Fix for fire alarms in Mining and Research outpost so they actually will change status depending on the alert level of the station.

This commit is contained in:
DJSnapshot
2013-11-07 16:02:57 -08:00
parent 3aa8d088bd
commit 7c59c41b13
2 changed files with 5 additions and 5 deletions

View File

@@ -1511,7 +1511,7 @@ FIRE ALARM
pixel_x = (dir & 3)? 0 : (dir == 4 ? -24 : 24)
pixel_y = (dir & 3)? (dir ==1 ? -24 : 24) : 0
if(z == 1)
if(z == 1 || z == 5)
if(security_level)
src.overlays += image('icons/obj/monitors.dmi', "overlay_[get_security_level()]")
else

View File

@@ -25,7 +25,7 @@
world << "<font color='red'>[config.alert_desc_green]</font>"
security_level = SEC_LEVEL_GREEN
for(var/obj/machinery/firealarm/FA in machines)
if(FA.z == 1)
if(FA.z == 1 || FA.z == 5)
FA.overlays = list()
FA.overlays += image('icons/obj/monitors.dmi', "overlay_green")
if(SEC_LEVEL_BLUE)
@@ -37,7 +37,7 @@
world << "<font color='red'>[config.alert_desc_blue_downto]</font>"
security_level = SEC_LEVEL_BLUE
for(var/obj/machinery/firealarm/FA in machines)
if(FA.z == 1)
if(FA.z == 1 || FA.z == 5)
FA.overlays = list()
FA.overlays += image('icons/obj/monitors.dmi', "overlay_blue")
if(SEC_LEVEL_RED)
@@ -55,7 +55,7 @@
CC.post_status("alert", "redalert")*/
for(var/obj/machinery/firealarm/FA in machines)
if(FA.z == 1)
if(FA.z == 1 || FA.z == 5)
FA.overlays = list()
FA.overlays += image('icons/obj/monitors.dmi', "overlay_red")
@@ -64,7 +64,7 @@
world << "<font color='red'>[config.alert_desc_delta]</font>"
security_level = SEC_LEVEL_DELTA
for(var/obj/machinery/firealarm/FA in machines)
if(FA.z == 1)
if(FA.z == 1 || FA.z == 5)
FA.overlays = list()
FA.overlays += image('icons/obj/monitors.dmi', "overlay_delta")
else