mirror of
https://github.com/Bubberstation/Bubberstation.git
synced 2026-08-29 16:18:01 +01:00
[s] Fixes vents not logging the signal sender (#43272)
* [s] Fixes vents not logging the signal sender * removed unused proc
This commit is contained in:
@@ -44,7 +44,7 @@
|
||||
A.mode = 3 // AALARM_MODE_PANIC
|
||||
else
|
||||
A.mode = 1 // AALARM_MODE_SCRUB
|
||||
A.apply_mode()
|
||||
A.apply_mode(usr)
|
||||
if(WIRE_ALARM) // Clear alarms.
|
||||
var/area/AA = get_area(A)
|
||||
if(AA.atmosalert(0, holder))
|
||||
@@ -66,9 +66,9 @@
|
||||
if(WIRE_PANIC) // Force panic syphon on.
|
||||
if(!mend && !A.shorted)
|
||||
A.mode = 3 // AALARM_MODE_PANIC
|
||||
A.apply_mode()
|
||||
A.apply_mode(usr)
|
||||
if(WIRE_ALARM) // Post alarm.
|
||||
var/area/AA = get_area(A)
|
||||
if(AA.atmosalert(2, holder))
|
||||
A.post_alert(2)
|
||||
A.update_icon()
|
||||
A.update_icon()
|
||||
|
||||
@@ -417,7 +417,7 @@
|
||||
if("mode")
|
||||
mode = text2num(params["mode"])
|
||||
investigate_log("was turned to [get_mode_name(mode)] mode by [key_name(usr)]",INVESTIGATE_ATMOS)
|
||||
apply_mode()
|
||||
apply_mode(usr)
|
||||
. = TRUE
|
||||
if("alarm")
|
||||
var/area/A = get_area(src)
|
||||
@@ -456,25 +456,12 @@
|
||||
else
|
||||
return 0
|
||||
|
||||
/obj/machinery/airalarm/proc/refresh_all()
|
||||
var/area/A = get_area(src)
|
||||
for(var/id_tag in A.air_vent_names)
|
||||
var/list/I = A.air_vent_info[id_tag]
|
||||
if(I && I["timestamp"] + AALARM_REPORT_TIMEOUT / 2 > world.time)
|
||||
continue
|
||||
send_signal(id_tag, list("status"))
|
||||
for(var/id_tag in A.air_scrub_names)
|
||||
var/list/I = A.air_scrub_info[id_tag]
|
||||
if(I && I["timestamp"] + AALARM_REPORT_TIMEOUT / 2 > world.time)
|
||||
continue
|
||||
send_signal(id_tag, list("status"))
|
||||
|
||||
/obj/machinery/airalarm/proc/set_frequency(new_frequency)
|
||||
SSradio.remove_object(src, frequency)
|
||||
frequency = new_frequency
|
||||
radio_connection = SSradio.add_object(src, frequency, RADIO_TO_AIRALARM)
|
||||
|
||||
/obj/machinery/airalarm/proc/send_signal(target, list/command, mob/user)//sends signal 'command' to 'target'. Returns 0 if no radio connection, 1 otherwise
|
||||
/obj/machinery/airalarm/proc/send_signal(target, list/command, atom/user)//sends signal 'command' to 'target'. Returns 0 if no radio connection, 1 otherwise
|
||||
if(!radio_connection)
|
||||
return 0
|
||||
|
||||
@@ -507,7 +494,7 @@
|
||||
if(AALARM_MODE_FLOOD)
|
||||
return "Flood"
|
||||
|
||||
/obj/machinery/airalarm/proc/apply_mode()
|
||||
/obj/machinery/airalarm/proc/apply_mode(atom/signal_source)
|
||||
var/area/A = get_area(src)
|
||||
switch(mode)
|
||||
if(AALARM_MODE_SCRUBBING)
|
||||
@@ -516,14 +503,14 @@
|
||||
"power" = 1,
|
||||
"set_filters" = list(/datum/gas/carbon_dioxide),
|
||||
"scrubbing" = 1,
|
||||
"widenet" = 0,
|
||||
))
|
||||
"widenet" = 0
|
||||
), signal_source)
|
||||
for(var/device_id in A.air_vent_names)
|
||||
send_signal(device_id, list(
|
||||
"power" = 1,
|
||||
"checks" = 1,
|
||||
"set_external_pressure" = ONE_ATMOSPHERE
|
||||
))
|
||||
), signal_source)
|
||||
if(AALARM_MODE_CONTAMINATED)
|
||||
for(var/device_id in A.air_scrub_names)
|
||||
send_signal(device_id, list(
|
||||
@@ -542,41 +529,41 @@
|
||||
/datum/gas/pluoxium
|
||||
),
|
||||
"scrubbing" = 1,
|
||||
"widenet" = 1,
|
||||
))
|
||||
"widenet" = 1
|
||||
), signal_source)
|
||||
for(var/device_id in A.air_vent_names)
|
||||
send_signal(device_id, list(
|
||||
"power" = 1,
|
||||
"checks" = 1,
|
||||
