mirror of
https://github.com/Bubberstation/Bubberstation.git
synced 2025-12-10 09:42:29 +00:00
[MIRROR] large refactor of machine/power code to cut down on processing time and wasted lists (#7920)
* large refactor of machine/power code to cut down on processing time and wasted lists (#60317) original pr here: #59789 (Closed because he didn't think it was good enough) came back to this because i realized that all machines were area sensitive, meaning they had a list with at least a reference to themselves (assuming they arent in the contents of another movable which most arent) for the purposes of handling power differences when their area changes pipes are machines there are ~14k machines and ~6k pipes i made this problem worse with a recent pr by making it a nested list so i needed to track what machines needed power, and this pr had work already done that could be used for that purpose. now machines that have use_power == NO_POWER_USE do not have this extra memory overhead for no reason currently every machine that uses power draws that amount from its area from a dynamic channel via auto_use_power() which is called every SSmachines fire(), then in apc/process() the area's dynamic power draw is reset and the power is used. with static power its not calculated then reset every loop, its just taken from the grid. so now machines handle updating their static power usage from their current area (this doesnt touch power machines that require a wire connection). in order to allow this, use_power, idle_power_usage, and active_power_usage have setters to track state correctly and update the static power usage on the machines current area and handle area sensitivity. also goes through a lot of heavy abusers of SSmachine processing time and tries to make it faster. makes airalarm/process() into a signal handler for COMSIG_TURF_EXPOSE since air alarms only need to process for changes. Why It's Good For The Game SSmachines isnt the heaviest hitter in terms of total cpu and certainly not in terms of overtime, but its not a lightweight. it frequently takes > 50ms to complete a run and seems to be in the top 5 or so of subsystem costs looking at some round profilers also gets rid of a few thousand lists since every pipe no longer has two useless lists each (and any other machines that dont use power) Love ya kyler Co-authored-by: Rohesie <rohesie@ gmail.com> * large refactor of machine/power code to cut down on processing time and wasted lists Co-authored-by: Kylerace <kylerlumpkin1@gmail.com> Co-authored-by: Rohesie <rohesie@ gmail.com>
This commit is contained in:
@@ -7,15 +7,20 @@
|
||||
#define AREA_USAGE_STATIC_LIGHT 5
|
||||
#define AREA_USAGE_STATIC_ENVIRON 6
|
||||
#define AREA_USAGE_LEN AREA_USAGE_STATIC_ENVIRON // largest idx
|
||||
|
||||
/// Index of the first dynamic usage channel
|
||||
#define AREA_USAGE_DYNAMIC_START AREA_USAGE_EQUIP
|
||||
/// Index of the last dynamic usage channel
|
||||
#define AREA_USAGE_DYNAMIC_END AREA_USAGE_ENVIRON
|
||||
|
||||
/// Index of the first static usage channel
|
||||
#define AREA_USAGE_STATIC_START AREA_USAGE_STATIC_EQUIP
|
||||
/// Index of the last static usage channel
|
||||
#define AREA_USAGE_STATIC_END AREA_USAGE_STATIC_ENVIRON
|
||||
|
||||
#define DYNAMIC_TO_STATIC_CHANNEL(dyn_channel) (dyn_channel + (AREA_USAGE_STATIC_START - AREA_USAGE_DYNAMIC_START))
|
||||
#define STATIC_TO_DYNAMIC_CHANNEL(static_channel) (static_channel - (AREA_USAGE_STATIC_START - AREA_USAGE_DYNAMIC_START))
|
||||
|
||||
|
||||
//Power use
|
||||
#define NO_POWER_USE 0
|
||||
@@ -196,3 +201,12 @@
|
||||
#define AIRALARM_BUILD_NO_WIRES 1
|
||||
/// Air alarm has all components but isn't completed
|
||||
#define AIRALARM_BUILD_COMPLETE 2
|
||||
|
||||
///TLV datums wont check limits set to this
|
||||
#define TLV_DONT_CHECK -1
|
||||
///the gas mixture is within the bounds of both warning and hazard limits
|
||||
#define TLV_NO_DANGER 0
|
||||
///the gas value is outside the warning limit but within the hazard limit, the air alarm will go into warning mode
|
||||
#define TLV_OUTSIDE_WARNING_LIMIT 1
|
||||
///the gas is outside the hazard limit, the air alarm will go into hazard mode
|
||||
#define TLV_OUTSIDE_HAZARD_LIMIT 2
|
||||
|
||||
@@ -13,25 +13,24 @@ SUBSYSTEM_DEF(machines)
|
||||
return ..()
|
||||
|
||||
/datum/controller/subsystem/machines/proc/makepowernets()
|
||||
for(var/datum/powernet/PN in powernets)
|
||||
qdel(PN)
|
||||
for(var/datum/powernet/power_network as anything in powernets)
|
||||
qdel(power_network)
|
||||
powernets.Cut()
|
||||
|
||||
for(var/obj/structure/cable/PC in GLOB.cable_list)
|
||||
if(!PC.powernet)
|
||||
var/datum/powernet/NewPN = new()
|
||||
NewPN.add_cable(PC)
|
||||
propagate_network(PC,PC.powernet)
|
||||
for(var/obj/structure/cable/power_cable as anything in GLOB.cable_list)
|
||||
if(!power_cable.powernet)
|
||||
var/datum/powernet/new_powernet = new()
|
||||
new_powernet.add_cable(power_cable)
|
||||
propagate_network(power_cable, power_cable.powernet)
|
||||
|
||||
/datum/controller/subsystem/machines/stat_entry(msg)
|
||||
msg = "M:[length(processing)]|PN:[length(powernets)]"
|
||||
return ..()
|
||||
|
||||
|
||||
/datum/controller/subsystem/machines/fire(resumed = FALSE)
|
||||
if (!resumed)
|
||||
for(var/datum/powernet/Powernet in powernets)
|
||||
Powernet.reset() //reset the power state.
|
||||
for(var/datum/powernet/powernet as anything in powernets)
|
||||
powernet.reset() //reset the power state.
|
||||
src.currentrun = processing.Copy()
|
||||
|
||||
//cache for sanic speed (lists are references anyways)
|
||||
@@ -40,13 +39,9 @@ SUBSYSTEM_DEF(machines)
|
||||
while(currentrun.len)
|
||||
var/obj/machinery/thing = currentrun[currentrun.len]
|
||||
currentrun.len--
|
||||
if(!QDELETED(thing) && thing.process(wait * 0.1) != PROCESS_KILL)
|
||||
if(thing.use_power)
|
||||
thing.auto_use_power() //add back the power state
|
||||
else
|
||||
if(QDELETED(thing) || thing.process(wait * 0.1) == PROCESS_KILL)
|
||||
processing -= thing
|
||||
if (!QDELETED(thing))
|
||||
thing.datum_flags &= ~DF_ISPROCESSING
|
||||
thing.datum_flags &= ~DF_ISPROCESSING
|
||||
if (MC_TICK_CHECK)
|
||||
return
|
||||
|
||||
|
||||
@@ -92,6 +92,9 @@
|
||||
///Used to decide what the maximum time between ambience is
|
||||
var/max_ambience_cooldown = 60 SECONDS //SKYRAT EDIT CHANGE - ORIGINAL: 90
|
||||
|
||||
var/list/air_vent_info = list()
|
||||
var/list/air_scrub_info = list()
|
||||
|
||||
/**
|
||||
* A list of teleport locations
|
||||
*
|
||||
@@ -432,8 +435,6 @@ GLOBAL_LIST_EMPTY(teleportlocs)
|
||||
* Updates the area icon, calls power change on all machinees in the area, and sends the `COMSIG_AREA_POWER_CHANGE` signal.
|
||||
*/
|
||||
/area/proc/power_change()
|
||||
for(var/obj/machinery/M in src) // for each machine in the area
|
||||
M.power_change() // reverify power status (to update icons etc.)
|
||||
SEND_SIGNAL(src, COMSIG_AREA_POWER_CHANGE)
|
||||
update_appearance()
|
||||
|
||||
@@ -452,13 +453,28 @@ GLOBAL_LIST_EMPTY(teleportlocs)
|
||||
power_usage[powerchannel] += value
|
||||
|
||||
/**
|
||||
* Clear all power usage in area
|
||||
* Remove a static amount of power load to an area
|
||||
*
|
||||
* Clears all power used for equipment, light and environment channels
|
||||
* Possible channels
|
||||
* *AREA_USAGE_STATIC_EQUIP
|
||||
* *AREA_USAGE_STATIC_LIGHT
|
||||
* *AREA_USAGE_STATIC_ENVIRON
|
||||
*/
|
||||
/area/proc/removeStaticPower(value, powerchannel)
|
||||
switch(powerchannel)
|
||||
if(AREA_USAGE_STATIC_START to AREA_USAGE_STATIC_END)
|
||||
power_usage[powerchannel] -= value
|
||||
|
||||
/**
|
||||
* Clear all non-static power usage in area
|
||||
*
|
||||
* Clears all power used for the dynamic equipment, light and environment channels
|
||||
*/
|
||||
/area/proc/clear_usage()
|
||||
for(var/i in AREA_USAGE_DYNAMIC_START to AREA_USAGE_DYNAMIC_END)
|
||||
power_usage[i] = 0
|
||||
power_usage[AREA_USAGE_EQUIP] = 0
|
||||
power_usage[AREA_USAGE_LIGHT] = 0
|
||||
power_usage[AREA_USAGE_ENVIRON] = 0
|
||||
|
||||
|
||||
/**
|
||||
* Add a power value amount to the stored used_x variables
|
||||
|
||||
@@ -5,7 +5,7 @@
|
||||
name = "bluespace gigabeacon"
|
||||
desc = "A device that draws power from bluespace and creates a permanent tracking beacon."
|
||||
layer = LOW_OBJ_LAYER
|
||||
use_power = IDLE_POWER_USE
|
||||
use_power = NO_POWER_USE
|
||||
idle_power_usage = 0
|
||||
var/obj/item/beacon/Beacon
|
||||
|
||||
|
||||
@@ -39,18 +39,22 @@
|
||||
* EMPED -- temporary broken by EMP pulse
|
||||
*
|
||||
*Class Procs:
|
||||
* Initialize() 'game/machinery/machine.dm'
|
||||
* Initialize()
|
||||
*
|
||||
* Destroy() 'game/machinery/machine.dm'
|
||||
* Destroy()
|
||||
*
|
||||
* auto_use_power() 'game/machinery/machine.dm'
|
||||
* This proc determines how power mode power is deducted by the machine.
|
||||
* 'auto_use_power()' is called by the 'master_controller' game_controller every
|
||||
* tick.
|
||||
* update_mode_power_usage()
|
||||
* updates the static_power_usage var of this machine and makes its static power usage from its area accurate.
|
||||
* called after the idle or active power usage has been changed.
|
||||
*
|
||||
* update_power_channel()
|
||||
* updates the static_power_usage var of this machine and makes its static power usage from its area accurate.
