- Re-implements Destroy() for SMES units. This time moves relevant (de)construction code all the way up to obj/machinery/. This should fix any potential GC issues with deconstruction of component-based machines.
- Implements Destroy() for breaker boxes.
- Fixes SMES units lacking disconnect_terminal(), causing GC errors.
Merges the two meteor events into one, and now takes severity into consideration instead.
Including the basic meteors there are also new types ranging from flaming to radioactive which may drop appropriate types of ore.
Created a global list to track base turfs for explosions/shuttle moves.
Remaps the asteroid to be a moonlet. Tidies up some references to 'asteroid', removes moonbase from the accessible z level list.
Affects the Brig, Virology, Xenobiology or all three.
Adds warning messages to Engineering request consoles and AI.
Prevents doors from bolting open if unpowered
Reduces light overload frequency.
- Fixes APC runtime. I am an idiot. I know.
- Fixes potentional power issue with AI powersupply object, caused by AI having more than one powersupply. This sometimes caused AI to use 100kW instead of 50kW
- Fixes#9543
- Removes ugly floodlight/proc/updateicon() and replaces it with proper floodlight/update_icon() which is standard on all objects/items. Does the same refactor for power cells and adjusts the proc call in relevant files (hence the amount of 1-line changes in various files)
- Makes floodlights properly use CELLRATE. Their load is 200 watts. Cell adjusted accordingly, it starts with 1k cell, which is enough for ~40 minutes (roughly)
- Floodlights with almost discharged cell (less than 10%) ocassionally "flicker", dimming for few seconds. This serves as indicator that the power cell is running low.
- Floodlight luminosity adjusted. They now shine slightly more, espicially closer to the floodlight.
- Fixes#9536
- Area now has APC variable, instead of list. APC construction, etc. should have checks to allow one APC per area only, so situations with multi-APC areas are unlikely, unless adminbus occurs. Either way, with or without this commit, one of the APCs would be unoperational (no load)
- get_apc() no longer uses very laggy locate() in contents of area. In situations where get_apc() is called repeately this brings massive increase in performance (from 0.120 to 0.000, depending on area size and amount of things in contents of that area) as it now only returns the apc variable.
Now instead calls the proper round-end proc when finishing the round, allowing admins to interrupt restart if desired.
None of the current end game variants currently use over/underlays, they are now content with coloring space.
On endgame start, the entire world is now updated in a spawn() instead, reducing crippling lag.
Adds support to designate APCs are critical, these are not drained during world end events.
Fixes a couple of potential runtime errors if no escape points have bee mapped in.
People in wheelchairs and mechas can now enter the world end rift.
Cult walls no longer cultify over and over, indefinitely.
Attempted to limit regular surgery to non-robotic limbs and added surgical steps for robotic limbs.
Readded checks for smoking reagent transfer.
Fixes, oversights, tweaks with IPC.
Added some reagent bypassing for NO_BLOOD and some checks to various affect_touch() calls for NO_SCAN/IPC.
Added prosthetic-scanning functionality to cyborg analyzer.
Added prosthetic analysis to the robot analyzer.
Allowed people with internal cells to charge in robot chargers (IPCs).
Moved some organ code around, added icons and limbs for IPC, added IPC limb manufacturer.
Reimplementing checks in place of IS_SYNTHETIC.
Rebalancing EMP a bit for IPC.
- Makes telecommunications solars actually work. They are connected into ring-shaped cable running around whole telecomms, powering single SMES unit which in turn powers the satellite itself.
- Installed solars have maximal combined output of 240kW. Real output fluctuates between 120kW and 160kW depending on star orientation.
- Fractal generator and relevant breaker removed. RCON control is still possible, by adjusting SMES settings.