Defines math, take 2

This commit is contained in:
Emmett Gaines
2017-12-17 11:02:11 -05:00
committed by CitadelStationBot
parent 220e1cd8cf
commit f875d4e176
180 changed files with 1250 additions and 644 deletions
@@ -185,13 +185,13 @@ Acts like a normal vent, but has an input AND output.
pump_direction = 1
if("set_input_pressure" in signal.data)
input_pressure_min = Clamp(text2num(signal.data["set_input_pressure"]),0,ONE_ATMOSPHERE*50)
input_pressure_min = CLAMP(text2num(signal.data["set_input_pressure"]),0,ONE_ATMOSPHERE*50)
if("set_output_pressure" in signal.data)
output_pressure_max = Clamp(text2num(signal.data["set_output_pressure"]),0,ONE_ATMOSPHERE*50)
output_pressure_max = CLAMP(text2num(signal.data["set_output_pressure"]),0,ONE_ATMOSPHERE*50)
if("set_external_pressure" in signal.data)
external_pressure_bound = Clamp(text2num(signal.data["set_external_pressure"]),0,ONE_ATMOSPHERE*50)
external_pressure_bound = CLAMP(text2num(signal.data["set_external_pressure"]),0,ONE_ATMOSPHERE*50)
if("status" in signal.data)
spawn(2)
@@ -127,7 +127,7 @@ Passive gate is similar to the regular pump except:
pressure = text2num(pressure)
. = TRUE
if(.)
target_pressure = Clamp(pressure, 0, MAX_OUTPUT_PRESSURE)
target_pressure = CLAMP(pressure, 0, MAX_OUTPUT_PRESSURE)
investigate_log("was set to [target_pressure] kPa by [key_name(usr)]", INVESTIGATE_ATMOS)
update_icon()
@@ -149,7 +149,7 @@ Passive gate is similar to the regular pump except:
on = !on
if("set_output_pressure" in signal.data)
target_pressure = Clamp(text2num(signal.data["set_output_pressure"]),0,ONE_ATMOSPHERE*50)
target_pressure = CLAMP(text2num(signal.data["set_output_pressure"]),0,ONE_ATMOSPHERE*50)
if(on != old_on)
investigate_log("was turned [on ? "on" : "off"] by a remote signal", INVESTIGATE_ATMOS)
@@ -133,9 +133,14 @@ Thus, the two variables affect pump operation are set in New():
pressure = text2num(pressure)
. = TRUE
if(.)
<<<<<<< HEAD
target_pressure = Clamp(pressure, 0, MAX_OUTPUT_PRESSURE)
investigate_log("Pump, [src.name], was set to [target_pressure] kPa by [key_name(usr)] at [x], [y], [z], [A]", INVESTIGATE_ATMOS)
message_admins("Pump, [src.name], was set to [target_pressure] kPa by [ADMIN_LOOKUPFLW(usr)] at [ADMIN_COORDJMP(T)], [A]")
=======
target_pressure = CLAMP(pressure, 0, MAX_OUTPUT_PRESSURE)
investigate_log("was set to [target_pressure] kPa by [key_name(usr)]", INVESTIGATE_ATMOS)
>>>>>>> 25080ff... defines math (#33498)
update_icon()
/obj/machinery/atmospherics/components/binary/pump/atmosinit()
@@ -156,7 +161,7 @@ Thus, the two variables affect pump operation are set in New():
on = !on
if("set_output_pressure" in signal.data)
target_pressure = Clamp(text2num(signal.data["set_output_pressure"]),0,ONE_ATMOSPHERE*50)
target_pressure = CLAMP(text2num(signal.data["set_output_pressure"]),0,ONE_ATMOSPHERE*50)
if(on != old_on)
investigate_log("was turned [on ? "on" : "off"] by a remote signal", INVESTIGATE_ATMOS)
@@ -133,9 +133,14 @@ Thus, the two variables affect pump operation are set in New():
rate = text2num(rate)
. = TRUE
if(.)
<<<<<<< HEAD
transfer_rate = Clamp(rate, 0, MAX_TRANSFER_RATE)
investigate_log("Volume Pump, [src.name], was set to [transfer_rate] L/s by [key_name(usr)] at [x], [y], [z], [A]", INVESTIGATE_ATMOS)
message_admins("Volume Pump, [src.name], was set to [transfer_rate] L/s by [ADMIN_LOOKUPFLW(usr)] at [ADMIN_COORDJMP(T)], [A]")
=======
transfer_rate = CLAMP(rate, 0, MAX_TRANSFER_RATE)
investigate_log("was set to [transfer_rate] L/s by [key_name(usr)]", INVESTIGATE_ATMOS)
>>>>>>> 25080ff... defines math (#33498)
update_icon()
/obj/machinery/atmospherics/components/binary/volume_pump/receive_signal(datum/signal/signal)
@@ -152,7 +157,7 @@ Thus, the two variables affect pump operation are set in New():
if("set_transfer_rate" in signal.data)
var/datum/gas_mixture/air1 = AIR1
transfer_rate = Clamp(text2num(signal.data["set_transfer_rate"]),0,air1.volume)
transfer_rate = CLAMP(text2num(signal.data["set_transfer_rate"]),0,air1.volume)
if(on != old_on)
investigate_log("was turned [on ? "on" : "off"] by a remote signal", INVESTIGATE_ATMOS)
@@ -162,7 +162,7 @@
pressure = text2num(pressure)
. = TRUE
if(.)
