mirror of
https://github.com/Bubberstation/Bubberstation.git
synced 2026-08-28 23:58:07 +01:00
tgui power monitor; linegraph component
This commit is contained in:
@@ -1,113 +0,0 @@
|
||||
// the power monitoring computer
|
||||
// for the moment, just report the status of all APCs in the same powernet
|
||||
/obj/machinery/computer/monitor
|
||||
name = "power monitoring console"
|
||||
desc = "It monitors power levels across the station."
|
||||
icon_screen = "power"
|
||||
icon_keyboard = "power_key"
|
||||
use_power = 2
|
||||
idle_power_usage = 20
|
||||
active_power_usage = 80
|
||||
circuit = /obj/item/weapon/circuitboard/powermonitor
|
||||
var/datum/powernet/powernet = null
|
||||
|
||||
//fix for issue 521, by QualityVan.
|
||||
//someone should really look into why circuits have a powernet var, it's several kinds of retarded.
|
||||
/obj/machinery/computer/monitor/New()
|
||||
..()
|
||||
var/obj/structure/cable/attached = null
|
||||
var/turf/T = loc
|
||||
if(isturf(T))
|
||||
attached = locate() in T
|
||||
if(attached)
|
||||
powernet = attached.get_powernet()
|
||||
|
||||
/obj/machinery/computer/monitor/process() //oh shit, somehow we didnt end up with a powernet... lets look for one.
|
||||
if(!powernet)
|
||||
var/obj/structure/cable/attached = null
|
||||
var/turf/T = loc
|
||||
if(isturf(T))
|
||||
attached = locate() in T
|
||||
if(attached)
|
||||
powernet = attached.get_powernet()
|
||||
return
|
||||
|
||||
/obj/machinery/computer/monitor/attack_hand(mob/user)
|
||||
if(..())
|
||||
return
|
||||
interact(user)
|
||||
|
||||
/obj/machinery/computer/monitor/interact(mob/user)
|
||||
if ( (get_dist(src, user) > 1 ) || (stat & (BROKEN|NOPOWER)) )
|
||||
if (!(istype(user, /mob/living/silicon) || IsAdminGhost(user)))
|
||||
user.unset_machine()
|
||||
user << browse(null, "window=powcomp")
|
||||
return
|
||||
|
||||
|
||||
user.set_machine(src)
|
||||
var/t = ""
|
||||
|
||||
t += "<A href='?src=\ref[src];update=1'>Refresh</A> <A href='?src=\ref[src];close=1'>Close</A><br /><br />"
|
||||
|
||||
if(!powernet)
|
||||
t += "<span class='danger'>No connection.</span>"
|
||||
else
|
||||
|
||||
var/list/L = list()
|
||||
for(var/obj/machinery/power/terminal/term in powernet.nodes)
|
||||
if(istype(term.master, /obj/machinery/power/apc))
|
||||
var/obj/machinery/power/apc/A = term.master
|
||||
L += A
|
||||
|
||||
t += "<PRE>Total power: [powernet.avail] W<BR>Total load: [num2text(powernet.viewload,10)] W<BR>"
|
||||
|
||||
t += "<FONT SIZE=-1>"
|
||||
|
||||
if(L.len > 0)
|
||||
|
||||
t += "Area Eqp./Lgt./Env. Load Cell<HR>"
|
||||
|
||||
var/list/S = list("<SPAN class='bad'> Off</SPAN>","<SPAN class='bad'>AOff</SPAN>","<SPAN class='good'> On</SPAN>", "<SPAN class='good'> AOn</SPAN>")
|
||||
var/list/chg = list("<SPAN class='bad'>N</SPAN>","<SPAN class='average'>C</SPAN>","<SPAN class='good'>F</SPAN>")
|
||||
|
||||
var/percent = 0
|
||||
var/c = ""
|
||||
|
||||
for(var/obj/machinery/power/apc/A in L)
|
||||
|
||||
t += copytext(add_tspace("[format_text(A.area.name)]", 30), 1, 30)