|
||||
* called after the power_channel var has been changed or called to change the var itself.
|
||||
*
|
||||
* unset_static_power()
|
||||
* completely removes the current static power usage of this machine from its area.
|
||||
* used in the other power updating procs to then readd the correct power usage.
|
||||
*
|
||||
* Return Value:
|
||||
* return:1 -- if object is powered
|
||||
* return:0 -- if object is not powered.
|
||||
*
|
||||
* Default definition uses 'use_power', 'power_channel', 'active_power_usage',
|
||||
* 'idle_power_usage', 'powered()', and 'use_power()' implement behavior.
|
||||
@@ -99,11 +103,15 @@
|
||||
|
||||
var/machine_stat = NONE
|
||||
var/use_power = IDLE_POWER_USE
|
||||
//0 = dont run the auto
|
||||
//1 = run auto, use idle
|
||||
//2 = run auto, use active
|
||||
//0 = dont use power
|
||||
//1 = use idle_power_usage
|
||||
//2 = use active_power_usage
|
||||
///the amount of static power load this machine adds to its area's power_usage list when use_power = IDLE_POWER_USE
|
||||
var/idle_power_usage = 0
|
||||
///the amount of static power load this machine adds to its area's power_usage list when use_power = ACTIVE_POWER_USE
|
||||
var/active_power_usage = 0
|
||||
///the current amount of static power usage this machine is taking from its area
|
||||
var/static_power_usage = 0
|
||||
var/power_channel = AREA_USAGE_EQUIP
|
||||
//AREA_USAGE_EQUIP,AREA_USAGE_ENVIRON or AREA_USAGE_LIGHT
|
||||
///A combination of factors such as having power, not being broken and so on. Boolean.
|
||||
@@ -154,6 +162,63 @@
|
||||
|
||||
return INITIALIZE_HINT_LATELOAD
|
||||
|
||||
/obj/machinery/LateInitialize()
|
||||
. = ..()
|
||||
power_change()
|
||||
if(use_power == NO_POWER_USE)
|
||||
return
|
||||
|
||||
update_current_power_usage()
|
||||
setup_area_power_relationship()
|
||||
|
||||
/obj/machinery/Destroy()
|
||||
GLOB.machines.Remove(src)
|
||||
end_processing()
|
||||
dump_inventory_contents()
|
||||
QDEL_LIST(component_parts)
|
||||
QDEL_NULL(circuit)
|
||||
unset_static_power()
|
||||
return ..()
|
||||
|
||||
/**
|
||||
* proc to call when the machine starts to require power after a duration of not requiring power
|
||||
* sets up power related connections to its area if it exists and becomes area sensitive
|
||||
* does not affect power usage itself
|
||||
*/
|
||||
/obj/machinery/proc/setup_area_power_relationship()
|
||||
become_area_sensitive(INNATE_TRAIT)
|
||||
|
||||
var/area/our_area = get_area(src)
|
||||
if(our_area)
|
||||
RegisterSignal(our_area, COMSIG_AREA_POWER_CHANGE, .proc/power_change)
|
||||
RegisterSignal(src, COMSIG_ENTER_AREA, .proc/on_enter_area)
|
||||
RegisterSignal(src, COMSIG_EXIT_AREA, .proc/on_exit_area)
|
||||
|
||||
/**
|
||||
* proc to call when the machine stops requiring power after a duration of requiring power
|
||||
* saves memory by removing the power relationship with its area if it exists and loses area sensitivity
|
||||
* does not affect power usage itself
|
||||
*/
|
||||
/obj/machinery/proc/remove_area_power_relationship()
|
||||
var/area/our_area = get_area(src)
|
||||
if(our_area)
|
||||
UnregisterSignal(our_area, COMSIG_AREA_POWER_CHANGE)
|
||||
|
||||
REMOVE_TRAIT(src, TRAIT_AREA_SENSITIVE, INNATE_TRAIT)
|
||||
UnregisterSignal(src, COMSIG_ENTER_AREA)
|
||||
UnregisterSignal(src, COMSIG_EXIT_AREA)
|
||||
|
||||
/obj/machinery/proc/on_enter_area(datum/source, area/area_to_register)
|
||||
SIGNAL_HANDLER
|
||||
update_current_power_usage()
|
||||
power_change()
|
||||
RegisterSignal(area_to_register, COMSIG_AREA_POWER_CHANGE, .proc/power_change)
|
||||
|
||||
/obj/machinery/proc/on_exit_area(datum/source, area/area_to_unregister)
|
||||
SIGNAL_HANDLER
|
||||
unset_static_power()
|
||||
UnregisterSignal(area_to_unregister, COMSIG_AREA_POWER_CHANGE)
|
||||
|
||||
/obj/machinery/proc/set_occupant(atom/movable/new_occupant)
|
||||
SHOULD_CALL_PARENT(TRUE)
|
||||
|
||||
@@ -170,20 +235,6 @@
|
||||
var/datum/controller/subsystem/processing/subsystem = locate(subsystem_type) in Master.subsystems
|
||||
STOP_PROCESSING(subsystem, src)
|
||||
|
||||
/obj/machinery/LateInitialize()
|
||||
. = ..()
|
||||
power_change()
|
||||
become_area_sensitive(ROUNDSTART_TRAIT)
|
||||
RegisterSignal(src, COMSIG_ENTER_AREA, .proc/power_change)
|
||||
|
||||
/obj/machinery/Destroy()
|
||||
GLOB.machines.Remove(src)
|
||||
end_processing()
|
||||
dump_inventory_contents()
|
||||
QDEL_LIST(component_parts)
|
||||
QDEL_NULL(circuit)
|
||||
return ..()
|
||||
|
||||
/obj/machinery/proc/locate_machinery()
|
||||
return
|
||||
|
||||
@@ -315,15 +366,119 @@
|
||||
updateUsrDialog()
|
||||
update_appearance()
|
||||
|
||||
/obj/machinery/proc/auto_use_power()
|
||||
if(!powered(power_channel))
|
||||
///updates the use_power var for this machine and updates its static power usage from its area to reflect the new value
|
||||
/obj/machinery/proc/update_use_power(new_use_power)
|
||||
SHOULD_CALL_PARENT(TRUE)
|
||||
if(new_use_power == use_power)
|
||||
return FALSE
|
||||
if(use_power == IDLE_POWER_USE)
|
||||
use_power(idle_power_usage,power_channel)
|
||||
else if(use_power >= ACTIVE_POWER_USE)
|
||||
use_power(active_power_usage,power_channel)
|
||||
|
||||
unset_static_power()
|
||||
|
||||
var/new_usage = 0
|
||||
switch(new_use_power)
|
||||
if(IDLE_POWER_USE)
|
||||
new_usage = idle_power_usage
|
||||
if(ACTIVE_POWER_USE)
|
||||
new_usage = active_power_usage
|
||||
|
||||
if(use_power == NO_POWER_USE)
|
||||
setup_area_power_relationship()
|
||||
else if(new_use_power == NO_POWER_USE)
|
||||
remove_area_power_relationship()
|
||||
|
||||
static_power_usage = new_usage
|
||||
|
||||
if(new_usage)
|
||||
var/area/our_area = get_area(src)
|
||||
our_area?.addStaticPower(new_usage, DYNAMIC_TO_STATIC_CHANNEL(power_channel))
|
||||
|
||||
use_power = new_use_power
|
||||
|
||||
return TRUE
|
||||
|
||||
///updates the power channel this machine uses. removes the static power usage from the old channel and readds it to the new channel
|
||||
/obj/machinery/proc/update_power_channel(new_power_channel)
|
||||
SHOULD_CALL_PARENT(TRUE)
|
||||
if(new_power_channel == power_channel)
|
||||
return FALSE
|
||||
|
||||
var/usage = unset_static_power()
|
||||
|
||||
var/area/our_area = get_area(src)
|
||||
|
||||
if(our_area && usage)
|
||||
our_area.addStaticPower(usage, DYNAMIC_TO_STATIC_CHANNEL(new_power_channel))
|
||||
|
||||
power_channel = new_power_channel
|
||||
|
||||
return TRUE
|
||||
|
||||
///internal proc that removes all static power usage from the current area
|
||||
/obj/machinery/proc/unset_static_power()
|
||||
SHOULD_NOT_OVERRIDE(TRUE)
|
||||
var/old_usage = static_power_usage
|
||||
|
||||
var/area/our_area = get_area(src)
|
||||
|
||||
if(our_area && old_usage)
|
||||
our_area.removeStaticPower(old_usage, DYNAMIC_TO_STATIC_CHANNEL(power_channel))
|
||||
static_power_usage = 0
|
||||
|
||||
return old_usage
|
||||
|
||||
/**
|
||||
* sets the power_usage linked to the specified use_power_mode to new_usage
|
||||
* e.g. update_mode_power_usage(ACTIVE_POWER_USE, 10) sets active_power_use = 10 and updates its power draw from the machines area if use_power == ACTIVE_POWER_USE
|
||||
*
|
||||
* Arguments:
|
||||
* * use_power_mode - the use_power power mode to change. if IDLE_POWER_USE changes idle_power_usage, ACTIVE_POWER_USE changes active_power_usage
|
||||
* * new_usage - the new value to set the specified power mode var to
|
||||
*/
|
||||
/obj/machinery/proc/update_mode_power_usage(use_power_mode, new_usage)
|
||||
SHOULD_CALL_PARENT(TRUE)
|
||||
if(use_power_mode == NO_POWER_USE)
|
||||
stack_trace("trying to set the power usage associated with NO_POWER_USE in update_mode_power_usage()!")
|
||||
return FALSE
|
||||
|
||||
unset_static_power() //completely remove our static_power_usage from our area, then readd new_usage
|
||||
|
||||
switch(use_power_mode)
|
||||
if(IDLE_POWER_USE)
|
||||
idle_power_usage = new_usage
|
||||
if(ACTIVE_POWER_USE)
|
||||
active_power_usage = new_usage
|
||||
|
||||
if(use_power_mode == use_power)
|
||||
static_power_usage = new_usage
|
||||
|
||||
var/area/our_area = get_area(src)
|
||||
|
||||
if(our_area)
|
||||
our_area.addStaticPower(static_power_usage, DYNAMIC_TO_STATIC_CHANNEL(power_channel))
|
||||
|
||||
return TRUE
|
||||
|
||||
///makes this machine draw power from its area according to which use_power mode it is set to
|
||||
/obj/machinery/proc/update_current_power_usage()
|
||||
if(static_power_usage)
|
||||
unset_static_power()
|
||||
|
||||
var/area/our_area = get_area(src)
|
||||
if(!our_area)
|
||||
return FALSE
|
||||
|
||||
switch(use_power)
|
||||
if(IDLE_POWER_USE)
|
||||
static_power_usage = idle_power_usage
|
||||
if(ACTIVE_POWER_USE)
|
||||
static_power_usage = active_power_usage
|
||||
if(NO_POWER_USE)
|
||||
return
|
||||
|
||||
if(static_power_usage)
|
||||
our_area.addStaticPower(static_power_usage, DYNAMIC_TO_STATIC_CHANNEL(power_channel))
|
||||
|
||||
return TRUE
|
||||
|
||||
///Called when we want to change the value of the `is_operational` variable. Boolean.
