Fixes
This commit is contained in:
@@ -91,6 +91,8 @@ GLOBAL_LIST_EMPTY(atmos_air_controllers)
|
||||
icon_screen = "tank"
|
||||
icon_keyboard = "atmos_key"
|
||||
circuit = /obj/item/circuitboard/computer/atmos_control
|
||||
ui_x = 400
|
||||
ui_y = 925
|
||||
|
||||
var/frequency = FREQ_ATMOS_STORAGE
|
||||
var/list/sensors = list(
|
||||
@@ -125,7 +127,7 @@ GLOBAL_LIST_EMPTY(atmos_air_controllers)
|
||||
datum/tgui/master_ui = null, datum/ui_state/state = GLOB.default_state)
|
||||
ui = SStgui.try_update_ui(user, src, ui_key, ui, force_open)
|
||||
if(!ui)
|
||||
ui = new(user, src, ui_key, "atmos_control", name, 400, 925, master_ui, state)
|
||||
ui = new(user, src, ui_key, "atmos_control", name, ui_x, ui_y, master_ui, state)
|
||||
ui.open()
|
||||
|
||||
/obj/machinery/computer/atmos_control/ui_data(mob/user)
|
||||
@@ -161,6 +163,20 @@ GLOBAL_LIST_EMPTY(atmos_air_controllers)
|
||||
frequency = new_frequency
|
||||
radio_connection = SSradio.add_object(src, frequency, RADIO_ATMOSIA)
|
||||
|
||||
//Incinerator sensor only
|
||||
/obj/machinery/computer/atmos_control/incinerator
|
||||
name = "Incinerator Air Control"
|
||||
sensors = list(ATMOS_GAS_MONITOR_SENSOR_INCINERATOR = "Incinerator Chamber")
|
||||
ui_x = 400
|
||||
ui_y = 300
|
||||
|
||||
//Toxins mix sensor only
|
||||
/obj/machinery/computer/atmos_control/toxinsmix
|
||||
name = "Toxins Mixing Air Control"
|
||||
sensors = list(ATMOS_GAS_MONITOR_SENSOR_TOXINS_LAB = "Toxins Mixing Chamber")
|
||||
ui_x = 400
|
||||
ui_y = 300
|
||||
|
||||
/////////////////////////////////////////////////////////////
|
||||
// LARGE TANK CONTROL
|
||||
/////////////////////////////////////////////////////////////
|
||||
@@ -174,6 +190,9 @@ GLOBAL_LIST_EMPTY(atmos_air_controllers)
|
||||
var/list/input_info
|
||||
var/list/output_info
|
||||
|
||||
ui_x = 500
|
||||
ui_y = 315
|
||||
|
||||
/obj/machinery/computer/atmos_control/tank/oxygen_tank
|
||||
name = "Oxygen Supply Control"
|
||||
input_tag = ATMOS_GAS_MONITOR_INPUT_O2
|
||||
@@ -216,12 +235,6 @@ GLOBAL_LIST_EMPTY(atmos_air_controllers)
|
||||
output_tag = ATMOS_GAS_MONITOR_OUTPUT_CO2
|
||||
sensors = list(ATMOS_GAS_MONITOR_SENSOR_CO2 = "Carbon Dioxide Tank")
|
||||
|
||||
/obj/machinery/computer/atmos_control/tank/incinerator
|
||||
name = "Incinerator Air Control"
|
||||
input_tag = ATMOS_GAS_MONITOR_INPUT_INCINERATOR
|
||||
output_tag = ATMOS_GAS_MONITOR_OUTPUT_INCINERATOR
|
||||
sensors = list(ATMOS_GAS_MONITOR_SENSOR_INCINERATOR = "Incinerator Chamber")
|
||||
|
||||
// This hacky madness is the evidence of the fact that a lot of machines were never meant to be constructable, im so sorry you had to see this
|
||||
/obj/machinery/computer/atmos_control/tank/proc/reconnect(mob/user)
|
||||
var/list/IO = list()
|
||||
@@ -235,7 +248,7 @@ GLOBAL_LIST_EMPTY(atmos_air_controllers)
|
||||
IO |= text[1]
|
||||
if(!IO.len)
|
||||
to_chat(user, "<span class='alert'>No machinery detected.</span>")
|
||||
var/S = input("Select the device set: ", "Selection", IO[1]) as anything in IO
|
||||
var/S = input("Select the device set: ", "Selection", IO[1]) as anything in sortList(IO)
|
||||
if(src)
|
||||
src.input_tag = "[S]_in"
|
||||
src.output_tag = "[S]_out"
|
||||
@@ -256,7 +269,7 @@ GLOBAL_LIST_EMPTY(atmos_air_controllers)
|
||||
datum/tgui/master_ui = null, datum/ui_state/state = GLOB.default_state)
|
||||
ui = SStgui.try_update_ui(user, src, ui_key, ui, force_open)
|
||||
if(!ui)
|
||||
ui = new(user, src, ui_key, "atmos_control", name, 500, 305, master_ui, state)
|
||||
ui = new(user, src, ui_key, "atmos_control", name, ui_x, ui_y, master_ui, state)
|
||||
ui.open()
|
||||
|
||||
/obj/machinery/computer/atmos_control/tank/ui_data(mob/user)
|
||||
@@ -280,13 +293,19 @@ GLOBAL_LIST_EMPTY(atmos_air_controllers)
|
||||
if("input")
|
||||
signal.data += list("tag" = input_tag, "power_toggle" = TRUE)
|
||||
. = TRUE
|
||||
if("rate")
|
||||
var/target = text2num(params["rate"])
|
||||
if(!isnull(target))
|
||||
target = CLAMP(target, 0, MAX_TRANSFER_RATE)
|
||||
signal.data += list("tag" = input_tag, "set_volume_rate" = target)
|
||||
. = TRUE
|
||||
if("output")
|
||||
signal.data += list("tag" = output_tag, "power_toggle" = TRUE)
|
||||
. = TRUE
|
||||
if("pressure")
|
||||
var/target = input("New target pressure:", name, output_info ? output_info["internal"] : 0) as num|null
|
||||
if(!isnull(target) && !..())
|
||||
target = CLAMP(target, 0, 50 * ONE_ATMOSPHERE)
|
||||
var/target = text2num(params["pressure"])
|
||||
if(!isnull(target))
|
||||
target = CLAMP(target, 0, 4500)
|
||||
signal.data += list("tag" = output_tag, "set_internal_pressure" = target)
|
||||
. = TRUE
|
||||
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
|
||||
|
||||
Reference in New Issue