"set_external_pressure" = ONE_ATMOSPHERE
|
||||
))
|
||||
), signal_source)
|
||||
if(AALARM_MODE_VENTING)
|
||||
for(var/device_id in A.air_scrub_names)
|
||||
send_signal(device_id, list(
|
||||
"power" = 1,
|
||||
"widenet" = 0,
|
||||
"scrubbing" = 0
|
||||
))
|
||||
), signal_source)
|
||||
for(var/device_id in A.air_vent_names)
|
||||
send_signal(device_id, list(
|
||||
"power" = 1,
|
||||
"checks" = 1,
|
||||
"set_external_pressure" = ONE_ATMOSPHERE*2
|
||||
))
|
||||
), signal_source)
|
||||
if(AALARM_MODE_REFILL)
|
||||
for(var/device_id in A.air_scrub_names)
|
||||
send_signal(device_id, list(
|
||||
"power" = 1,
|
||||
"set_filters" = list(/datum/gas/carbon_dioxide),
|
||||
"scrubbing" = 1,
|
||||
"widenet" = 0,
|
||||
))
|
||||
"widenet" = 0
|
||||
), signal_source)
|
||||
for(var/device_id in A.air_vent_names)
|
||||
send_signal(device_id, list(
|
||||
"power" = 1,
|
||||
"checks" = 1,
|
||||
"set_external_pressure" = ONE_ATMOSPHERE * 3
|
||||
))
|
||||
), signal_source)
|
||||
if(AALARM_MODE_PANIC,
|
||||
AALARM_MODE_REPLACEMENT)
|
||||
for(var/device_id in A.air_scrub_names)
|
||||
@@ -584,43 +571,43 @@
|
||||
"power" = 1,
|
||||
"widenet" = 1,
|
||||
"scrubbing" = 0
|
||||
))
|
||||
), signal_source)
|
||||
for(var/device_id in A.air_vent_names)
|
||||
send_signal(device_id, list(
|
||||
"power" = 0
|
||||
))
|
||||
), signal_source)
|
||||
if(AALARM_MODE_SIPHON)
|
||||
for(var/device_id in A.air_scrub_names)
|
||||
send_signal(device_id, list(
|
||||
"power" = 1,
|
||||
"widenet" = 0,
|
||||
"scrubbing" = 0
|
||||
))
|
||||
), signal_source)
|
||||
for(var/device_id in A.air_vent_names)
|
||||
send_signal(device_id, list(
|
||||
"power" = 0
|
||||
))
|
||||
), signal_source)
|
||||
|
||||
if(AALARM_MODE_OFF)
|
||||
for(var/device_id in A.air_scrub_names)
|
||||
send_signal(device_id, list(
|
||||
"power" = 0
|
||||
))
|
||||
), signal_source)
|
||||
for(var/device_id in A.air_vent_names)
|
||||
send_signal(device_id, list(
|
||||
"power" = 0
|
||||
))
|
||||
), signal_source)
|
||||
if(AALARM_MODE_FLOOD)
|
||||
for(var/device_id in A.air_scrub_names)
|
||||
send_signal(device_id, list(
|
||||
"power" = 0
|
||||
))
|
||||
), signal_source)
|
||||
for(var/device_id in A.air_vent_names)
|
||||
send_signal(device_id, list(
|
||||
"power" = 1,
|
||||
"checks" = 2,
|
||||
"set_internal_pressure" = 0
|
||||
))
|
||||
), signal_source)
|
||||
|
||||
/obj/machinery/airalarm/update_icon()
|
||||
if(panel_open)
|
||||
@@ -683,7 +670,7 @@
|
||||
apply_danger_level()
|
||||
if(mode == AALARM_MODE_REPLACEMENT && environment_pressure < ONE_ATMOSPHERE * 0.05)
|
||||
mode = AALARM_MODE_SCRUBBING
|
||||
apply_mode()
|
||||
apply_mode(src)
|
||||
|
||||
|
||||
/obj/machinery/airalarm/proc/post_alert(alert_level)
|
||||
|
||||
@@ -182,7 +182,7 @@
|
||||
if(!signal.data["tag"] || (signal.data["tag"] != id_tag) || (signal.data["sigtype"]!="command"))
|
||||
return
|
||||
|
||||
var/mob/signal_sender = signal.data["user"]
|
||||
var/atom/signal_sender = signal.data["user"]
|
||||
|
||||
if("purge" in signal.data)
|
||||
pressure_checks &= ~EXT_BOUND
|
||||
|
||||
@@ -218,7 +218,7 @@
|
||||
if(!is_operational() || !signal.data["tag"] || (signal.data["tag"] != id_tag) || (signal.data["sigtype"]!="command"))
|
||||
return 0
|
||||
|
||||
var/mob/signal_sender = signal.data["user"]
|
||||
var/atom/signal_sender = signal.data["user"]
|
||||
|
||||
if("power" in signal.data)
|
||||
on = text2num(signal.data["power"])
|
||||
|
||||
Reference in New Issue