// Every cycle, the pump uses the air in air_in to try and make air_out the perfect pressure.
//
// node1, air1, network1 correspond to input
// node2, air2, network2 correspond to output
//
// Thus, the two variables affect pump operation are set in New():
// air1.volume
// This is the volume of gas available to the pump that may be transfered to the output
// air2.volume
// Higher quantities of this cause more air to be perfected later
// but overall network volume is also increased as this increases...
/obj/machinery/atmospherics/components/binary/volume_pump
icon_state = "volpump_map-2"
name = "volumetric gas pump"
desc = "A pump that moves gas by volume."
can_unwrench = TRUE
shift_underlay_only = FALSE
var/transfer_rate = MAX_TRANSFER_RATE
var/frequency = 0
var/id = null
var/datum/radio_frequency/radio_connection
construction_type = /obj/item/pipe/directional
pipe_state = "volumepump"
/obj/machinery/atmospherics/components/binary/volume_pump/examine(mob/user)
. = ..()
. += "<span class='notice'>You can hold <b>Ctrl</b> and click on it to toggle it on and off.</span>"
. += "<span class='notice'>You can hold <b>Alt</b> and click on it to maximize its pressure.</span>"
/obj/machinery/atmospherics/components/binary/volume_pump/CtrlClick(mob/user)
var/area/A = get_area(src)
var/turf/T = get_turf(src)
if(user.canUseTopic(src, BE_CLOSE, FALSE,))
on = !on
update_icon()
investigate_log("Volume Pump, [src.name], turned on by [key_name(usr)] at [x], [y], [z], [A]", INVESTIGATE_ATMOS)
message_admins("Volume Pump, [src.name], turned [on ? "on" : "off"] by [ADMIN_LOOKUPFLW(usr)] at [ADMIN_COORDJMP(T)], [A]")
return ..()
/obj/machinery/atmospherics/components/binary/volume_pump/Destroy()
SSradio.remove_object(src,frequency)
return ..()
/obj/machinery/atmospherics/components/binary/volume_pump/update_icon_nopipes()
icon_state = on && is_operational() ? "volpump_on" : "volpump_off"
/obj/machinery/atmospherics/components/binary/volume_pump/process_atmos()
// ..()
if(!on || !is_operational())
return
var/datum/gas_mixture/air1 = airs[1]
var/datum/gas_mixture/air2 = airs[2]
// Pump mechanism just won't do anything if the pressure is too high/too low
var/input_starting_pressure = air1.return_pressure()
var/output_starting_pressure = air2.return_pressure()
if((input_starting_pressure < 0.01) || (output_starting_pressure > 9000))
return
var/transfer_ratio = transfer_rate/air1.return_volume()
var/datum/gas_mixture/removed = air1.remove_ratio(transfer_ratio)
air2.merge(removed)
update_parents()
/obj/machinery/atmospherics/components/binary/volume_pump/proc/set_frequency(new_frequency)
SSradio.remove_object(src, frequency)
frequency = new_frequency
if(frequency)
radio_connection = SSradio.add_object(src, frequency)
/obj/machinery/atmospherics/components/binary/volume_pump/proc/broadcast_status()
if(!radio_connection)
return
var/datum/signal/signal = new(list(
"tag" = id,
"device" = "APV",
"power" = on,
"transfer_rate" = transfer_rate,
"sigtype" = "status"
))
radio_connection.post_signal(src, signal)
/obj/machinery/atmospherics/components/binary/volume_pump/ui_interact(mob/user, datum/tgui/ui)
ui = SStgui.try_update_ui(user, src, ui)
if(!ui)
ui = new(user, src, "AtmosPump", name)
ui.open()
/obj/machinery/atmospherics/components/binary/volume_pump/ui_data()
var/data = list()
data["on"] = on
data["rate"] = round(transfer_rate)
data["max_rate"] = round(MAX_TRANSFER_RATE)
return data
/obj/machinery/atmospherics/components/binary/volume_pump/atmosinit()
..()
set_frequency(frequency)
/obj/machinery/atmospherics/components/binary/volume_pump/ui_act(action, params)
if(..())
return
var/turf/T = get_turf(src)
var/area/A = get_area(src)
switch(action)
if("power")
on = !on
message_admins("Pump, [src.name], turned [on ? "on" : "off"] by [ADMIN_LOOKUPFLW(usr)] at [ADMIN_COORDJMP(T)], [A]")
investigate_log("was turned [on ? "on" : "off"] by [key_name(usr)]", INVESTIGATE_ATMOS)
. = TRUE
if("rate")
var/rate = params["rate"]
if(rate == "max")
rate = MAX_TRANSFER_RATE
. = TRUE
else if(rate == "input")
rate = input("New transfer rate (0-[MAX_TRANSFER_RATE] L/s):", name, transfer_rate) as num|null
if(!isnull(rate) && !..())
. = TRUE
else if(text2num(rate) != null)
rate = text2num(rate)
. = TRUE
if(.)
transfer_rate = clamp(rate, 0, MAX_TRANSFER_RATE)
investigate_log("was set to [transfer_rate] L/s by [key_name(usr)]", INVESTIGATE_ATMOS)
update_icon()
/obj/machinery/atmospherics/components/binary/volume_pump/receive_signal(datum/signal/signal)
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
return
var/old_on = on //for logging
if("power" in signal.data)
on = text2num(signal.data["power"])
if("power_toggle" in signal.data)
on = !on
if("set_transfer_rate" in signal.data)
var/datum/gas_mixture/air1 = airs[1]
transfer_rate = clamp(text2num(signal.data["set_transfer_rate"]),0,air1.return_volume())
if(on != old_on)
investigate_log("was turned [on ? "on" : "off"] by a remote signal", INVESTIGATE_ATMOS)
if("status" in signal.data)
broadcast_status()
return //do not update_icon
broadcast_status()
update_icon()
/obj/machinery/atmospherics/components/binary/volume_pump/power_change()
..()
update_icon()
/obj/machinery/atmospherics/components/binary/volume_pump/can_unwrench(mob/user)
. = ..()
var/area/A = get_area(src)
if(. && on && is_operational())
to_chat(user, "<span class='warning'>You cannot unwrench [src], turn it off first!</span>")
return FALSE
else
investigate_log("Pump, [src.name], was unwrenched by [key_name(usr)] at [x], [y], [z], [A]", INVESTIGATE_ATMOS)
message_admins("Pump, [src.name], was unwrenched by [ADMIN_LOOKUPFLW(user)] at [A]")
return TRUE
// Mapping
/obj/machinery/atmospherics/components/binary/volume_pump/layer1
piping_layer = 1
icon_state = "volpump_map-1"
/obj/machinery/atmospherics/components/binary/volume_pump/layer3
piping_layer = 3
icon_state = "volpump_map-3"
/obj/machinery/atmospherics/components/binary/volume_pump/on
on = TRUE
icon_state = "volpump_on_map"
/obj/machinery/atmospherics/components/binary/volume_pump/on/layer1
piping_layer = 1
icon_state = "volpump_map-1"
/obj/machinery/atmospherics/components/binary/volume_pump/on/layer3
piping_layer = 3
icon_state = "volpump_map-3"