|
||||
/obj/machinery/proc/set_is_operational(new_value)
|
||||
|
||||
@@ -67,23 +67,20 @@
|
||||
..()
|
||||
|
||||
/obj/machinery/dish_drive/RefreshParts()
|
||||
idle_power_usage = initial(idle_power_usage)
|
||||
active_power_usage = initial(active_power_usage)
|
||||
use_power = initial(use_power)
|
||||
var/total_rating = 0
|
||||
for(var/obj/item/stock_parts/S in component_parts)
|
||||
total_rating += S.rating
|
||||
if(total_rating >= 9)
|
||||
active_power_usage = 0
|
||||
use_power = NO_POWER_USE
|
||||
update_mode_power_usage(ACTIVE_POWER_USE, 0)
|
||||
else
|
||||
idle_power_usage = max(0, idle_power_usage - total_rating)
|
||||
active_power_usage = max(0, active_power_usage - total_rating)
|
||||
update_mode_power_usage(IDLE_POWER_USE, max(0, initial(idle_power_usage) - total_rating))
|
||||
update_mode_power_usage(ACTIVE_POWER_USE, max(0, initial(active_power_usage) - total_rating))
|
||||
var/obj/item/circuitboard/machine/dish_drive/board = locate() in component_parts
|
||||
if(board)
|
||||
suction_enabled = board.suction
|
||||
transmit_enabled = board.transmit
|
||||
|
||||
|
||||
/obj/machinery/dish_drive/process()
|
||||
if(time_since_dishes <= world.time && transmit_enabled)
|
||||
do_the_dishes()
|
||||
|
||||
@@ -434,12 +434,7 @@ Possible to do for anyone motivated enough:
|
||||
|
||||
/obj/machinery/holopad/process()
|
||||
if(LAZYLEN(masters))
|
||||
for(var/I in masters)
|
||||
var/mob/living/master = I
|
||||
var/mob/living/silicon/ai/AI = master
|
||||
if(!istype(AI))
|
||||
AI = null
|
||||
|
||||
for(var/mob/living/master as anything in masters)
|
||||
if(!is_operational || !validate_user(master))
|
||||
clear_holo(master)
|
||||
|
||||
@@ -448,22 +443,23 @@ Possible to do for anyone motivated enough:
|
||||
|
||||
ringing = FALSE
|
||||
|
||||
for(var/I in holo_calls)
|
||||
var/datum/holocall/HC = I
|
||||
if(HC.connected_holopad != src)
|
||||
if(force_answer_call && world.time > (HC.call_start_time + (HOLOPAD_MAX_DIAL_TIME / 2)))
|
||||
HC.Answer(src)
|
||||
break
|
||||
if(HC.head_call && !secure)
|
||||
HC.Answer(src)
|
||||
break
|
||||
if(outgoing_call)
|
||||
HC.Disconnect(src)//can't answer calls while calling
|
||||
else
|
||||
playsound(src, 'sound/machines/twobeep.ogg', 100) //bring, bring!
|
||||
ringing = TRUE
|
||||
for(var/datum/holocall/holocall as anything in holo_calls)
|
||||
if(holocall.connected_holopad == src)
|
||||
continue
|
||||
|
||||
update_appearance()
|
||||
if(force_answer_call && world.time > (holocall.call_start_time + (HOLOPAD_MAX_DIAL_TIME / 2)))
|
||||
holocall.Answer(src)
|
||||
break
|
||||
if(holocall.head_call && !secure)
|
||||
holocall.Answer(src)
|
||||
break
|
||||
if(outgoing_call)
|
||||
holocall.Disconnect(src)//can't answer calls while calling
|
||||
else
|
||||
playsound(src, 'sound/machines/twobeep.ogg', 100) //bring, bring!
|
||||
ringing = TRUE
|
||||
|
||||
update_appearance(UPDATE_ICON_STATE)
|
||||
|
||||
/obj/machinery/holopad/proc/activate_holo(mob/living/user)
|
||||
var/mob/living/silicon/ai/AI = user
|
||||
@@ -527,8 +523,8 @@ For the other part of the code, check silicon say.dm. Particularly robot talk.*/
|
||||
|
||||
/obj/machinery/holopad/proc/SetLightsAndPower()
|
||||
var/total_users = LAZYLEN(masters) + LAZYLEN(holo_calls)
|
||||
use_power = total_users > 0 ? ACTIVE_POWER_USE : IDLE_POWER_USE
|
||||
active_power_usage = HOLOPAD_PASSIVE_POWER_USAGE + (HOLOGRAM_POWER_USAGE * total_users)
|
||||
update_use_power(total_users > 0 ? ACTIVE_POWER_USE : IDLE_POWER_USE)
|
||||
update_mode_power_usage(ACTIVE_POWER_USE, HOLOPAD_PASSIVE_POWER_USAGE + (HOLOGRAM_POWER_USAGE * total_users))
|
||||
if(total_users || replay_mode)
|
||||
set_light(2)
|
||||
else
|
||||
|
||||
@@ -3,7 +3,7 @@
|
||||
desc = "A bluespace pad able to thrust matter through bluespace, teleporting it to or from nearby locations."
|
||||
icon = 'icons/obj/telescience.dmi'
|
||||
icon_state = "lpad-idle"
|
||||
use_power = TRUE
|
||||
use_power = IDLE_POWER_USE
|
||||
idle_power_usage = 200
|
||||
active_power_usage = 2500
|
||||
hud_possible = list(DIAG_LAUNCHPAD_HUD)
|
||||
@@ -212,7 +212,7 @@
|
||||
icon_state = "blpad-idle"
|
||||
icon_teleport = "blpad-beam"
|
||||
anchored = FALSE
|
||||
use_power = FALSE
|
||||
use_power = IDLE_POWER_USE
|
||||
idle_power_usage = 0
|
||||
active_power_usage = 0
|
||||
teleport_speed = 20
|
||||
|
||||
@@ -47,12 +47,12 @@
|
||||
charging = new_charging
|
||||
if (new_charging)
|
||||
START_PROCESSING(SSmachines, src)
|
||||
update_use_power(ACTIVE_POWER_USE)
|
||||
finished_recharging = FALSE
|
||||
use_power = ACTIVE_POWER_USE
|
||||
using_power = TRUE
|
||||
update_appearance()
|
||||
else
|
||||
use_power = IDLE_POWER_USE
|
||||
update_use_power(IDLE_POWER_USE)
|
||||
using_power = FALSE
|
||||
update_appearance()
|
||||
|
||||
|
||||
@@ -90,12 +90,12 @@
|
||||
|
||||
/obj/machinery/recharge_station/open_machine()
|
||||
. = ..()
|
||||
use_power = IDLE_POWER_USE
|
||||
update_use_power(IDLE_POWER_USE)
|
||||
|
||||
/obj/machinery/recharge_station/close_machine()
|
||||
. = ..()
|
||||
if(occupant)
|
||||
use_power = ACTIVE_POWER_USE //It always tries to charge, even if it can't.
|
||||
update_use_power(ACTIVE_POWER_USE) //It always tries to charge, even if it can't.
|
||||
add_fingerprint(occupant)
|
||||
|
||||
/obj/machinery/recharge_station/update_icon_state()
|
||||
|
||||
@@ -108,13 +108,13 @@
|
||||
target.apply_status_effect(STATUS_EFFECT_STASIS, STASIS_MACHINE_EFFECT)
|
||||
ADD_TRAIT(target, TRAIT_TUMOR_SUPPRESSED, TRAIT_GENERIC)
|
||||
target.extinguish_mob()
|
||||
use_power = ACTIVE_POWER_USE
|
||||
update_use_power(ACTIVE_POWER_USE)
|
||||
|
||||
/obj/machinery/stasis/proc/thaw_them(mob/living/target)
|
||||
target.remove_status_effect(STATUS_EFFECT_STASIS, STASIS_MACHINE_EFFECT)
|
||||
REMOVE_TRAIT(target, TRAIT_TUMOR_SUPPRESSED, TRAIT_GENERIC)
|
||||
if(target == occupant)
|
||||
use_power = IDLE_POWER_USE
|
||||
update_use_power(IDLE_POWER_USE)
|
||||
|
||||
/obj/machinery/stasis/post_buckle_mob(mob/living/L)
|
||||
if(!can_be_occupant(L))
|
||||
@@ -131,8 +131,8 @@
|
||||
update_appearance()
|
||||
|
||||
/obj/machinery/stasis/process()
|
||||
if( !( occupant && isliving(occupant) && check_nap_violations() ) )
|
||||
use_power = IDLE_POWER_USE
|
||||
if(!(occupant && isliving(occupant) && check_nap_violations()))
|
||||
update_use_power(IDLE_POWER_USE)
|
||||
return
|
||||
var/mob/living/L_occupant = occupant
|
||||
if(stasis_running())
|
||||
|
||||
@@ -63,10 +63,7 @@
|
||||
return ..()
|
||||
|
||||
/obj/machinery/ntnet_relay/process(delta_time)
|
||||
if(is_operational)
|
||||
use_power = ACTIVE_POWER_USE
|
||||
else
|
||||
use_power = IDLE_POWER_USE
|
||||
update_use_power(is_operational ? ACTIVE_POWER_USE : IDLE_POWER_USE)
|
||||
|
||||
update_appearance()
|
||||
|
||||
|
||||
@@ -1,37 +1,43 @@
|
||||
// A datum for dealing with threshold limit values
|
||||
/datum/tlv
|
||||
var/min2
|
||||
var/min1
|
||||
var/max1
|
||||
var/max2
|
||||
var/warning_min
|
||||
var/warning_max
|
||||
var/hazard_min
|
||||
var/hazard_max
|
||||
|
||||
/datum/tlv/New(min2 as num, min1 as num, max1 as num, max2 as num)
|
||||
if(min2) src.min2 = min2
|
||||
if(min1) src.min1 = min1
|
||||
if(max1) src.max1 = max1
|
||||
if(max2) src.max2 = max2
|
||||
if(min2)
|
||||
hazard_min = min2
|
||||
if(min1)
|
||||
warning_min = min1
|
||||
if(max1)
|
||||
warning_max = max1
|
||||
if(max2)
|
||||
hazard_max = max2
|
||||
|
||||
/datum/tlv/proc/get_danger_level(val as num)
|
||||
if(max2 != -1 && val >= max2)
|
||||
return 2
|
||||
if(min2 != -1 && val <= min2)
|
||||
return 2
|
||||
if(max1 != -1 && val >= max1)
|
||||
return 1
|
||||
if(min1 != -1 && val <= min1)
|
||||
return 1
|
||||
return 0
|
||||
/datum/tlv/proc/get_danger_level(val)
|
||||
if(hazard_max != TLV_DONT_CHECK && val >= hazard_max)
|
||||
return TLV_OUTSIDE_HAZARD_LIMIT
|
||||
if(hazard_min != TLV_DONT_CHECK && val <= hazard_min)
|
||||
return TLV_OUTSIDE_HAZARD_LIMIT
|
||||
if(warning_max != TLV_DONT_CHECK && val >= warning_max)
|
||||
return TLV_OUTSIDE_WARNING_LIMIT
|
||||
if(warning_min != TLV_DONT_CHECK && val <= warning_min)
|
||||
return TLV_OUTSIDE_WARNING_LIMIT
|
||||
|
||||
return TLV_NO_DANGER
|
||||
|
||||
/datum/tlv/no_checks
|
||||
min2 = -1
|
||||
min1 = -1
|
||||
max1 = -1
|
||||
max2 = -1
|
||||
hazard_min = TLV_DONT_CHECK
|
||||
warning_min = TLV_DONT_CHECK
|
||||
warning_max = TLV_DONT_CHECK
|
||||
hazard_max = TLV_DONT_CHECK
|
||||
|
||||
/datum/tlv/dangerous
|
||||
min2 = -1
|
||||
min1 = -1
|
||||
max1 = 0.2
|
||||
max2 = 0.5
|
||||
hazard_min = TLV_DONT_CHECK
|
||||
warning_min = TLV_DONT_CHECK
|
||||
warning_max = 0.2
|
||||
hazard_max = 0.5
|
||||
|
||||
/obj/item/electronics/airalarm
|
||||
name = "air alarm electronics"
|
||||
@@ -85,8 +91,10 @@
|
||||
///Represents a signel source of atmos alarms, complains to all the listeners if one of our thresholds is violated
|
||||
var/datum/alarm_handler/alarm_manager
|
||||
|
||||
var/static/list/atmos_connections = list(COMSIG_TURF_EXPOSE = .proc/check_air_dangerlevel)
|
||||
|
||||
var/list/TLV = list( // Breathable air.
