signal.data)
output_pressure_max = Clamp(text2num(signal.data["set_output_pressure"]),0,ONE_ATMOSPHERE*50)
output_pressure_max = CLAMP(text2num(signal.data["set_output_pressure"]),0,ONE_ATMOSPHERE*50)
if("set_external_pressure" in signal.data)
external_pressure_bound = Clamp(text2num(signal.data["set_external_pressure"]),0,ONE_ATMOSPHERE*50)
external_pressure_bound = CLAMP(text2num(signal.data["set_external_pressure"]),0,ONE_ATMOSPHERE*50)
if("status" in signal.data)
spawn(2)
@@ -127,7 +127,7 @@ Passive gate is similar to the regular pump except:
pressure = text2num(pressure)
. = TRUE
if(.)
target_pressure = Clamp(pressure, 0, MAX_OUTPUT_PRESSURE)
target_pressure = CLAMP(pressure, 0, MAX_OUTPUT_PRESSURE)
investigate_log("was set to [target_pressure] kPa by [key_name(usr)]", INVESTIGATE_ATMOS)
update_icon()
@@ -149,7 +149,7 @@ Passive gate is similar to the regular pump except:
on = !on
if("set_output_pressure" in signal.data)
target_pressure = Clamp(text2num(signal.data["set_output_pressure"]),0,ONE_ATMOSPHERE*50)
target_pressure = CLAMP(text2num(signal.data["set_output_pressure"]),0,ONE_ATMOSPHERE*50)
if(on != old_on)
investigate_log("was turned [on ? "on" : "off"] by a remote signal", INVESTIGATE_ATMOS)
@@ -133,9 +133,8 @@ Thus, the two variables affect pump operation are set in New():
pressure = text2num(pressure)
. = TRUE
if(.)
target_pressure = Clamp(pressure, 0, MAX_OUTPUT_PRESSURE)
investigate_log("Pump, [src.name], was set to [target_pressure] kPa by [key_name(usr)] at [x], [y], [z], [A]", INVESTIGATE_ATMOS)
message_admins("Pump, [src.name], was set to [target_pressure] kPa by [ADMIN_LOOKUPFLW(usr)] at [ADMIN_COORDJMP(T)], [A]")
target_pressure = CLAMP(pressure, 0, MAX_OUTPUT_PRESSURE)
investigate_log("was set to [target_pressure] kPa by [key_name(usr)]", INVESTIGATE_ATMOS)
update_icon()
/obj/machinery/atmospherics/components/binary/pump/atmosinit()
@@ -156,7 +155,7 @@ Thus, the two variables affect pump operation are set in New():
on = !on
if("set_output_pressure" in signal.data)
target_pressure = Clamp(text2num(signal.data["set_output_pressure"]),0,ONE_ATMOSPHERE*50)
target_pressure = CLAMP(text2num(signal.data["set_output_pressure"]),0,ONE_ATMOSPHERE*50)
if(on != old_on)
investigate_log("was turned [on ? "on" : "off"] by a remote signal", INVESTIGATE_ATMOS)
@@ -133,9 +133,8 @@ Thus, the two variables affect pump operation are set in New():
rate = text2num(rate)
. = TRUE
if(.)
transfer_rate = Clamp(rate, 0, MAX_TRANSFER_RATE)
investigate_log("Volume Pump, [src.name], was set to [transfer_rate] L/s by [key_name(usr)] at [x], [y], [z], [A]", INVESTIGATE_ATMOS)
message_admins("Volume Pump, [src.name], was set to [transfer_rate] L/s by [ADMIN_LOOKUPFLW(usr)] at [ADMIN_COORDJMP(T)], [A]")
transfer_rate = CLAMP(rate, 0, MAX_TRANSFER_RATE)
investigate_log("was set to [transfer_rate] L/s by [key_name(usr)]", INVESTIGATE_ATMOS)
update_icon()
/obj/machinery/atmospherics/components/binary/volume_pump/receive_signal(datum/signal/signal)