[MIRROR] Fix nightshift skipping certain maint APCs (#5811)
* Merge pull request #36082 from AutomaticFrenzy/patch/nightshift-fix Fix nightshift skipping certain maint APCs * Fix nightshift skipping certain maint APCs
This commit is contained in:
committed by
Poojawa
parent
1a4d8b94a1
commit
fef85c1eb3
@@ -8,7 +8,6 @@ SUBSYSTEM_DEF(nightshift)
|
||||
var/nightshift_end_time = 270000 //7:30 AM, station time
|
||||
var/nightshift_first_check = 30 SECONDS
|
||||
|
||||
var/obey_security_level = TRUE
|
||||
var/high_security_mode = FALSE
|
||||
|
||||
/datum/controller/subsystem/nightshift/Initialize()
|
||||
@@ -21,48 +20,38 @@ SUBSYSTEM_DEF(nightshift)
|
||||
return
|
||||
check_nightshift()
|
||||
|
||||
/datum/controller/subsystem/nightshift/proc/announce(message)
|
||||
priority_announce(message, sound='sound/misc/notice2.ogg', sender_override="Automated Lighting System Announcement")
|
||||
|
||||
/datum/controller/subsystem/nightshift/proc/check_nightshift(force_set = FALSE)
|
||||
var/time = station_time()
|
||||
var/nightshift = time < nightshift_end_time || time > nightshift_start_time
|
||||
var/red_or_delta = GLOB.security_level == SEC_LEVEL_RED || GLOB.security_level == SEC_LEVEL_DELTA
|
||||
var/emergency = GLOB.security_level >= SEC_LEVEL_RED
|
||||
var/nightshift = FALSE
|
||||
if (!emergency)
|
||||
var/time = station_time()
|
||||
nightshift = time < nightshift_end_time || time > nightshift_start_time
|
||||
|
||||
var/announcing = TRUE
|
||||
if(nightshift && red_or_delta)
|
||||
nightshift = FALSE
|
||||
if(high_security_mode && !red_or_delta)
|
||||
if(high_security_mode && !emergency)
|
||||
high_security_mode = FALSE
|
||||
priority_announce("Restoring night lighting configuration to normal operation.", sound='sound/misc/notice2.ogg', sender_override="Automated Lighting System Announcement")
|
||||
announce("Restoring night lighting configuration to normal operation.")
|
||||
announcing = FALSE
|
||||
else if(!high_security_mode && red_or_delta)
|
||||
else if(!high_security_mode && emergency)
|
||||
high_security_mode = TRUE
|
||||
priority_announce("Night lighting disabled: Station is in a state of emergency.", sound='sound/misc/notice2.ogg', sender_override="Automated Lighting System Announcement")
|
||||
announce("Night lighting disabled: Station is in a state of emergency.")
|
||||
announcing = FALSE
|
||||
|
||||
if((nightshift_active != nightshift) || force_set)
|
||||
nightshift? activate_nightshift(announcing) : deactivate_nightshift(announcing)
|
||||
update_nightshift(nightshift, announcing)
|
||||
|
||||
/datum/controller/subsystem/nightshift/proc/activate_nightshift(announce = TRUE)
|
||||
if(!nightshift_active)
|
||||
if(announce)
|
||||
priority_announce("Good evening, crew. To reduce power consumption and stimulate the circadian rhythms of some species, all of the lights aboard the station have been dimmed for the night.", sound='sound/misc/notice2.ogg', sender_override="Automated Lighting System Announcement")
|
||||
nightshift_active = TRUE
|
||||
var/list/area/affected = return_nightshift_area_types()
|
||||
for(var/i in affected)
|
||||
var/area/A = locate(i) in GLOB.sortedAreas
|
||||
for(var/obj/machinery/power/apc/APC in A)
|
||||
APC.set_nightshift(TRUE)
|
||||
/datum/controller/subsystem/nightshift/proc/update_nightshift(active, announce = TRUE)
|
||||
nightshift_active = active
|
||||
if(announce)
|
||||
if (active)
|
||||
announce("Good evening, crew. To reduce power consumption and stimulate the circadian rhythms of some species, all of the lights aboard the station have been dimmed for the night.")
|
||||
else
|
||||
announce("Good morning, crew. As it is now day time, all of the lights aboard the station have been restored to their former brightness.")
|
||||
for(var/A in GLOB.apcs_list)
|
||||
var/obj/machinery/power/apc/APC = A
|
||||
if (APC.area && (APC.area.type in GLOB.the_station_areas))
|
||||
APC.set_nightshift(active)
|
||||
CHECK_TICK
|
||||
|
||||
/datum/controller/subsystem/nightshift/proc/deactivate_nightshift(announce = TRUE)
|
||||
if(nightshift_active)
|
||||
if(announce)
|
||||
priority_announce("Good morning, crew. As it is now day time, all of the lights aboard the station have been restored to their former brightness.", sound='sound/misc/notice2.ogg', sender_override="Automated Lighting System Announcement")
|
||||
nightshift_active = FALSE
|
||||
var/list/area/affected = return_nightshift_area_types()
|
||||
for(var/i in affected)
|
||||
var/area/A = locate(i) in GLOB.sortedAreas
|
||||
for(var/obj/machinery/power/apc/APC in A)
|
||||
APC.set_nightshift(FALSE)
|
||||
CHECK_TICK
|
||||
|
||||
/datum/controller/subsystem/nightshift/proc/return_nightshift_area_types()
|
||||
return GLOB.the_station_areas.Copy()
|
||||
|
||||
Reference in New Issue