|
||||
"pressure" = new/datum/tlv(HAZARD_LOW_PRESSURE, WARNING_LOW_PRESSURE, WARNING_HIGH_PRESSURE, HAZARD_HIGH_PRESSURE), // kPa. Values are min2, min1, max1, max2
|
||||
"pressure" = new/datum/tlv(HAZARD_LOW_PRESSURE, WARNING_LOW_PRESSURE, WARNING_HIGH_PRESSURE, HAZARD_HIGH_PRESSURE), // kPa. Values are hazard_min, warning_min, warning_max, hazard_max
|
||||
"temperature" = new/datum/tlv(BODYTEMP_COLD_WARNING_1, BODYTEMP_COLD_WARNING_1+10, BODYTEMP_HEAT_WARNING_1-27, BODYTEMP_HEAT_WARNING_1),
|
||||
/datum/gas/oxygen = new/datum/tlv(16, 19, 135, 140), // Partial pressure, kpa
|
||||
/datum/gas/nitrogen = new/datum/tlv(-1, -1, 1000, 1000),
|
||||
@@ -111,109 +119,6 @@
|
||||
/datum/gas/halon = new/datum/tlv/dangerous
|
||||
)
|
||||
|
||||
/obj/machinery/airalarm/server // No checks here.
|
||||
TLV = list(
|
||||
"pressure" = new/datum/tlv/no_checks,
|
||||
"temperature" = new/datum/tlv/no_checks,
|
||||
/datum/gas/oxygen = new/datum/tlv/no_checks,
|
||||
/datum/gas/nitrogen = new/datum/tlv/no_checks,
|
||||
/datum/gas/carbon_dioxide = new/datum/tlv/no_checks,
|
||||
/datum/gas/miasma = new/datum/tlv/no_checks,
|
||||
/datum/gas/plasma = new/datum/tlv/no_checks,
|
||||
/datum/gas/nitrous_oxide = new/datum/tlv/no_checks,
|
||||
/datum/gas/bz = new/datum/tlv/no_checks,
|
||||
/datum/gas/hypernoblium = new/datum/tlv/no_checks,
|
||||
/datum/gas/water_vapor = new/datum/tlv/no_checks,
|
||||
/datum/gas/tritium = new/datum/tlv/no_checks,
|
||||
/datum/gas/stimulum = new/datum/tlv/no_checks,
|
||||
/datum/gas/nitryl = new/datum/tlv/no_checks,
|
||||
/datum/gas/pluoxium = new/datum/tlv/no_checks,
|
||||
/datum/gas/freon = new/datum/tlv/no_checks,
|
||||
/datum/gas/hydrogen = new/datum/tlv/no_checks,
|
||||
/datum/gas/healium = new/datum/tlv/dangerous,
|
||||
/datum/gas/proto_nitrate = new/datum/tlv/dangerous,
|
||||
/datum/gas/zauker = new/datum/tlv/dangerous,
|
||||
/datum/gas/helium = new/datum/tlv/dangerous,
|
||||
/datum/gas/antinoblium = new/datum/tlv/dangerous,
|
||||
/datum/gas/halon = new/datum/tlv/dangerous
|
||||
)
|
||||
|
||||
/obj/machinery/airalarm/kitchen_cold_room // Kitchen cold rooms start off at -14°C or 259.15K.
|
||||
TLV = list(
|
||||
"pressure" = new/datum/tlv(ONE_ATMOSPHERE * 0.8, ONE_ATMOSPHERE * 0.9, ONE_ATMOSPHERE * 1.1, ONE_ATMOSPHERE * 1.2), // kPa
|
||||
"temperature" = new/datum/tlv(COLD_ROOM_TEMP-40, COLD_ROOM_TEMP-20, COLD_ROOM_TEMP+20, COLD_ROOM_TEMP+40),
|
||||
/datum/gas/oxygen = new/datum/tlv(16, 19, 135, 140), // Partial pressure, kpa
|
||||
/datum/gas/nitrogen = new/datum/tlv(-1, -1, 1000, 1000),
|
||||
/datum/gas/carbon_dioxide = new/datum/tlv(-1, -1, 5, 10),
|
||||
/datum/gas/miasma = new/datum/tlv/(-1, -1, 2, 5),
|
||||
/datum/gas/plasma = new/datum/tlv/dangerous,
|
||||
/datum/gas/nitrous_oxide = new/datum/tlv/dangerous,
|
||||
/datum/gas/bz = new/datum/tlv/dangerous,
|
||||
/datum/gas/hypernoblium = new/datum/tlv(-1, -1, 1000, 1000), // Hyper-Noblium is inert and nontoxic
|
||||
/datum/gas/water_vapor = new/datum/tlv/dangerous,
|
||||
/datum/gas/tritium = new/datum/tlv/dangerous,
|
||||
/datum/gas/stimulum = new/datum/tlv/dangerous,
|
||||
/datum/gas/nitryl = new/datum/tlv/dangerous,
|
||||
/datum/gas/pluoxium = new/datum/tlv(-1, -1, 1000, 1000), // Unlike oxygen, pluoxium does not fuel plasma/tritium fires
|
||||
/datum/gas/freon = new/datum/tlv/dangerous,
|
||||
/datum/gas/hydrogen = new/datum/tlv/dangerous,
|
||||
/datum/gas/healium = new/datum/tlv/dangerous,
|
||||
/datum/gas/proto_nitrate = new/datum/tlv/dangerous,
|
||||
/datum/gas/zauker = new/datum/tlv/dangerous,
|
||||
/datum/gas/helium = new/datum/tlv/dangerous,
|
||||
/datum/gas/antinoblium = new/datum/tlv/dangerous,
|
||||
/datum/gas/halon = new/datum/tlv/dangerous
|
||||
)
|
||||
|
||||
/obj/machinery/airalarm/unlocked
|
||||
locked = FALSE
|
||||
|
||||
/obj/machinery/airalarm/engine
|
||||
name = "engine air alarm"
|
||||
locked = FALSE
|
||||
req_access = null
|
||||
req_one_access = list(ACCESS_ATMOSPHERICS, ACCESS_ENGINE)
|
||||
|
||||
/obj/machinery/airalarm/mixingchamber
|
||||
name = "chamber air alarm"
|
||||
locked = FALSE
|
||||
req_access = null
|
||||
req_one_access = list(ACCESS_ATMOSPHERICS, ACCESS_ORDNANCE)
|
||||
|
||||
/obj/machinery/airalarm/all_access
|
||||
name = "all-access air alarm"
|
||||
desc = "This particular atmos control unit appears to have no access restrictions."
|
||||
locked = FALSE
|
||||
req_access = null
|
||||
req_one_access = null
|
||||
|
||||
/obj/machinery/airalarm/syndicate //general syndicate access
|
||||
req_access = list(ACCESS_SYNDICATE)
|
||||
|
||||
/obj/machinery/airalarm/away //general away mission access
|
||||
req_access = list(ACCESS_AWAY_GENERAL)
|
||||
|
||||
/obj/machinery/airalarm/directional/north //Pixel offsets get overwritten on New()
|
||||
dir = SOUTH
|
||||
pixel_y = 24
|
||||
|
||||
/obj/machinery/airalarm/directional/south
|
||||
dir = NORTH
|
||||
pixel_y = -24
|
||||
|
||||
/obj/machinery/airalarm/directional/east
|
||||
dir = WEST
|
||||
pixel_x = 24
|
||||
|
||||
/obj/machinery/airalarm/directional/west
|
||||
dir = EAST
|
||||
pixel_x = -24
|
||||
|
||||
//all air alarms in area are connected via magic
|
||||
/area
|
||||
var/list/air_vent_info = list()
|
||||
var/list/air_scrub_info = list()
|
||||
|
||||
/obj/machinery/airalarm/New(loc, ndir, nbuild)
|
||||
..()
|
||||
wires = new /datum/wires/airalarm(src)
|
||||
@@ -241,6 +146,7 @@
|
||||
/obj/machinery/airalarm/Initialize(mapload)
|
||||
. = ..()
|
||||
set_frequency(frequency)
|
||||
AddElement(/datum/element/connect_loc, atmos_connections)
|
||||
AddComponent(/datum/component/usb_port, list(
|
||||
/obj/item/circuit_component/air_alarm,
|
||||
))
|
||||
@@ -367,27 +273,27 @@
|
||||
|
||||
selected = TLV["pressure"]
|
||||
thresholds += list(list("name" = "Pressure", "settings" = list()))
|
||||
thresholds[thresholds.len]["settings"] += list(list("env" = "pressure", "val" = "min2", "selected" = selected.min2))
|
||||
thresholds[thresholds.len]["settings"] += list(list("env" = "pressure", "val" = "min1", "selected" = selected.min1))
|
||||
thresholds[thresholds.len]["settings"] += list(list("env" = "pressure", "val" = "max1", "selected" = selected.max1))
|
||||
thresholds[thresholds.len]["settings"] += list(list("env" = "pressure", "val" = "max2", "selected" = selected.max2))
|
||||
thresholds[thresholds.len]["settings"] += list(list("env" = "pressure", "val" = "hazard_min", "selected" = selected.hazard_min))
|
||||
thresholds[thresholds.len]["settings"] += list(list("env" = "pressure", "val" = "warning_min", "selected" = selected.warning_min))
|
||||
thresholds[thresholds.len]["settings"] += list(list("env" = "pressure", "val" = "warning_max", "selected" = selected.warning_max))
|
||||
thresholds[thresholds.len]["settings"] += list(list("env" = "pressure", "val" = "hazard_max", "selected" = selected.hazard_max))
|
||||
|
||||
selected = TLV["temperature"]
|
||||
thresholds += list(list("name" = "Temperature", "settings" = list()))
|
||||
thresholds[thresholds.len]["settings"] += list(list("env" = "temperature", "val" = "min2", "selected" = selected.min2))
|
||||
thresholds[thresholds.len]["settings"] += list(list("env" = "temperature", "val" = "min1", "selected" = selected.min1))
|
||||
thresholds[thresholds.len]["settings"] += list(list("env" = "temperature", "val" = "max1", "selected" = selected.max1))
|
||||
thresholds[thresholds.len]["settings"] += list(list("env" = "temperature", "val" = "max2", "selected" = selected.max2))
|
||||
thresholds[thresholds.len]["settings"] += list(list("env" = "temperature", "val" = "hazard_min", "selected" = selected.hazard_min))
|
||||
thresholds[thresholds.len]["settings"] += list(list("env" = "temperature", "val" = "warning_min", "selected" = selected.warning_min))
|
||||
thresholds[thresholds.len]["settings"] += list(list("env" = "temperature", "val" = "warning_max", "selected" = selected.warning_max))
|
||||
thresholds[thresholds.len]["settings"] += list(list("env" = "temperature", "val" = "hazard_max", "selected" = selected.hazard_max))
|
||||
|
||||
for(var/gas_id in GLOB.meta_gas_info)
|
||||
if(!(gas_id in TLV)) // We're not interested in this gas, it seems.
