Merge pull request #6662 from Citadel-Station-13/upstream-merge-37648
[MIRROR] Moves removing the cell to screwdriver_act for APCs
This commit is contained in:
+31
-26
@@ -34,6 +34,10 @@
|
||||
#define APC_COVER_OPENED 1
|
||||
#define APC_COVER_REMOVED 2
|
||||
|
||||
#define APC_NOT_CHARGING 0
|
||||
#define APC_CHARGING 1
|
||||
#define APC_FULLY_CHARGED 2
|
||||
|
||||
// the Area Power Controller (APC), formerly Power Distribution Unit (PDU)
|
||||
// one per area, needs wire connection to power network through a terminal
|
||||
|
||||
@@ -66,7 +70,7 @@
|
||||
var/equipment = 3
|
||||
var/environ = 3
|
||||
var/operating = TRUE
|
||||
var/charging = 0
|
||||
var/charging = APC_NOT_CHARGING
|
||||
var/chargemode = 1
|
||||
var/chargecount = 0
|
||||
var/locked = TRUE
|
||||
@@ -291,11 +295,11 @@
|
||||
// And now, separately for cleanness, the lighting changing
|
||||
if(update_state & UPSTATE_ALLGOOD)
|
||||
switch(charging)
|
||||
if(0)
|
||||
if(APC_NOT_CHARGING)
|
||||
light_color = LIGHT_COLOR_RED
|
||||
if(1)
|
||||
if(APC_CHARGING)
|
||||
light_color = LIGHT_COLOR_BLUE
|
||||
if(2)
|
||||
if(APC_FULLY_CHARGED)
|
||||
light_color = LIGHT_COLOR_GREEN
|
||||
set_light(lon_range)
|
||||
else if(update_state & UPSTATE_BLUESCREEN)
|
||||
@@ -339,9 +343,9 @@
|
||||
|
||||
if(!charging)
|
||||
update_overlay |= APC_UPOVERLAY_CHARGEING0
|
||||
else if(charging == 1)
|
||||
else if(charging == APC_CHARGING)
|
||||
update_overlay |= APC_UPOVERLAY_CHARGEING1
|
||||
else if(charging == 2)
|
||||
else if(charging == APC_FULLY_CHARGED)
|
||||
update_overlay |= APC_UPOVERLAY_CHARGEING2
|
||||
|
||||
if (!equipment)
|
||||
@@ -384,15 +388,6 @@
|
||||
/obj/machinery/power/apc/crowbar_act(mob/user, obj/item/W)
|
||||
. = TRUE
|
||||
if (opened)
|
||||
if(cell)
|
||||
user.visible_message("[user] removes \the [cell] from [src]!","<span class='notice'>You remove \the [cell].</span>")
|
||||
var/turf/T = get_turf(user)
|
||||
cell.forceMove(T)
|
||||
cell.update_icon()
|
||||
cell = null
|
||||
charging = 0
|
||||
update_icon()
|
||||
return
|
||||
if (has_electronics == APC_ELECTRONICS_INSTALLED)
|
||||
if (terminal)
|
||||
to_chat(user, "<span class='warning'>Disconnect the wires first!</span>")
|
||||
@@ -457,8 +452,14 @@
|
||||
/obj/machinery/power/apc/screwdriver_act(mob/living/user, obj/item/W)
|
||||
. = TRUE
|
||||
if(opened)
|
||||
if (cell)
|
||||
to_chat(user, "<span class='warning'>Close the APC first!</span>")
|
||||
if(cell)
|
||||
user.visible_message("[user] removes \the [cell] from [src]!","<span class='notice'>You remove \the [cell].</span>")
|
||||
var/turf/T = get_turf(user)
|
||||
cell.forceMove(T)
|
||||
cell.update_icon()
|
||||
cell = null
|
||||
charging = APC_NOT_CHARGING
|
||||
update_icon()
|
||||
return
|
||||
else
|
||||
switch (has_electronics)
|
||||
@@ -745,7 +746,7 @@
|
||||
user.put_in_hands(cell)
|
||||
cell.update_icon()
|
||||
src.cell = null
|
||||
charging = 0
|
||||
charging = APC_NOT_CHARGING
|
||||
src.update_icon()
|
||||
return
|
||||
if((stat & MAINT) && !opened) //no board; no interface
|
||||
@@ -888,7 +889,7 @@
|
||||
if("charge")
|
||||
chargemode = !chargemode
|
||||
if(!chargemode)
|
||||
charging = 0
|
||||
charging = APC_NOT_CHARGING
|
||||
update_icon()
|
||||
. = TRUE
|
||||
if("channel")
|
||||
@@ -1125,10 +1126,10 @@
|
||||
if((cell.charge/GLOB.CELLRATE + excess) >= lastused_total) // can we draw enough from cell+grid to cover last usage?