target_pressure = Clamp(pressure, 0, MAX_OUTPUT_PRESSURE)
target_pressure = CLAMP(pressure, 0, MAX_OUTPUT_PRESSURE)
investigate_log("was set to [target_pressure] kPa by [key_name(usr)]", INVESTIGATE_ATMOS)
if("filter")
filter_type = null
@@ -152,7 +152,7 @@
pressure = text2num(pressure)
. = TRUE
if(.)
target_pressure = Clamp(pressure, 0, MAX_OUTPUT_PRESSURE)
target_pressure = CLAMP(pressure, 0, MAX_OUTPUT_PRESSURE)
investigate_log("was set to [target_pressure] kPa by [key_name(usr)]", INVESTIGATE_ATMOS)
if("node1")
var/value = text2num(params["concentration"])
@@ -131,7 +131,7 @@
if("set_volume_rate" in signal.data)
var/number = text2num(signal.data["set_volume_rate"])
var/datum/gas_mixture/air_contents = AIR1
volume_rate = Clamp(number, 0, air_contents.volume)
volume_rate = CLAMP(number, 0, air_contents.volume)
if("status" in signal.data)
spawn(2)
@@ -180,7 +180,7 @@
rate = text2num(rate)
. = TRUE
if(.)
volume_rate = Clamp(rate, 0, MAX_TRANSFER_RATE)
volume_rate = CLAMP(rate, 0, MAX_TRANSFER_RATE)
investigate_log("was set to [volume_rate] L/s by [key_name(usr)]", INVESTIGATE_ATMOS)
update_icon()
broadcast_status()
@@ -153,7 +153,7 @@
target = text2num(target)
. = TRUE
if(.)
target_temperature = Clamp(target, min_temperature, max_temperature)
target_temperature = CLAMP(target, min_temperature, max_temperature)
investigate_log("was set to [target_temperature] K by [key_name(usr)]", INVESTIGATE_ATMOS)
update_icon()
@@ -244,10 +244,10 @@
pump_direction = text2num(signal.data["direction"])
if("set_internal_pressure" in signal.data)
internal_pressure_bound = Clamp(text2num(signal.data["set_internal_pressure"]),0,ONE_ATMOSPHERE*50)
internal_pressure_bound = CLAMP(text2num(signal.data["set_internal_pressure"]),0,ONE_ATMOSPHERE*50)
if("set_external_pressure" in signal.data)
external_pressure_bound = Clamp(text2num(signal.data["set_external_pressure"]),0,ONE_ATMOSPHERE*50)
external_pressure_bound = CLAMP(text2num(signal.data["set_external_pressure"]),0,ONE_ATMOSPHERE*50)
if("reset_external_pressure" in signal.data)
external_pressure_bound = ONE_ATMOSPHERE
@@ -256,10 +256,10 @@
internal_pressure_bound = 0
if("adjust_internal_pressure" in signal.data)
internal_pressure_bound = Clamp(internal_pressure_bound + text2num(signal.data["adjust_internal_pressure"]),0,ONE_ATMOSPHERE*50)
internal_pressure_bound = CLAMP(internal_pressure_bound + text2num(signal.data["adjust_internal_pressure"]),0,ONE_ATMOSPHERE*50)
if("adjust_external_pressure" in signal.data)
external_pressure_bound = Clamp(external_pressure_bound + text2num(signal.data["adjust_external_pressure"]),0,ONE_ATMOSPHERE*50)
external_pressure_bound = CLAMP(external_pressure_bound + text2num(signal.data["adjust_external_pressure"]),0,ONE_ATMOSPHERE*50)
if("init" in signal.data)
name = signal.data["init"]
@@ -121,7 +121,7 @@
if(initialize_directions & dir)
return ..()
if((NORTH|EAST) & dir)
user.ventcrawl_layer = Clamp(user.ventcrawl_layer + 1, PIPING_LAYER_MIN, PIPING_LAYER_MAX)
user.ventcrawl_layer = CLAMP(user.ventcrawl_layer + 1, PIPING_LAYER_MIN, PIPING_LAYER_MAX)
if((SOUTH|WEST) & dir)
user.ventcrawl_layer = Clamp(user.ventcrawl_layer - 1, PIPING_LAYER_MIN, PIPING_LAYER_MAX)
user.ventcrawl_layer = CLAMP(user.ventcrawl_layer - 1, PIPING_LAYER_MIN, PIPING_LAYER_MAX)
to_chat(user, "You align yourself with the [user.ventcrawl_layer]\th output.")
@@ -411,7 +411,7 @@
pressure = text2num(pressure)
. = TRUE
if(.)
release_pressure = Clamp(round(pressure), can_min_release_pressure, can_max_release_pressure)
release_pressure = CLAMP(round(pressure), can_min_release_pressure, can_max_release_pressure)
investigate_log("was set to [release_pressure] kPa by [key_name(usr)].", INVESTIGATE_ATMOS)
if("valve")
var/logmsg
@@ -455,7 +455,7 @@
var/N = text2num(user_input)
if(!N)
return
timer_set = Clamp(N,minimum_timer_set,maximum_timer_set)
timer_set = CLAMP(N,minimum_timer_set,maximum_timer_set)
log_admin("[key_name(usr)] has activated a prototype valve timer")
. = TRUE
if("toggle_timer")
@@ -131,7 +131,7 @@
pressure = text2num(pressure)
. = TRUE
if(.)
pump.target_pressure = Clamp(round(pressure), PUMP_MIN_PRESSURE, PUMP_MAX_PRESSURE)
pump.target_pressure = CLAMP(round(pressure), PUMP_MIN_PRESSURE, PUMP_MAX_PRESSURE)
investigate_log("was set to [pump.target_pressure] kPa by [key_name(usr)].", INVESTIGATE_ATMOS)
if("eject")
if(holding)