|
||||
continue
|
||||
selected = TLV[gas_id]
|
||||
thresholds += list(list("name" = GLOB.meta_gas_info[gas_id][META_GAS_NAME], "settings" = list()))
|
||||
thresholds[thresholds.len]["settings"] += list(list("env" = gas_id, "val" = "min2", "selected" = selected.min2))
|
||||
thresholds[thresholds.len]["settings"] += list(list("env" = gas_id, "val" = "min1", "selected" = selected.min1))
|
||||
thresholds[thresholds.len]["settings"] += list(list("env" = gas_id, "val" = "max1", "selected" = selected.max1))
|
||||
thresholds[thresholds.len]["settings"] += list(list("env" = gas_id, "val" = "max2", "selected" = selected.max2))
|
||||
thresholds[thresholds.len]["settings"] += list(list("env" = gas_id, "val" = "hazard_min", "selected" = selected.hazard_min))
|
||||
thresholds[thresholds.len]["settings"] += list(list("env" = gas_id, "val" = "warning_min", "selected" = selected.warning_min))
|
||||
thresholds[thresholds.len]["settings"] += list(list("env" = gas_id, "val" = "warning_max", "selected" = selected.warning_max))
|
||||
thresholds[thresholds.len]["settings"] += list(list("env" = gas_id, "val" = "hazard_max", "selected" = selected.hazard_max))
|
||||
|
||||
data["thresholds"] = thresholds
|
||||
return data
|
||||
@@ -441,6 +347,9 @@
|
||||
else
|
||||
tlv.vars[name] = round(value, 0.01)
|
||||
investigate_log(" treshold value for [env]:[name] was set to [value] by [key_name(usr)]",INVESTIGATE_ATMOS)
|
||||
var/turf/our_turf = get_turf(src)
|
||||
var/datum/gas_mixture/environment = our_turf.return_air()
|
||||
check_air_dangerlevel(our_turf, environment, environment.temperature)
|
||||
. = TRUE
|
||||
if("mode")
|
||||
mode = text2num(params["mode"])
|
||||
@@ -668,33 +577,36 @@
|
||||
icon_state = "alarm1"
|
||||
return ..()
|
||||
|
||||
/obj/machinery/airalarm/process()
|
||||
/**
|
||||
* main proc for throwing a shitfit if the air isnt right.
|
||||
* goes into warning mode if gas parameters are beyond the tlv warning bounds, goes into hazard mode if gas parameters are beyond tlv hazard bounds
|
||||
*
|
||||
*/
|
||||
/obj/machinery/airalarm/proc/check_air_dangerlevel(turf/location, datum/gas_mixture/environment, exposed_temperature)
|
||||
SIGNAL_HANDLER
|
||||
if((machine_stat & (NOPOWER|BROKEN)) || shorted)
|
||||
return
|
||||
|
||||
var/turf/location = get_turf(src)
|
||||
if(!location)
|
||||
return
|
||||
var/datum/tlv/current_tlv
|
||||
//cache for sanic speed (lists are references anyways)
|
||||
var/list/cached_tlv = TLV
|
||||
|
||||
var/datum/tlv/cur_tlv
|
||||
|
||||
var/datum/gas_mixture/environment = location.return_air()
|
||||
var/list/env_gases = environment.gases
|
||||
var/partial_pressure = R_IDEAL_GAS_EQUATION * environment.temperature / environment.volume
|
||||
var/partial_pressure = R_IDEAL_GAS_EQUATION * exposed_temperature / environment.volume
|
||||
|
||||
cur_tlv = TLV["pressure"]
|
||||
current_tlv = cached_tlv["pressure"]
|
||||
var/environment_pressure = environment.return_pressure()
|
||||
var/pressure_dangerlevel = cur_tlv.get_danger_level(environment_pressure)
|
||||
var/pressure_dangerlevel = current_tlv.get_danger_level(environment_pressure)
|
||||
|
||||
cur_tlv = TLV["temperature"]
|
||||
var/temperature_dangerlevel = cur_tlv.get_danger_level(environment.temperature)
|
||||
current_tlv = cached_tlv["temperature"]
|
||||
var/temperature_dangerlevel = current_tlv.get_danger_level(exposed_temperature)
|
||||
|
||||
var/gas_dangerlevel = 0
|
||||
for(var/gas_id in env_gases)
|
||||
if(!(gas_id in TLV)) // We're not interested in this gas, it seems.
|
||||
if(!(gas_id in cached_tlv)) // We're not interested in this gas, it seems.
|
||||
continue
|
||||
cur_tlv = TLV[gas_id]
|
||||
gas_dangerlevel = max(gas_dangerlevel, cur_tlv.get_danger_level(env_gases[gas_id][MOLES] * partial_pressure))
|
||||
current_tlv = cached_tlv[gas_id]
|
||||
gas_dangerlevel = max(gas_dangerlevel, current_tlv.get_danger_level(env_gases[gas_id][MOLES] * partial_pressure))
|
||||
|
||||
environment.garbage_collect()
|
||||
|
||||
@@ -702,10 +614,10 @@
|
||||
danger_level = max(pressure_dangerlevel, temperature_dangerlevel, gas_dangerlevel)
|
||||
|
||||
if(old_danger_level != danger_level)
|
||||
apply_danger_level()
|
||||
INVOKE_ASYNC(src, .proc/apply_danger_level)
|
||||
if(mode == AALARM_MODE_REPLACEMENT && environment_pressure < ONE_ATMOSPHERE * 0.05)
|
||||
mode = AALARM_MODE_SCRUBBING
|
||||
apply_mode(src)
|
||||
INVOKE_ASYNC(src, .proc/apply_mode, src)
|
||||
|
||||
|
||||
/obj/machinery/airalarm/proc/post_alert(alert_level)
|
||||
@@ -894,6 +806,104 @@
|
||||
new /obj/item/stack/cable_coil(loc, 3)
|
||||
qdel(src)
|
||||
|
||||
/obj/machinery/airalarm/server // No checks here.
|
||||
TLV = list(
|
||||
"pressure" = new/datum/tlv/no_checks,
|
||||
"temperature" = new/datum/tlv/no_checks,
|
||||
/datum/gas/oxygen = new/datum/tlv/no_checks,
|
||||
/datum/gas/nitrogen = new/datum/tlv/no_checks,
|
||||
/datum/gas/carbon_dioxide = new/datum/tlv/no_checks,
|
||||
/datum/gas/miasma = new/datum/tlv/no_checks,
|
||||
/datum/gas/plasma = new/datum/tlv/no_checks,
|
||||
/datum/gas/nitrous_oxide = new/datum/tlv/no_checks,
|
||||
/datum/gas/bz = new/datum/tlv/no_checks,
|
||||
/datum/gas/hypernoblium = new/datum/tlv/no_checks,
|
||||
/datum/gas/water_vapor = new/datum/tlv/no_checks,
|
||||
/datum/gas/tritium = new/datum/tlv/no_checks,
|
||||
/datum/gas/stimulum = new/datum/tlv/no_checks,
|
||||
/datum/gas/nitryl = new/datum/tlv/no_checks,
|
||||
/datum/gas/pluoxium = new/datum/tlv/no_checks,
|
||||
/datum/gas/freon = new/datum/tlv/no_checks,
|
||||
/datum/gas/hydrogen = new/datum/tlv/no_checks,
|
||||
/datum/gas/healium = new/datum/tlv/dangerous,
|
||||
/datum/gas/proto_nitrate = new/datum/tlv/dangerous,
|
||||
/datum/gas/zauker = new/datum/tlv/dangerous,
|
||||
/datum/gas/helium = new/datum/tlv/dangerous,
|
||||
/datum/gas/antinoblium = new/datum/tlv/dangerous,
|
||||
/datum/gas/halon = new/datum/tlv/dangerous,
|
||||
)
|
||||
|
||||
/obj/machinery/airalarm/kitchen_cold_room // Kitchen cold rooms start off at -14°C or 259.15K.