|
||||
cell.charge = min(cell.maxcharge, cell.charge + GLOB.CELLRATE * excess) //recharge with what we can
|
||||
add_load(excess) // so draw what we can from the grid
|
||||
charging = 0
|
||||
charging = APC_NOT_CHARGING
|
||||
|
||||
else // not enough power available to run the last tick!
|
||||
charging = 0
|
||||
charging = APC_NOT_CHARGING
|
||||
chargecount = 0
|
||||
// This turns everything off in the case that there is still a charge left on the battery, just not enough to run the room.
|
||||
equipment = autoset(equipment, 0)
|
||||
@@ -1168,7 +1169,7 @@
|
||||
area.poweralert(1, src)
|
||||
|
||||
// now trickle-charge the cell
|
||||
if(chargemode && charging == 1 && operating)
|
||||
if(chargemode && charging == APC_CHARGING && operating)
|
||||
if(excess > 0) // check to make sure we have enough to charge
|
||||
// Max charge is capped to % per second constant
|
||||
var/ch = min(excess*GLOB.CELLRATE, cell.maxcharge*GLOB.CHARGELEVEL)
|
||||
@@ -1176,13 +1177,13 @@
|
||||
cell.give(ch) // actually recharge the cell
|
||||
|
||||
else
|
||||
charging = 0 // stop charging
|
||||
charging = APC_NOT_CHARGING // stop charging
|
||||
chargecount = 0
|
||||
|
||||
// show cell as fully charged if so
|
||||
if(cell.charge >= cell.maxcharge)
|
||||
cell.charge = cell.maxcharge
|
||||
charging = 2
|
||||
charging = APC_FULLY_CHARGED
|
||||
|
||||
if(chargemode)
|
||||
if(!charging)
|
||||
@@ -1194,7 +1195,7 @@
|
||||
if(chargecount == 10)
|
||||
|
||||
chargecount = 0
|
||||
charging = 1
|
||||
charging = APC_CHARGING
|
||||
|
||||
else // chargemode off
|
||||
charging = 0
|
||||
@@ -1202,7 +1203,7 @@
|
||||
|
||||
else // no cell, switch everything off
|
||||
|
||||
charging = 0
|
||||
charging = APC_NOT_CHARGING
|
||||
chargecount = 0
|
||||
equipment = autoset(equipment, 0)
|
||||
lighting = autoset(lighting, 0)
|
||||
@@ -1358,6 +1359,10 @@
|
||||
#undef APC_COVER_OPENED
|
||||
#undef APC_COVER_REMOVED
|
||||
|
||||
#undef APC_NOT_CHARGING
|
||||
#undef APC_CHARGING
|
||||
#undef APC_FULLY_CHARGED
|
||||
|
||||
//update_overlay
|
||||
#undef APC_UPOVERLAY_CHARGEING0
|
||||
#undef APC_UPOVERLAY_CHARGEING1
|
||||
|
||||
Reference in New Issue