|
||||
t += " [S[A.equipment+1]] [S[A.lighting+1]] [S[A.environ+1]] [add_lspace(A.lastused_total, 6)]"
|
||||
|
||||
if (A.cell)
|
||||
percent = round(A.cell.percent())
|
||||
|
||||
c = "bad"
|
||||
if (percent > 50)
|
||||
c = "good"
|
||||
else if (percent > 25)
|
||||
c = "average"
|
||||
|
||||
t += "<SPAN class='[c]'>[add_lspace(percent, 4)]%</SPAN> [chg[A.charging+1]]<BR>"
|
||||
else
|
||||
t += " N/C<BR>"
|
||||
|
||||
t += "</FONT></PRE>"
|
||||
|
||||
//user << browse(t, "window=powcomp;size=420x900")
|
||||
//onclose(user, "powcomp")
|
||||
var/datum/browser/popup = new(user, "powcomp", name, 500, 450)
|
||||
popup.set_content(t)
|
||||
popup.set_title_image(user.browse_rsc_icon(src.icon, src.icon_state))
|
||||
popup.open()
|
||||
|
||||
/obj/machinery/computer/monitor/Topic(href, href_list)
|
||||
if(..())
|
||||
return
|
||||
if( href_list["close"] )
|
||||
usr << browse(null, "window=powcomp")
|
||||
usr.unset_machine()
|
||||
return
|
||||
if( href_list["update"] )
|
||||
src.updateDialog()
|
||||
return
|
||||
@@ -347,12 +347,12 @@ Code:
|
||||
menu += "<span class='danger'>No connection<BR></span>"
|
||||
else
|
||||
var/list/L = list()
|
||||
for(var/obj/machinery/power/terminal/term in powmonitor.powernet.nodes)
|
||||
for(var/obj/machinery/power/terminal/term in powmonitor.attached.powernet.nodes)
|
||||
if(istype(term.master, /obj/machinery/power/apc))
|
||||
var/obj/machinery/power/apc/A = term.master
|
||||
L += A
|
||||
|
||||
menu += "<PRE>Total power: [powmonitor.powernet.avail] W<BR>Total load: [num2text(powmonitor.powernet.viewload,10)] W<BR>"
|
||||
menu += "<PRE>Total power: [powmonitor.attached.powernet.viewavail] W<BR>Total load: [num2text(powmonitor.attached.powernet.viewload,10)] W<BR>"
|
||||
|
||||
menu += "<FONT SIZE=-1>"
|
||||
|
||||
|
||||
@@ -6,7 +6,6 @@
|
||||
var/icon_state_open = "cold_off"
|
||||
density = TRUE
|
||||
anchored = TRUE
|
||||
idle_power_usage = 25
|
||||
|
||||
var/on = FALSE
|
||||
var/min_temperature = 0
|
||||
|
||||
@@ -625,7 +625,7 @@
|
||||
"powerCellStatus" = cell ? cell.percent() : null,
|
||||
"chargeMode" = chargemode,
|
||||
"chargingStatus" = charging,
|
||||
"totalLoad" = lastused_equip + lastused_light + lastused_environ,
|
||||
"totalLoad" = lastused_total,
|
||||
"coverLocked" = coverlocked,
|
||||
"siliconUser" = user.has_unlimited_silicon_privilege,
|
||||
"malfStatus" = get_malf_status(user),
|
||||
|
||||
@@ -114,11 +114,6 @@ By design, d1 is the smallest direction and d2 is the highest
|
||||
else
|
||||
icon_state = "[d1]-[d2]"
|
||||
|
||||
|
||||
// returns the powernet this cable belongs to
|
||||
/obj/structure/cable/proc/get_powernet() //TODO: remove this as it is obsolete
|
||||
return powernet
|
||||
|
||||
//Telekinesis has no effect on a cable
|
||||
/obj/structure/cable/attack_tk(mob/user)
|
||||
return
|
||||
|
||||
@@ -0,0 +1,81 @@
|
||||
/obj/machinery/computer/monitor
|
||||
name = "power monitoring console"
|
||||
desc = "It monitors power levels across the station."