|
||||
TLV = list(
|
||||
"pressure" = new/datum/tlv(ONE_ATMOSPHERE * 0.8, ONE_ATMOSPHERE * 0.9, ONE_ATMOSPHERE * 1.1, ONE_ATMOSPHERE * 1.2), // kPa
|
||||
"temperature" = new/datum/tlv(COLD_ROOM_TEMP-40, COLD_ROOM_TEMP-20, COLD_ROOM_TEMP+20, COLD_ROOM_TEMP+40),
|
||||
/datum/gas/oxygen = new/datum/tlv(16, 19, 135, 140), // Partial pressure, kpa
|
||||
/datum/gas/nitrogen = new/datum/tlv(-1, -1, 1000, 1000),
|
||||
/datum/gas/carbon_dioxide = new/datum/tlv(-1, -1, 5, 10),
|
||||
/datum/gas/miasma = new/datum/tlv/(-1, -1, 2, 5),
|
||||
/datum/gas/plasma = new/datum/tlv/dangerous,
|
||||
/datum/gas/nitrous_oxide = new/datum/tlv/dangerous,
|
||||
/datum/gas/bz = new/datum/tlv/dangerous,
|
||||
/datum/gas/hypernoblium = new/datum/tlv(-1, -1, 1000, 1000), // Hyper-Noblium is inert and nontoxic
|
||||
/datum/gas/water_vapor = new/datum/tlv/dangerous,
|
||||
/datum/gas/tritium = new/datum/tlv/dangerous,
|
||||
/datum/gas/stimulum = new/datum/tlv/dangerous,
|
||||
/datum/gas/nitryl = new/datum/tlv/dangerous,
|
||||
/datum/gas/pluoxium = new/datum/tlv(-1, -1, 1000, 1000), // Unlike oxygen, pluoxium does not fuel plasma/tritium fires
|
||||
/datum/gas/freon = new/datum/tlv/dangerous,
|
||||
/datum/gas/hydrogen = new/datum/tlv/dangerous,
|
||||
/datum/gas/healium = new/datum/tlv/dangerous,
|
||||
/datum/gas/proto_nitrate = new/datum/tlv/dangerous,
|
||||
/datum/gas/zauker = new/datum/tlv/dangerous,
|
||||
/datum/gas/helium = new/datum/tlv/dangerous,
|
||||
/datum/gas/antinoblium = new/datum/tlv/dangerous,
|
||||
/datum/gas/halon = new/datum/tlv/dangerous,
|
||||
)
|
||||
|
||||
/obj/machinery/airalarm/unlocked
|
||||
locked = FALSE
|
||||
|
||||
/obj/machinery/airalarm/engine
|
||||
name = "engine air alarm"
|
||||
locked = FALSE
|
||||
req_access = null
|
||||
req_one_access = list(ACCESS_ATMOSPHERICS, ACCESS_ENGINE)
|
||||
|
||||
/obj/machinery/airalarm/mixingchamber
|
||||
name = "chamber air alarm"
|
||||
locked = FALSE
|
||||
req_access = null
|
||||
req_one_access = list(ACCESS_ATMOSPHERICS, ACCESS_ORDNANCE)
|
||||
|
||||
/obj/machinery/airalarm/all_access
|
||||
name = "all-access air alarm"
|
||||
desc = "This particular atmos control unit appears to have no access restrictions."
|
||||
locked = FALSE
|
||||
req_access = null
|
||||
req_one_access = null
|
||||
|
||||
/obj/machinery/airalarm/syndicate //general syndicate access
|
||||
req_access = list(ACCESS_SYNDICATE)
|
||||
|
||||
/obj/machinery/airalarm/away //general away mission access
|
||||
req_access = list(ACCESS_AWAY_GENERAL)
|
||||
|
||||
/obj/machinery/airalarm/directional/north //Pixel offsets get overwritten on New()
|
||||
dir = SOUTH
|
||||
pixel_y = 24
|
||||
|
||||
/obj/machinery/airalarm/directional/south
|
||||
dir = NORTH
|
||||
pixel_y = -24
|
||||
|
||||
/obj/machinery/airalarm/directional/east
|
||||
dir = WEST
|
||||
pixel_x = 24
|
||||
|
||||
/obj/machinery/airalarm/directional/west
|
||||
dir = EAST
|
||||
pixel_x = -24
|
||||
|
||||
/obj/item/circuit_component/air_alarm
|
||||
display_name = "Air Alarm"
|
||||
desc = "Controls levels of gases and their temperature as well as all vents and scrubbers in the room."
|
||||
@@ -968,10 +978,10 @@
|
||||
return
|
||||
|
||||
var/datum/tlv/settings = connected_alarm.TLV[options_map[current_option]]
|
||||
settings.min2 = min_2
|
||||
settings.min1 = min_1
|
||||
settings.max1 = max_1
|
||||
settings.max2 = max_2
|
||||
settings.hazard_min = min_2
|
||||
settings.warning_min = min_1
|
||||
settings.warning_max = max_1
|
||||
settings.hazard_max = max_2
|
||||
|
||||
#undef AALARM_MODE_SCRUBBING
|
||||
#undef AALARM_MODE_VENTING
|
||||
|
||||
@@ -439,7 +439,7 @@
|
||||
switch(action)
|
||||
if("power")
|
||||
on = !on
|
||||
use_power = on ? ACTIVE_POWER_USE : IDLE_POWER_USE
|
||||
update_use_power(on ? ACTIVE_POWER_USE : IDLE_POWER_USE)
|
||||
investigate_log("was turned [on ? "on" : "off"] by [key_name(usr)]", INVESTIGATE_ATMOS)
|
||||
. = TRUE
|
||||
if("cooling")
|
||||
|
||||
@@ -310,7 +310,7 @@
|
||||
switch(action)
|
||||
if("start_power")
|
||||
connected_core.start_power = !connected_core.start_power
|
||||
connected_core.use_power = connected_core.start_power ? ACTIVE_POWER_USE : IDLE_POWER_USE
|
||||
connected_core.update_use_power(connected_core.start_power ? ACTIVE_POWER_USE : IDLE_POWER_USE)
|
||||
. = TRUE
|
||||
if("start_cooling")
|
||||
connected_core.start_cooling = !connected_core.start_cooling
|
||||
|
||||
@@ -188,7 +188,8 @@
|
||||
if(machine_stat & (NOPOWER|BROKEN))
|
||||
return FALSE
|
||||
if(use_power == ACTIVE_POWER_USE)
|
||||
active_power_usage = ((power_level + 1) * MIN_POWER_USAGE) //Max around 350 KW
|
||||
update_mode_power_usage(ACTIVE_POWER_USE, (power_level + 1) * MIN_POWER_USAGE) //Max around 350 KW
|
||||
|
||||
return TRUE
|
||||
|
||||
///Checks if the gases in the input are the ones needed by the recipe
|
||||
|
||||
@@ -19,7 +19,7 @@
|
||||
|
||||
var/filter_types = list(/datum/gas/carbon_dioxide)
|
||||
var/volume_rate = 200
|
||||
var/widenet = 0 //is this scrubber acting on the 3x3 area around it.
|
||||
var/widenet = FALSE //is this scrubber acting on the 3x3 area around it.
|
||||
var/list/turf/adjacent_turfs = list()
|
||||
|
||||
var/frequency = FREQ_ATMOS_CONTROL
|
||||
@@ -50,22 +50,6 @@
|
||||
adjacent_turfs.Cut()
|
||||
return ..()
|
||||
|
||||
/obj/machinery/atmospherics/components/unary/vent_scrubber/auto_use_power()
|
||||
if(!on || welded || !is_operational || !powered(power_channel))
|
||||
return FALSE
|
||||
|
||||
var/amount = idle_power_usage
|
||||
|
||||
if(scrubbing & SCRUBBING)
|
||||
amount += idle_power_usage * length(filter_types)
|
||||
else //scrubbing == SIPHONING
|
||||
amount = active_power_usage
|
||||
|
||||
if(widenet)
|
||||
amount += amount * (adjacent_turfs.len * (adjacent_turfs.len / 2))
|
||||
use_power(amount, power_channel)
|
||||
return TRUE
|
||||
|
||||
/obj/machinery/atmospherics/components/unary/vent_scrubber/update_icon_nopipes()
|
||||
cut_overlays()
|
||||
if(showpipe)
|
||||
@@ -162,7 +146,7 @@
|
||||
if(air_contents.return_pressure() >= 50 * ONE_ATMOSPHERE)
|
||||
return FALSE
|
||||
|
||||
if(scrubbing & SCRUBBING)
|
||||
if(scrubbing == SCRUBBING)
|
||||
if(length(env_gases & filter_types))
|
||||
var/transfer_moles = min(1, volume_rate / environment.volume) * environment.total_moles()
|
||||
|
||||
@@ -209,19 +193,21 @@
|
||||
if(widenet)
|
||||
check_turfs()
|
||||
|
||||
//we populate a list of turfs with nonatmos-blocked cardinal turfs AND
|
||||
// diagonal turfs that can share atmos with *both* of the cardinal turfs
|
||||
|
||||
///we populate a list of turfs with nonatmos-blocked cardinal turfs AND
|
||||
/// diagonal turfs that can share atmos with *both* of the cardinal turfs
|
||||
/obj/machinery/atmospherics/components/unary/vent_scrubber/proc/check_turfs()
|
||||
adjacent_turfs.Cut()
|
||||
var/turf/T = get_turf(src)
|
||||
if(istype(T))
|
||||
adjacent_turfs = T.GetAtmosAdjacentTurfs(alldir = 1)
|
||||
adjacent_turfs = T.GetAtmosAdjacentTurfs(alldir = TRUE)
|
||||
|
||||
/obj/machinery/atmospherics/components/unary/vent_scrubber/receive_signal(datum/signal/signal)
|
||||
if(!is_operational || !signal.data["tag"] || (signal.data["tag"] != id_tag) || (signal.data["sigtype"]!="command"))
|
||||
return
|
||||
|
||||
var/old_widenet = widenet
|
||||
var/old_scrubbing = scrubbing
|
||||
var/old_filter_length = length(filter_types)
|
||||
|
||||
var/atom/signal_sender = signal.data["user"]
|
||||
|
||||
if("power" in signal.data)
|
||||
@@ -234,7 +220,6 @@
|
||||
if("toggle_widenet" in signal.data)
|
||||
widenet = !widenet
|
||||
|
||||
var/old_scrubbing = scrubbing
|
||||
if("scrubbing" in signal.data)
|
||||
scrubbing = text2num(signal.data["scrubbing"])
|
||||
if("toggle_scrubbing" in signal.data)
|
||||
@@ -260,7 +245,25 @@
|
||||
|
||||
broadcast_status()
|
||||
update_appearance()
|
||||
return
|
||||
|
||||
if(length(filter_types) == old_filter_length && old_scrubbing == scrubbing && old_widenet == widenet)
|
||||
return
|
||||
|
||||
idle_power_usage = initial(idle_power_usage)
|
||||
active_power_usage = initial(idle_power_usage)
|
||||
|
||||
var/new_power_usage = 0
|
||||
if(scrubbing == SCRUBBING)
|
||||
new_power_usage = idle_power_usage + idle_power_usage * length(filter_types)
|
||||
update_use_power(IDLE_POWER_USE)
|
||||
else
|
||||
new_power_usage = active_power_usage
|
||||
update_use_power(ACTIVE_POWER_USE)
|
||||
|
||||
if(widenet)
|
||||
