mirror of
https://github.com/Bubberstation/Bubberstation.git
synced 2026-07-10 23:54:14 +01:00
Makes stations more airtight (#57535)
I've gone through delta, meta, and icebox and added some choice windoors, changed some areas around, added some more doors, and changed some other miscellaneous things. I'll list the full changes in drop downs, for both our sakes Delta: <details> Splits the central hallway into fore and aft central hallways Adds the spaces that jut out of medbay and sci into the central hallway, rather then having them be a part of medbay and sci Adds medbay access locked windoors to the back desk of the medbay reception area Adds airlocks to both the upper and lower parts of the main hallway </details> Meta: <details> Gives the storage wing another set of firelocks, and two fire alarms. It didn't have any alarms in the first place, so hopefully this helps things Adds the spaces that jut out of medbay and sci into the central hallway, rather then having them be a part of medbay and sci Replaces a small bit of the science area with nanite lab, to prevent a breach near xenobio causing fire alarms at the front of sci Adds a windoor in front of the ORM to block air Adds a wall behind a smart fridge in chemistry </details> Icebox: <details> Added airlocks between arrivals and the port hallway, and the escape hallway and the starboard hallway Added a windoor between the kitchen and the bar </details> ## Why It's Good For The Game Cuts delta's main hallway in half, with the goal of reducing fire alarm strain. Some thoughts on this would be nice, I don't want to make everything else that uses areas worse just because fire alarms are dumb, and I'm worried that's what I've ended up doing here. I've also added the portions of medbay/sci that jut out into the main hallway into the main hallway, I think? I could make these into lobby areas, but I'm not sure if that's appropriate or not. Adds a few windoors and airlocks to better section off portions of the station, this should reduce the amount of mass gas spreading that can occur. My goal here is to reduce the amount of uninteresting gas movement and make firelocks less hellish when there's a breach
This commit is contained in:
File diff suppressed because it is too large
Load Diff
File diff suppressed because it is too large
Load Diff
+2418
-2364
File diff suppressed because it is too large
Load Diff
@@ -399,6 +399,14 @@ NOTE: there are two lists of areas in the end of this file: centcom and station
|
||||
name = "Central Primary Hallway"
|
||||
icon_state = "hallC"
|
||||
|
||||
/area/hallway/primary/central/fore
|
||||
name = "Fore Central Primary Hallway"
|
||||
icon_state = "hallCF"
|
||||
|
||||
/area/hallway/primary/central/aft
|
||||
name = "Aft Cntral Primary Hallway"
|
||||
icon_state = "hallCA"
|
||||
|
||||
/area/hallway/primary/upper
|
||||
name = "Upper Central Primary Hallway"
|
||||
icon_state = "hallC"
|
||||
|
||||
Binary file not shown.
|
Before Width: | Height: | Size: 40 KiB After Width: | Height: | Size: 40 KiB |
Reference in New Issue
Block a user