tgui: Temperature Gate (#53632)

* new device, temperature gate

* added necessary examine on device

* better description(?)
This commit is contained in:
Ghilker
2020-09-13 00:37:40 +03:00
committed by GitHub
parent 32193e45d0
commit fb7b23cf4d
9 changed files with 179 additions and 3 deletions
+1
View File
@@ -34,6 +34,7 @@ GLOBAL_LIST_INIT(atmos_pipe_recipes, list(
new /datum/pipe_info/pipe("Manual Valve", /obj/machinery/atmospherics/components/binary/valve, TRUE),
new /datum/pipe_info/pipe("Digital Valve", /obj/machinery/atmospherics/components/binary/valve/digital, TRUE),
new /datum/pipe_info/pipe("Pressure Valve", /obj/machinery/atmospherics/components/binary/pressure_valve, TRUE),
new /datum/pipe_info/pipe("Temperature Gate", /obj/machinery/atmospherics/components/binary/temperature_gate, TRUE),
new /datum/pipe_info/pipe("Temperature Pump", /obj/machinery/atmospherics/components/binary/temperature_pump, TRUE),
new /datum/pipe_info/meter("Meter"),
),
@@ -0,0 +1,127 @@
/obj/machinery/atmospherics/components/binary/temperature_gate
icon_state = "tgate_map-3"
name = "temperature gate"
desc = "An activable gate that compares the input temperature with the interface set temperature to check if the gas can flow or not."
can_unwrench = TRUE
shift_underlay_only = FALSE
construction_type = /obj/item/pipe/directional
pipe_state = "tgate"
///If the temperature of the mix before the gate is lower than this, the gas will flow (if inverted, if the temperature of the mix before the gate is higher than this)
var/target_temperature = T0C
///Minimum allowed temperature
var/minimum_temperature = TCMB
///Maximum allowed temperature to be set
var/max_temperature = 4500
///Check if the sensor should let gas pass if temperature in the mix is less/higher than the target one
var/inverted = FALSE
///Check if the gas is moving from one pipenet to the other
var/is_gas_flowing = FALSE
/obj/machinery/atmospherics/components/binary/temperature_gate/CtrlClick(mob/user)
if(can_interact(user))
on = !on
investigate_log("was turned [on ? "on" : "off"] by [key_name(user)]", INVESTIGATE_ATMOS)
update_icon()
return ..()
/obj/machinery/atmospherics/components/binary/temperature_gate/AltClick(mob/user)
if(can_interact(user))
target_temperature = max_temperature
investigate_log("was set to [target_temperature] K by [key_name(user)]", INVESTIGATE_ATMOS)
to_chat(user, "<span class='notice'>You set the target temperature on [src] to [target_temperature] K.</span>")
update_icon()
return ..()
/obj/machinery/atmospherics/components/binary/temperature_gate/examine(mob/user)
. = ..()
. += "This device will let gas flow if the temperature of the gas in the input is [inverted ? "higher" : "lower"] than the temperature set in the interface."
if(inverted)
. += "The device settings can be restored if a multitool is used on it."
else
. += "The sensor's settings can be changed by using a multitool on the device."
/obj/machinery/atmospherics/components/binary/temperature_gate/update_icon_nopipes()
if(on && is_operational && is_gas_flowing)
icon_state = "tgate_flow-[set_overlay_offset(piping_layer)]"
else if(on && is_operational && !is_gas_flowing)
icon_state = "tgate_on-[set_overlay_offset(piping_layer)]"
else
icon_state = "tgate_off-[set_overlay_offset(piping_layer)]"
/obj/machinery/atmospherics/components/binary/temperature_gate/process_atmos()
if(!on || !is_operational)
return
var/datum/gas_mixture/air1 = airs[1]
var/datum/gas_mixture/air2 = airs[2]
if(!inverted)
if(air1.temperature < target_temperature)
if(air1.release_gas_to(air2, air1.return_pressure()))
update_parents()
is_gas_flowing = TRUE
else
is_gas_flowing = FALSE
else
if(air1.temperature > target_temperature)
if(air1.release_gas_to(air2, air1.return_pressure()))
update_parents()
is_gas_flowing = TRUE
else
is_gas_flowing = FALSE
update_icon_nopipes()
/obj/machinery/atmospherics/components/binary/temperature_gate/ui_interact(mob/user, datum/tgui/ui)
ui = SStgui.try_update_ui(user, src, ui)
if(!ui)
ui = new(user, src, "AtmosTempGate", name)
ui.open()
/obj/machinery/atmospherics/components/binary/temperature_gate/ui_data()
var/data = list()
data["on"] = on
data["temperature"] = round(target_temperature)
data["max_temperature"] = round(max_temperature*100)
return data
/obj/machinery/atmospherics/components/binary/temperature_gate/ui_act(action, params)
if(..())
return
switch(action)
if("power")
on = !on
investigate_log("was turned [on ? "on" : "off"] by [key_name(usr)]", INVESTIGATE_ATMOS)
. = TRUE
if("temperature")
var/temperature = params["temperature"]
if(temperature == "max")
temperature = max_temperature
. = TRUE
else if(text2num(temperature) != null)
temperature = text2num(temperature)
. = TRUE
if(.)
target_temperature = clamp(minimum_temperature, temperature, max_temperature)
investigate_log("was set to [target_temperature] K by [key_name(usr)]", INVESTIGATE_ATMOS)
update_icon()
/obj/machinery/atmospherics/components/binary/temperature_gate/can_unwrench(mob/user)
. = ..()
if(. && on && is_operational)
to_chat(user, "<span class='warning'>You cannot unwrench [src], turn it off first!</span>")
return FALSE
/obj/machinery/atmospherics/components/binary/temperature_gate/multitool_act(mob/living/user, obj/item/multitool/I)
. = ..()
if (istype(I))
inverted = !inverted
if(inverted)
to_chat(user, "<span class='notice'>You set the [src]'s sensors to release gases when the temperature is higher than the setted one.</span>")
else
to_chat(user, "<span class='notice'>You set the [src]'s sensors to the default settings.</span>")
return TRUE
Binary file not shown.