new_power_usage += new_power_usage * (length(adjacent_turfs) * (length(adjacent_turfs) / 2))
|
||||
|
||||
update_mode_power_usage(scrubbing == SCRUBBING ? IDLE_POWER_USE : ACTIVE_POWER_USE, new_power_usage)
|
||||
|
||||
/obj/machinery/atmospherics/components/unary/vent_scrubber/power_change()
|
||||
. = ..()
|
||||
|
||||
@@ -87,15 +87,15 @@
|
||||
var/P = G.return_pressure()
|
||||
switch(power_draw)
|
||||
if(GASMINER_POWER_NONE)
|
||||
active_power_usage = 0
|
||||
update_use_power(ACTIVE_POWER_USE, 0)
|
||||
if(GASMINER_POWER_STATIC)
|
||||
active_power_usage = power_draw_static
|
||||
update_use_power(ACTIVE_POWER_USE, power_draw_static)
|
||||
if(GASMINER_POWER_MOLES)
|
||||
active_power_usage = spawn_mol * power_draw_dynamic_mol_coeff
|
||||
update_use_power(ACTIVE_POWER_USE, spawn_mol * power_draw_dynamic_mol_coeff)
|
||||
if(GASMINER_POWER_KPA)
|
||||
active_power_usage = P * power_draw_dynamic_kpa_coeff
|
||||
update_use_power(ACTIVE_POWER_USE, P * power_draw_dynamic_kpa_coeff)
|
||||
if(GASMINER_POWER_FULLSCALE)
|
||||
active_power_usage = (spawn_mol * power_draw_dynamic_mol_coeff) + (P * power_draw_dynamic_kpa_coeff)
|
||||
update_use_power(ACTIVE_POWER_USE, (spawn_mol * power_draw_dynamic_mol_coeff) + (P * power_draw_dynamic_kpa_coeff))
|
||||
|
||||
/obj/machinery/atmospherics/miner/proc/do_use_power(amount)
|
||||
var/turf/T = get_turf(src)
|
||||
|
||||
@@ -202,7 +202,7 @@
|
||||
if((!anchored && !movable) || !is_operational)
|
||||
on = FALSE
|
||||
update_appearance()
|
||||
use_power = on ? ACTIVE_POWER_USE : IDLE_POWER_USE
|
||||
update_use_power(on ? ACTIVE_POWER_USE : IDLE_POWER_USE)
|
||||
if(!on)
|
||||
return ..()
|
||||
|
||||
|
||||
@@ -216,7 +216,7 @@ GLOBAL_LIST_EMPTY(gateway_destinations)
|
||||
target = null
|
||||
dest.deactivate(src)
|
||||
QDEL_NULL(portal)
|
||||
use_power = IDLE_POWER_USE
|
||||
update_use_power(IDLE_POWER_USE)
|
||||
update_appearance()
|
||||
portal_visuals.reset_visuals()
|
||||
|
||||
@@ -244,7 +244,7 @@ GLOBAL_LIST_EMPTY(gateway_destinations)
|
||||
target.activate(destination)
|
||||
portal_visuals.setup_visuals(target)
|
||||
generate_bumper()
|
||||
use_power = ACTIVE_POWER_USE
|
||||
update_use_power(ACTIVE_POWER_USE)
|
||||
update_appearance()
|
||||
|
||||
/obj/machinery/gateway/proc/Transfer(atom/movable/AM)
|
||||
|
||||
@@ -206,9 +206,9 @@ GLOBAL_LIST_INIT(scan_conditions,init_scan_conditions())
|
||||
/obj/machinery/exoscanner/proc/scan_change()
|
||||
SIGNAL_HANDLER
|
||||
if(GLOB.exoscanner_controller.current_scan)
|
||||
use_power = ACTIVE_POWER_USE
|
||||
update_use_power(ACTIVE_POWER_USE)
|
||||
else
|
||||
use_power = IDLE_POWER_USE
|
||||
update_use_power(IDLE_POWER_USE)
|
||||
update_icon_state()
|
||||
|
||||
/obj/machinery/exoscanner/Destroy()
|
||||
|
||||
@@ -339,10 +339,10 @@
|
||||
/obj/machinery/smartfridge/drying_rack/proc/toggle_drying(forceoff)
|
||||
if(drying || forceoff)
|
||||
drying = FALSE
|
||||
use_power = IDLE_POWER_USE
|
||||
update_use_power(IDLE_POWER_USE)
|
||||
else
|
||||
drying = TRUE
|
||||
use_power = ACTIVE_POWER_USE
|
||||
update_use_power(ACTIVE_POWER_USE)
|
||||
update_appearance()
|
||||
|
||||
/obj/machinery/smartfridge/drying_rack/proc/rack_dry(obj/item/target)
|
||||
|
||||
@@ -203,7 +203,7 @@ and clear when youre done! if you dont i will use :newspaper2: on you
|
||||
|
||||
spawning_simulation = TRUE
|
||||
active = (map_id != offline_program)
|
||||
use_power = active + IDLE_POWER_USE
|
||||
update_use_power(active + IDLE_POWER_USE)
|
||||
program = map_id
|
||||
|
||||
//clear the items from the previous program
|
||||
@@ -326,7 +326,7 @@ and clear when youre done! if you dont i will use :newspaper2: on you
|
||||
derez(item)
|
||||
for(var/obj/effect/holodeck_effect/holo_effect as anything in effects)
|
||||
holo_effect.tick()
|
||||
active_power_usage = 50 + spawned.len * 3 + effects.len * 5
|
||||
update_mode_power_usage(ACTIVE_POWER_USE, 50 + spawned.len * 3 + effects.len * 5)
|
||||
|
||||
/obj/machinery/computer/holodeck/proc/toggle_power(toggleOn = FALSE)
|
||||
if(active == toggleOn)
|
||||
|
||||
@@ -7,7 +7,8 @@
|
||||
pixel_z = 8
|
||||
obj_flags = CAN_BE_HIT | UNIQUE_RENAME
|
||||
circuit = /obj/item/circuitboard/machine/hydroponics
|
||||
idle_power_usage = 0
|
||||
idle_power_usage = 5000
|
||||
use_power = NO_POWER_USE
|
||||
///The amount of water in the tray (max 100)
|
||||
var/waterlevel = 100
|
||||
///The maximum amount of water in the tray
|
||||
@@ -125,6 +126,11 @@
|
||||
else
|
||||
return ..()
|
||||
|
||||
/obj/machinery/hydroponics/power_change()
|
||||
. = ..()
|
||||
if(machine_stat & NOPOWER && self_sustaining)
|
||||
self_sustaining = FALSE
|
||||
|
||||
/obj/machinery/hydroponics/process(delta_time)
|
||||
var/needs_update = 0 // Checks if the icon needs updating so we don't redraw empty trays every time
|
||||
|
||||
@@ -132,8 +138,8 @@
|
||||
myseed.forceMove(src)
|
||||
|
||||
if(!powered() && self_sustaining)
|
||||
visible_message(span_warning("[name]'s auto-grow functionality shuts off!"))
|
||||
idle_power_usage = 0
|
||||
visible_message("<span class='warning'>[name]'s auto-grow functionality shuts off!</span>")
|
||||
update_use_power(NO_POWER_USE)
|
||||
self_sustaining = FALSE
|
||||
update_appearance()
|
||||
|
||||
@@ -767,12 +773,14 @@
|
||||
return
|
||||
if(!powered())
|
||||
to_chat(user, span_warning("[name] has no power."))
|
||||
update_use_power(NO_POWER_USE)
|
||||
return
|
||||
if(!anchored)
|
||||
return
|
||||
self_sustaining = !self_sustaining
|
||||
idle_power_usage = self_sustaining ? 5000 : 0
|
||||
update_use_power(self_sustaining ? IDLE_POWER_USE : NO_POWER_USE)
|
||||
to_chat(user, "<span class='notice'>You [self_sustaining ? "activate" : "deactivated"] [src]'s autogrow function[self_sustaining ? ", maintaining the tray's health while using high amounts of power" : ""].")
|
||||
|
||||
update_appearance()
|
||||
|
||||
/obj/machinery/hydroponics/AltClick(mob/user)
|
||||
@@ -809,7 +817,7 @@
|
||||
desc = initial(desc)
|
||||
TRAY_NAME_UPDATE
|
||||
if(self_sustaining) //No reason to pay for an empty tray.
|
||||
idle_power_usage = 0
|
||||
update_use_power(NO_POWER_USE)
|
||||
self_sustaining = FALSE
|
||||
update_appearance()
|
||||
|
||||
|
||||
@@ -32,6 +32,8 @@
|
||||
/// The APCs power channel is automatically on.
|
||||
#define APC_CHANNEL_AUTO_ON 3
|
||||
|
||||
#define APC_CHANNEL_IS_ON(channel) (channel >= APC_CHANNEL_ON)
|
||||
|
||||
// APC autoset enums:
|
||||
/// The APC turns automated and manual power channels off.
|
||||
#define AUTOSET_FORCE_OFF 0
|
||||
@@ -138,7 +140,7 @@
|
||||
var/environ = APC_CHANNEL_AUTO_ON
|
||||
var/operating = TRUE
|
||||
var/charging = APC_NOT_CHARGING
|
||||
var/chargemode = 1
|
||||
var/chargemode = TRUE
|
||||
var/chargecount = 0
|
||||
var/locked = TRUE
|
||||
var/coverlocked = TRUE
|
||||
@@ -158,6 +160,7 @@
|
||||
var/beenhit = 0 // used for counting how many times it has been hit, used for Aliens at the moment
|
||||
var/mob/living/silicon/ai/occupier = null
|
||||
var/transfer_in_progress = FALSE //Is there an AI being transferred out of us?
|
||||
///buffer state that makes apcs not shut off channels immediately as long as theres some power left, effect visible in apcs only slowly losing power
|
||||
var/longtermpower = 10
|
||||
var/auto_name = FALSE
|
||||
var/failure_timer = 0
|
||||
@@ -1281,9 +1284,10 @@
|
||||
force_update = TRUE
|
||||
return
|
||||
|
||||
lastused_light = area.power_usage[AREA_USAGE_LIGHT] + area.power_usage[AREA_USAGE_STATIC_LIGHT]
|
||||
lastused_equip = area.power_usage[AREA_USAGE_EQUIP] + area.power_usage[AREA_USAGE_STATIC_EQUIP]
|
||||
lastused_environ = area.power_usage[AREA_USAGE_ENVIRON] + area.power_usage[AREA_USAGE_STATIC_ENVIRON]
|
||||
//dont use any power from that channel if we shut that power channel off
|
||||
lastused_light = APC_CHANNEL_IS_ON(lighting) ? area.power_usage[AREA_USAGE_LIGHT] + area.power_usage[AREA_USAGE_STATIC_LIGHT] : 0
|
||||
lastused_equip = APC_CHANNEL_IS_ON(equipment) ? area.power_usage[AREA_USAGE_EQUIP] + area.power_usage[AREA_USAGE_STATIC_EQUIP] : 0
|
||||
lastused_environ = APC_CHANNEL_IS_ON(environ) ? area.power_usage[AREA_USAGE_ENVIRON] + area.power_usage[AREA_USAGE_STATIC_ENVIRON] : 0
|
||||
area.clear_usage()
|
||||
|
||||
lastused_total = lastused_light + lastused_equip + lastused_environ
|
||||
@@ -1447,17 +1451,18 @@
|
||||
* - [AUTOSET_OFF]: The APC turns automatic channels off.
