Defines math, take 2
This commit is contained in:
committed by
CitadelStationBot
parent
220e1cd8cf
commit
f875d4e176
@@ -185,13 +185,13 @@ Acts like a normal vent, but has an input AND output.
|
||||
pump_direction = 1
|
||||
|
||||
if("set_input_pressure" in signal.data)
|
||||
input_pressure_min = Clamp(text2num(signal.data["set_input_pressure"]),0,ONE_ATMOSPHERE*50)
|
||||
input_pressure_min = CLAMP(text2num(signal.data["set_input_pressure"]),0,ONE_ATMOSPHERE*50)
|
||||
|
||||
if("set_output_pressure" in signal.data)
|
||||
output_pressure_max = Clamp(text2num(signal.data["set_output_pressure"]),0,ONE_ATMOSPHERE*50)
|
||||
output_pressure_max = CLAMP(text2num(signal.data["set_output_pressure"]),0,ONE_ATMOSPHERE*50)
|
||||
|
||||
if("set_external_pressure" in signal.data)
|
||||
external_pressure_bound = Clamp(text2num(signal.data["set_external_pressure"]),0,ONE_ATMOSPHERE*50)
|
||||
external_pressure_bound = CLAMP(text2num(signal.data["set_external_pressure"]),0,ONE_ATMOSPHERE*50)
|
||||
|
||||
if("status" in signal.data)
|
||||
spawn(2)
|
||||
|
||||
@@ -127,7 +127,7 @@ Passive gate is similar to the regular pump except:
|
||||
pressure = text2num(pressure)
|
||||
. = TRUE
|
||||
if(.)
|
||||
target_pressure = Clamp(pressure, 0, MAX_OUTPUT_PRESSURE)
|
||||
target_pressure = CLAMP(pressure, 0, MAX_OUTPUT_PRESSURE)
|
||||
investigate_log("was set to [target_pressure] kPa by [key_name(usr)]", INVESTIGATE_ATMOS)
|
||||
update_icon()
|
||||
|
||||
@@ -149,7 +149,7 @@ Passive gate is similar to the regular pump except:
|
||||
on = !on
|
||||
|
||||
if("set_output_pressure" in signal.data)
|
||||
target_pressure = Clamp(text2num(signal.data["set_output_pressure"]),0,ONE_ATMOSPHERE*50)
|
||||
target_pressure = CLAMP(text2num(signal.data["set_output_pressure"]),0,ONE_ATMOSPHERE*50)
|
||||
|
||||
if(on != old_on)
|
||||
investigate_log("was turned [on ? "on" : "off"] by a remote signal", INVESTIGATE_ATMOS)
|
||||
|
||||
@@ -133,9 +133,14 @@ Thus, the two variables affect pump operation are set in New():
|
||||
pressure = text2num(pressure)
|
||||
. = TRUE
|
||||
if(.)
|
||||
<<<<<<< HEAD
|
||||
target_pressure = Clamp(pressure, 0, MAX_OUTPUT_PRESSURE)
|
||||
investigate_log("Pump, [src.name], was set to [target_pressure] kPa by [key_name(usr)] at [x], [y], [z], [A]", INVESTIGATE_ATMOS)
|
||||
message_admins("Pump, [src.name], was set to [target_pressure] kPa by [ADMIN_LOOKUPFLW(usr)] at [ADMIN_COORDJMP(T)], [A]")
|
||||
=======
|
||||
target_pressure = CLAMP(pressure, 0, MAX_OUTPUT_PRESSURE)
|
||||
investigate_log("was set to [target_pressure] kPa by [key_name(usr)]", INVESTIGATE_ATMOS)
|
||||
>>>>>>> 25080ff... defines math (#33498)
|
||||
update_icon()
|
||||
|
||||
/obj/machinery/atmospherics/components/binary/pump/atmosinit()
|
||||
@@ -156,7 +161,7 @@ Thus, the two variables affect pump operation are set in New():
|
||||
on = !on
|
||||
|
||||
if("set_output_pressure" in signal.data)
|
||||
target_pressure = Clamp(text2num(signal.data["set_output_pressure"]),0,ONE_ATMOSPHERE*50)
|
||||
target_pressure = CLAMP(text2num(signal.data["set_output_pressure"]),0,ONE_ATMOSPHERE*50)
|
||||
|
||||
if(on != old_on)
|
||||
investigate_log("was turned [on ? "on" : "off"] by a remote signal", INVESTIGATE_ATMOS)
|
||||
|
||||
@@ -133,9 +133,14 @@ Thus, the two variables affect pump operation are set in New():
|
||||
rate = text2num(rate)
|
||||
. = TRUE
|
||||
if(.)
|
||||
<<<<<<< HEAD
|
||||
transfer_rate = Clamp(rate, 0, MAX_TRANSFER_RATE)
|
||||
investigate_log("Volume Pump, [src.name], was set to [transfer_rate] L/s by [key_name(usr)] at [x], [y], [z], [A]", INVESTIGATE_ATMOS)
|
||||
message_admins("Volume Pump, [src.name], was set to [transfer_rate] L/s by [ADMIN_LOOKUPFLW(usr)] at [ADMIN_COORDJMP(T)], [A]")
|
||||
=======
|
||||
transfer_rate = CLAMP(rate, 0, MAX_TRANSFER_RATE)
|
||||
investigate_log("was set to [transfer_rate] L/s by [key_name(usr)]", INVESTIGATE_ATMOS)
|
||||
>>>>>>> 25080ff... defines math (#33498)
|
||||
update_icon()
|
||||
|
||||
/obj/machinery/atmospherics/components/binary/volume_pump/receive_signal(datum/signal/signal)
|
||||
@@ -152,7 +157,7 @@ Thus, the two variables affect pump operation are set in New():
|
||||
|
||||
if("set_transfer_rate" in signal.data)
|
||||
var/datum/gas_mixture/air1 = AIR1
|
||||
transfer_rate = Clamp(text2num(signal.data["set_transfer_rate"]),0,air1.volume)
|
||||
transfer_rate = CLAMP(text2num(signal.data["set_transfer_rate"]),0,air1.volume)
|
||||
|
||||
if(on != old_on)
|
||||
investigate_log("was turned [on ? "on" : "off"] by a remote signal", INVESTIGATE_ATMOS)
|
||||
|
||||
Reference in New Issue