Before

Width:  |  Height:  |  Size: 67 KiB

After

Width:  |  Height:  |  Size: 76 KiB

Binary file not shown.

Before

Width:  |  Height:  |  Size: 25 KiB

After

Width:  |  Height:  |  Size: 26 KiB

+1
View File
@@ -1608,6 +1608,7 @@
#include "code\modules\atmospherics\machinery\components\binary_devices\passive_gate.dm"
#include "code\modules\atmospherics\machinery\components\binary_devices\pressure_valve.dm"
#include "code\modules\atmospherics\machinery\components\binary_devices\pump.dm"
#include "code\modules\atmospherics\machinery\components\binary_devices\temperature_gate.dm"
#include "code\modules\atmospherics\machinery\components\binary_devices\temperature_pump.dm"
#include "code\modules\atmospherics\machinery\components\binary_devices\valve.dm"
#include "code\modules\atmospherics\machinery\components\binary_devices\volume_pump.dm"
@@ -0,0 +1,47 @@
import { useBackend } from '../backend';
import { Button, LabeledList, NumberInput, Section } from '../components';
import { Window } from '../layouts';
export const AtmosTempGate = (props, context) => {
const { act, data } = useBackend(context);
return (
<Window
width={335}
height={115}>
<Window.Content>
<Section>
<LabeledList>
<LabeledList.Item label="Power">
<Button
icon={data.on ? 'power-off' : 'times'}
content={data.on ? 'On' : 'Off'}
selected={data.on}
onClick={() => act('power')} />
</LabeledList.Item>
<LabeledList.Item label="Heat settings">
<NumberInput
animated
value={parseFloat(data.temperature)}
unit="K"
width="75px"
minValue={3}
maxValue={4500}
step={1}
onChange={(e, value) => act('temperature', {
temperature: value,
})} />
<Button
ml={1}
icon="plus"
content="Max"
disabled={data.temperature === data.max_temperature}
onClick={() => act('temperature', {
temperature: 'max',
})} />
</LabeledList.Item>
</LabeledList>
</Section>
</Window.Content>
</Window>
);
};
File diff suppressed because one or more lines are too long
File diff suppressed because one or more lines are too long
File diff suppressed because one or more lines are too long