Files
GS13NG/code/modules/atmospherics/machinery/components/binary_devices/pump.dm
deathride58 2f9e3e403d Hard upstream sync (#6951)
* maps - none of our changes included yet i'll get them in after i finish up the rest of the sync

* sync part 1 - underscore folders in code

* controllers folder

* datums folder

* game folder

* cmon, work

* modules - admin to awaymissions

* cargo to events

* fields to lighting

* mapping > ruins

* rest of the code folder

* rest of the folders in the root directory

* DME

* fixes compiling errors. it compiles so it works

* readds map changes

* fixes dogborg module select

* fixes typo in moduleselect_alternate_icon filepath
2018-05-31 16:03:18 -07:00

199 lines
6.1 KiB
Plaintext

/*
Every cycle, the pump uses the air in air_in to try and make air_out the perfect pressure.
node1, air1, network1 correspond to input
node2, air2, network2 correspond to output
Thus, the two variables affect pump operation are set in New():
air1.volume
This is the volume of gas available to the pump that may be transfered to the output
air2.volume
Higher quantities of this cause more air to be perfected later
but overall network volume is also increased as this increases...
*/
/obj/machinery/atmospherics/components/binary/pump
icon_state = "pump_map"
name = "gas pump"
desc = "A pump that moves gas by pressure."
can_unwrench = TRUE
var/target_pressure = ONE_ATMOSPHERE
var/frequency = 0
var/id = null
var/datum/radio_frequency/radio_connection
construction_type = /obj/item/pipe/directional
pipe_state = "pump"
/obj/machinery/atmospherics/components/binary/pump/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/binary/pump/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/binary/pump/on
on = TRUE
icon_state = "pump_on_map"
/obj/machinery/atmospherics/components/binary/pump/on/layer1
piping_layer = PIPING_LAYER_MIN
pixel_x = -PIPING_LAYER_P_X
pixel_y = -PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/binary/pump/on/layer3
piping_layer = PIPING_LAYER_MAX
pixel_x = PIPING_LAYER_P_X
pixel_y = PIPING_LAYER_P_Y
/obj/machinery/atmospherics/components/binary/pump/Destroy()
SSradio.remove_object(src,frequency)
if(radio_connection)
radio_connection = null
return ..()
/obj/machinery/atmospherics/components/binary/pump/update_icon_nopipes()
if(!is_operational())
icon_state = "pump_off"
return
icon_state = "pump_[on?"on":"off"]"
/obj/machinery/atmospherics/components/binary/pump/process_atmos()
// ..()
if(!on || !is_operational())
return
var/datum/gas_mixture/air1 = airs[1]
var/datum/gas_mixture/air2 = airs[2]
var/output_starting_pressure = air2.return_pressure()
if((target_pressure - output_starting_pressure) < 0.01)
//No need to pump gas if target is already reached!
return
//Calculate necessary moles to transfer using PV=nRT
if((air1.total_moles() > 0) && (air1.temperature>0))
var/pressure_delta = target_pressure - output_starting_pressure
var/transfer_moles = pressure_delta*air2.volume/(air1.temperature * R_IDEAL_GAS_EQUATION)
//Actually transfer the gas
var/datum/gas_mixture/removed = air1.remove(transfer_moles)
air2.merge(removed)
update_parents()
//Radio remote control
/obj/machinery/atmospherics/components/binary/pump/proc/set_frequency(new_frequency)
SSradio.remove_object(src, frequency)
frequency = new_frequency
if(frequency)
radio_connection = SSradio.add_object(src, frequency, filter = RADIO_ATMOSIA)
/obj/machinery/atmospherics/components/binary/pump/proc/broadcast_status()
if(!radio_connection)
return
var/datum/signal/signal = new(list(
"tag" = id,
"device" = "AGP",
"power" = on,
"target_output" = target_pressure,
"sigtype" = "status"
))
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
/obj/machinery/atmospherics/components/binary/pump/ui_interact(mob/user, ui_key = "main", datum/tgui/ui = null, force_open = FALSE, \
datum/tgui/master_ui = null, datum/ui_state/state = GLOB.default_state)
ui = SStgui.try_update_ui(user, src, ui_key, ui, force_open)
if(!ui)
ui = new(user, src, ui_key, "atmos_pump", name, 335, 115, master_ui, state)
ui.open()
/obj/machinery/atmospherics/components/binary/pump/ui_data()
var/data = list()
data["on"] = on
data["pressure"] = round(target_pressure)
data["max_pressure"] = round(MAX_OUTPUT_PRESSURE)
return data
/obj/machinery/atmospherics/components/binary/pump/ui_act(action, params)
if(..())
return
var/turf/T = get_turf(src)
var/area/A = get_area(src)
switch(action)
if("power")
on = !on
investigate_log("Pump, [src.name], was turned [on ? "on" : "off"] by [key_name(usr)] at [x], [y], [z], [A]", INVESTIGATE_ATMOS)
message_admins("Pump, [src.name], turned [on ? "on" : "off"] by [ADMIN_LOOKUPFLW(usr)] at [ADMIN_COORDJMP(T)], [A]")
. = TRUE
if("pressure")
var/pressure = params["pressure"]
if(pressure == "max")
pressure = MAX_OUTPUT_PRESSURE
. = TRUE
else if(pressure == "input")
pressure = input("New output pressure (0-[MAX_OUTPUT_PRESSURE] kPa):", name, target_pressure) as num|null
if(!isnull(pressure) && !..())
. = TRUE
else if(text2num(pressure) != null)
pressure = text2num(pressure)
. = TRUE
if(.)
target_pressure = CLAMP(pressure, 0, MAX_OUTPUT_PRESSURE)
investigate_log("was set to [target_pressure] kPa by [key_name(usr)]", INVESTIGATE_ATMOS)
update_icon()
/obj/machinery/atmospherics/components/binary/pump/atmosinit()
..()
if(frequency)
set_frequency(frequency)
/obj/machinery/atmospherics/components/binary/pump/receive_signal(datum/signal/signal)
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
return
var/old_on = on //for logging
if("power" in signal.data)
on = text2num(signal.data["power"])
if("power_toggle" in signal.data)
on = !on
if("set_output_pressure" in signal.data)
target_pressure = CLAMP(text2num(signal.data["set_output_pressure"]),0,ONE_ATMOSPHERE*50)
if(on != old_on)
investigate_log("was turned [on ? "on" : "off"] by a remote signal", INVESTIGATE_ATMOS)
if("status" in signal.data)
broadcast_status()
return
broadcast_status()
update_icon()
/obj/machinery/atmospherics/components/binary/pump/power_change()
..()
update_icon()
/obj/machinery/atmospherics/components/binary/pump/can_unwrench(mob/user)
. = ..()
var/area/A = get_area(src)
if(. && on && is_operational())
to_chat(user, "<span class='warning'>You cannot unwrench [src], turn it off first!</span>")
return FALSE
else
investigate_log("Pump, [src.name], was unwrenched by [key_name(usr)] at [x], [y], [z], [A]", INVESTIGATE_ATMOS)
message_admins("Pump, [src.name], was unwrenched by [ADMIN_LOOKUPFLW(user)] at [A]")
return TRUE