|
||||
icon_screen = "power"
|
||||
icon_keyboard = "power_key"
|
||||
use_power = 2
|
||||
idle_power_usage = 20
|
||||
active_power_usage = 100
|
||||
circuit = /obj/item/weapon/circuitboard/powermonitor
|
||||
|
||||
var/obj/structure/cable/attached
|
||||
|
||||
var/list/history = list()
|
||||
var/record_size = 60
|
||||
var/record_interval = 50
|
||||
var/next_record = 0
|
||||
|
||||
/obj/machinery/computer/monitor/New()
|
||||
..()
|
||||
search()
|
||||
history["supply"] = list()
|
||||
history["demand"] = list()
|
||||
|
||||
/obj/machinery/computer/monitor/process()
|
||||
if(!attached)
|
||||
use_power = 1
|
||||
search()
|
||||
else
|
||||
use_power = 2
|
||||
record()
|
||||
|
||||
/obj/machinery/computer/monitor/proc/search()
|
||||
var/turf/T = get_turf(src)
|
||||
attached = locate() in T
|
||||
|
||||
/obj/machinery/computer/monitor/proc/record()
|
||||
if(world.time >= next_record)
|
||||
next_record = world.time + record_interval
|
||||
|
||||
var/list/supply = history["supply"]
|
||||
supply += attached.powernet.viewavail
|
||||
if(supply.len > record_size)
|
||||
supply.Cut(1, 2)
|
||||
|
||||
var/list/demand = history["demand"]
|
||||
demand += attached.powernet.viewload
|
||||
if(demand.len > record_size)
|
||||
demand.Cut(1, 2)
|
||||
|
||||
/obj/machinery/computer/monitor/ui_interact(mob/user, ui_key = "main", datum/tgui/ui = null, force_open = 0, \
|
||||
datum/tgui/master_ui = null, datum/ui_state/state = default_state)
|
||||
ui = SStgui.try_update_ui(user, src, ui_key, ui, force_open)
|
||||
if(!ui)
|
||||
ui = new(user, src, ui_key, "power_monitor", name, 1200, 1000, master_ui, state)
|
||||
ui.open()
|
||||
|
||||
/obj/machinery/computer/monitor/get_ui_data()
|
||||
var/list/data = list()
|
||||
data["stored"] = record_size
|
||||
data["interval"] = record_interval / 10
|
||||
data["attached"] = attached ? TRUE : FALSE
|
||||
if(attached)
|
||||
data["supply"] = attached.powernet.viewavail
|
||||
data["demand"] = attached.powernet.viewload
|
||||
data["history"] = history
|
||||
|
||||
data["areas"] = list()
|
||||
for(var/obj/machinery/power/terminal/term in attached.powernet.nodes)
|
||||
var/obj/machinery/power/apc/A = term.master
|
||||
if(istype(A))
|
||||
data["areas"] += list(list(
|
||||
"name" = A.area.name,
|
||||
"charge" = A.cell.percent(),
|
||||
"load" = A.lastused_total,
|
||||
"charging" = A.charging,
|
||||
"eqp" = A.equipment,
|
||||
"lgt" = A.lighting,
|
||||
"env" = A.environ
|
||||
))
|
||||
|
||||
return data
|
||||
@@ -34,7 +34,7 @@
|
||||
|
||||
/obj/machinery/power/proc/surplus()
|
||||
if(powernet)
|
||||
return powernet.avail-powernet.load
|
||||
return powernet.avail - powernet.load
|
||||
else
|
||||
return 0
|
||||
|
||||
|
||||
@@ -3,14 +3,15 @@
|
||||
// each contiguous network of cables & nodes
|
||||
/////////////////////////////////////
|
||||
/datum/powernet
|
||||
var/number // unique id
|
||||
var/list/cables = list() // all cables & junctions
|
||||
var/list/nodes = list() // all connected machines
|
||||
|
||||
var/load = 0 // the current load on the powernet, increased by each machine at processing
|
||||
var/newavail = 0 // what available power was gathered last tick, then becomes...
|
||||
var/avail = 0 //...the current available power in the powernet
|
||||
var/viewavail = 0 // the available power as it appears on the power console (gradually updated)
|
||||
var/viewload = 0 // the load as it appears on the power console (gradually updated)
|
||||
var/number = 0 // Unused //TODEL
|
||||
var/netexcess = 0 // excess power on the powernet (typically avail-load)///////
|
||||
|
||||
/datum/powernet/New()
|
||||
@@ -75,7 +76,6 @@
|
||||
//handles the power changes in the powernet
|
||||
//called every ticks by the powernet controller
|
||||
/datum/powernet/proc/reset()
|
||||
|
||||
//see if there's a surplus of power remaining in the powernet and stores unused power in the SMES
|
||||
netexcess = avail - load
|
||||
|
||||
@@ -83,11 +83,11 @@
|
||||
for(var/obj/machinery/power/smes/S in nodes) // find the SMESes in the network
|
||||
S.restore() // and restore some of the power that was used
|
||||
|
||||
//updates the viewed load (as seen on power computers)
|
||||
viewload = 0.8*viewload + 0.2*load
|
||||
viewload = round(viewload)
|
||||
// update power consoles
|
||||
viewavail = round(0.8 * viewavail + 0.2 * avail)
|
||||
viewload = round(0.8 * viewload + 0.2 * load)
|
||||
|
||||
//reset the powernet
|
||||
// reset the powernet
|
||||
load = 0
|
||||
avail = newavail
|
||||
newavail = 0
|
||||
|
||||
Reference in New Issue
Block a user