|
||||
*/
|
||||
/obj/machinery/power/apc/proc/autoset(val, on)
|
||||
if(on == AUTOSET_FORCE_OFF)
|
||||
if(val == APC_CHANNEL_ON) // if on, return off
|
||||
return APC_CHANNEL_OFF
|
||||
else if(val == APC_CHANNEL_AUTO_ON) // if auto-on, return auto-off
|
||||
return APC_CHANNEL_AUTO_OFF
|
||||
else if(on == AUTOSET_ON)
|
||||
if(val == APC_CHANNEL_AUTO_OFF) // if auto-off, return auto-on
|
||||
return APC_CHANNEL_AUTO_ON
|
||||
else if(on == AUTOSET_OFF)
|
||||
if(val == APC_CHANNEL_AUTO_ON) // if auto-on, return auto-off
|
||||
return APC_CHANNEL_AUTO_OFF
|
||||
switch(on)
|
||||
if(AUTOSET_FORCE_OFF)
|
||||
if(val == APC_CHANNEL_ON) // if on, return off
|
||||
return APC_CHANNEL_OFF
|
||||
else if(val == APC_CHANNEL_AUTO_ON) // if auto-on, return auto-off
|
||||
return APC_CHANNEL_AUTO_OFF
|
||||
if(AUTOSET_ON)
|
||||
if(val == APC_CHANNEL_AUTO_OFF) // if auto-off, return auto-on
|
||||
return APC_CHANNEL_AUTO_ON
|
||||
if(AUTOSET_OFF)
|
||||
if(val == APC_CHANNEL_AUTO_ON) // if auto-on, return auto-off
|
||||
return APC_CHANNEL_AUTO_OFF
|
||||
return val
|
||||
|
||||
/**
|
||||
|
||||
@@ -294,7 +294,7 @@ GLOBAL_LIST_EMPTY(gravity_generators) // We will keep track of this by adding ne
|
||||
/obj/machinery/gravity_generator/main/proc/set_state(new_state)
|
||||
charging_state = POWER_IDLE
|
||||
on = new_state
|
||||
use_power = on ? ACTIVE_POWER_USE : IDLE_POWER_USE
|
||||
update_use_power(on ? ACTIVE_POWER_USE : IDLE_POWER_USE)
|
||||
// Sound the alert if gravity was just enabled or disabled.
|
||||
var/alert = FALSE
|
||||
if(SSticker.IsRoundInProgress())
|
||||
|
||||
@@ -39,10 +39,10 @@
|
||||
|
||||
/obj/machinery/computer/monitor/process()
|
||||
if(!get_powernet())
|
||||
use_power = IDLE_POWER_USE
|
||||
update_use_power(IDLE_POWER_USE)
|
||||
search()
|
||||
else
|
||||
use_power = ACTIVE_POWER_USE
|
||||
update_use_power(ACTIVE_POWER_USE)
|
||||
record()
|
||||
|
||||
/obj/machinery/computer/monitor/proc/search() //keep in sync with /datum/computer_file/program/power_monitor's version
|
||||
|
||||
@@ -79,7 +79,7 @@
|
||||
|
||||
// returns true if the area has power on given channel (or doesn't require power).
|
||||
// defaults to power_channel
|
||||
/obj/machinery/proc/powered(chan = -1) // defaults to power_channel
|
||||
/obj/machinery/proc/powered(chan = power_channel)
|
||||
if(!loc)
|
||||
return FALSE
|
||||
if(!use_power)
|
||||
@@ -88,18 +88,13 @@
|
||||
var/area/A = get_area(src) // make sure it's in an area
|
||||
if(!A)
|
||||
return FALSE // if not, then not powered
|
||||
if(chan == -1)
|
||||
chan = power_channel
|
||||
|
||||
return A.powered(chan) // return power status of the area
|
||||
|
||||
// increment the power usage stats for an area
|
||||
/obj/machinery/proc/use_power(amount, chan = -1) // defaults to power_channel
|
||||
/obj/machinery/proc/use_power(amount, chan = power_channel)
|
||||
var/area/A = get_area(src) // make sure it's in an area
|
||||
if(!A)
|
||||
return
|
||||
if(chan == -1)
|
||||
chan = power_channel
|
||||
A.use_power(amount, chan)
|
||||
A?.use_power(amount, chan)
|
||||
|
||||
/**
|
||||
* An alternative to 'use_power', this proc directly costs the APC in direct charge, as opposed to being calculated periodically.
|
||||
@@ -154,9 +149,7 @@
|
||||
|
||||
/obj/machinery/proc/addStaticPower(value, powerchannel)
|
||||
var/area/A = get_area(src)
|
||||
if(!A)
|
||||
return
|
||||
A.addStaticPower(value, powerchannel)
|
||||
A?.addStaticPower(value, powerchannel)
|
||||
|
||||
/obj/machinery/proc/removeStaticPower(value, powerchannel)
|
||||
addStaticPower(-value, powerchannel)
|
||||
|
||||
@@ -80,7 +80,7 @@
|
||||
//see if there's a surplus of power remaining in the powernet and stores unused power in the SMES
|
||||
netexcess = avail - load
|
||||
|
||||
if(netexcess > 100 && nodes?.len) // if there was excess power last cycle
|
||||
if(netexcess > 100 && length(nodes)) // if there was excess power last cycle
|
||||
for(var/obj/machinery/power/smes/S in nodes) // find the SMESes in the network
|
||||
S.restore() // and restore some of the power that was used
|
||||
|
||||
|
||||
@@ -69,7 +69,7 @@
|
||||
toggle_power()
|
||||
user.visible_message(span_notice("[user.name] turns the [src.name] [active? "on":"off"]."), \
|
||||
span_notice("You turn the [src.name] [active? "on":"off"]."))
|
||||
var/datum/gas_mixture/tank_mix = loaded_tank.return_air()
|
||||
var/datum/gas_mixture/tank_mix = loaded_tank?.return_air()
|
||||
var/fuel
|
||||
if(loaded_tank)
|
||||
fuel = tank_mix.gases[/datum/gas/plasma]
|
||||
|
||||
@@ -67,12 +67,12 @@
|
||||
/obj/machinery/power/emitter/ctf
|
||||
name = "Energy Cannon"
|
||||
active = TRUE
|
||||
active_power_usage = FALSE
|
||||
idle_power_usage = FALSE
|
||||
active_power_usage = 0
|
||||
idle_power_usage = 0
|
||||
locked = TRUE
|
||||
req_access_txt = "100"
|
||||
welded = TRUE
|
||||
use_power = FALSE
|
||||
use_power = NO_POWER_USE
|
||||
|
||||
/obj/machinery/power/emitter/Initialize()
|
||||
. = ..()
|
||||
@@ -110,7 +110,7 @@
|
||||
fire_delay = fire_shoot_delay
|
||||
for(var/obj/item/stock_parts/manipulator/manipulator in component_parts)
|
||||
power_usage -= 50 * manipulator.rating
|
||||
active_power_usage = power_usage
|
||||
update_mode_power_usage(ACTIVE_POWER_USE, power_usage)
|
||||
|
||||
/obj/machinery/power/emitter/examine(mob/user)
|
||||
. = ..()
|
||||
|
||||
@@ -9,7 +9,7 @@
|
||||
icon_state = "mixer0"
|
||||
icon_keyboard = null
|
||||
base_icon_state = "mixer"
|
||||
use_power = TRUE
|
||||
use_power = IDLE_POWER_USE
|
||||
idle_power_usage = 20
|
||||
resistance_flags = ACID_PROOF
|
||||
circuit = /obj/item/circuitboard/computer/pandemic
|
||||
|
||||
@@ -188,7 +188,7 @@
|
||||
return
|
||||
calcsuccess()
|
||||
use_power(MACHINE_OPERATION * power_saver) //This thing should eat your APC battery if you're not careful.
|
||||
use_power = IDLE_POWER_USE //Machine shuts off after use to prevent spam and look better visually.
|
||||
update_use_power(IDLE_POWER_USE) //Machine shuts off after use to prevent spam and look better visually.
|
||||
update_appearance()
|
||||
if("amount")
|
||||
var/input = text2num(params["amount"])
|
||||
@@ -196,9 +196,9 @@
|
||||
banking_amount = input
|
||||
if("toggle_power")
|
||||
if(use_power == ACTIVE_POWER_USE)
|
||||
use_power = IDLE_POWER_USE
|
||||
update_use_power(IDLE_POWER_USE)
|
||||
else
|
||||
use_power = ACTIVE_POWER_USE
|
||||
update_use_power(ACTIVE_POWER_USE)
|
||||
update_appearance()
|
||||
if("account_reset")
|
||||
if(use_power == IDLE_POWER_USE)
|
||||
|
||||
@@ -229,7 +229,7 @@
|
||||
name = "luxury shuttle ticket field"
|
||||
density = FALSE //allows shuttle airlocks to close, nothing but an approved passenger gets past CanPass
|
||||
locked = TRUE
|
||||
use_power = FALSE
|
||||
use_power = NO_POWER_USE
|
||||
resistance_flags = INDESTRUCTIBLE | LAVA_PROOF | FIRE_PROOF | UNACIDABLE | ACID_PROOF
|
||||
var/threshold = 500
|
||||
var/static/list/approved_passengers = list()
|
||||
|
||||
@@ -92,7 +92,7 @@
|
||||
base_icon_state = "sat"
|
||||
anchored = FALSE
|
||||
density = TRUE
|
||||
use_power = FALSE
|
||||
use_power = NO_POWER_USE
|
||||
var/mode = "NTPROBEV0.8"
|
||||
var/active = FALSE
|
||||
var/static/gid = 0
|
||||
|
||||
@@ -185,7 +185,7 @@
|
||||
*/
|
||||
/obj/machinery/mecha_part_fabricator/proc/on_start_printing()
|
||||
add_overlay("fab-active")
|
||||
use_power = ACTIVE_POWER_USE
|
||||
update_use_power(ACTIVE_POWER_USE)
|
||||
|
||||
/**
|
||||
* Intended to be called when the exofab has stopped working and is no longer printing items.
|
||||
@@ -194,7 +194,7 @@
|
||||
*/
|
||||
/obj/machinery/mecha_part_fabricator/proc/on_finish_printing()
|
||||
cut_overlay("fab-active")
|
||||
use_power = IDLE_POWER_USE
|
||||
update_use_power(IDLE_POWER_USE)
|
||||
desc = initial(desc)
|
||||
process_queue = FALSE
|
||||
|
||||
|
||||
@@ -255,10 +255,10 @@ const AirAlarmControlThresholds = (props, context) => {
|
||||
<thead>
|
||||
<tr>
|
||||
<td />
|
||||
<td className="color-bad">min2</td>
|
||||
<td className="color-average">min1</td>
|
||||
<td className="color-average">max1</td>
|
||||
<td className="color-bad">max2</td>
|
||||
<td className="color-bad">hazard_min</td>
|
||||
<td className="color-average">warning_min</td>
|
||||
<td className="color-average">warning_max</td>
|
||||
<td className="color-bad">hazard_max</td>
|
||||
</tr>
|
||||
</thead>
|
||||
<tbody>
|
||||
|
||||
Reference in New Issue