mirror of
https://github.com/ParadiseSS13/Paradise.git
synced 2026-08-29 06:57:42 +01:00
Fixes incorrect units in Radiocarbon Spectrometer's GUI.
1 GHz = 1 000 MHz = 1 000 000 kHz Conflicts: nano/templates/geoscanner.tmpl
This commit is contained in:
@@ -6,10 +6,10 @@ Used In File(s): \code\modules\research\xenoarchaeology\machinery\geosample_scan
|
||||
<h3>Machine Status</h3>
|
||||
<div class="item">
|
||||
<div class="itemContent" style="width: 20%;">
|
||||
{{:helper.link(data.scanning ? 'Halt Scan' : 'Begin Scan', 'signal-diag', {'scanItem' : 1}, null)}}
|
||||
{{:~link(scanning ? 'Halt Scan' : 'Begin Scan', 'signal-diag', {'scanItem' : 1}, null)}}
|
||||
</div>
|
||||
<div class="itemContent" style="width: 20%;">
|
||||
{{:helper.link('Eject item', 'eject', {'ejectItem' : 1}, (data.scanned_item && !data.scanning) ? null : 'disabled')}}
|
||||
{{:~link('Eject item', 'eject', {'ejectItem' : 1}, (scanned_item && !scanning) ? null : 'disabled')}}
|
||||
</div>
|
||||
</div>
|
||||
|
||||
@@ -17,8 +17,8 @@ Used In File(s): \code\modules\research\xenoarchaeology\machinery\geosample_scan
|
||||
<div class="line">
|
||||
<div class="statusLabel">Item:</div>
|
||||
<div class="statusValue">
|
||||
{{if data.scanned_item}}
|
||||
<span class="good">{{:data.scanned_item}}</span>
|
||||
{{if scanned_item}}
|
||||
<span class="good">{{:scanned_item}}</span>
|
||||
{{else}}
|
||||
<span class="bad">No item inserted</span>
|
||||
{{/if}}
|
||||
@@ -27,8 +27,8 @@ Used In File(s): \code\modules\research\xenoarchaeology\machinery\geosample_scan
|
||||
<div class="line">
|
||||
<div class="statusLabel">Heuristic analysis:</div>
|
||||
<div class="statusValue">
|
||||
{{if data.scanned_item_desc}}
|
||||
<span class="average">{{:data.scanned_item_desc}}</span>
|
||||
{{if scanned_item_desc}}
|
||||
<span class="average">{{:scanned_item_desc}}</span>
|
||||
{{/if}}
|
||||
</div>
|
||||
</div>
|
||||
@@ -38,11 +38,11 @@ Used In File(s): \code\modules\research\xenoarchaeology\machinery\geosample_scan
|
||||
<div class="item">
|
||||
<div class="itemLabel" style="width: 21%;">Scan progress:</div>
|
||||
<div class="itemContent" style="width: 35%;">
|
||||
{{:helper.displayBar(data.scan_progress, 0, 100, 'good')}}
|
||||
{{:data.scan_progress}} %
|
||||
{{:~displayBar(scan_progress, 0, 100, 'good')}}
|
||||
{{:scan_progress}} %
|
||||
</div>
|
||||
<div class="itemContent" style="width: 44%;">
|
||||
{{if data.scan_progress >= 100}}
|
||||
{{if scan_progress >= 100}}
|
||||
<span class="notice" style="width: 100%;">Scan completed successfully.</span>
|
||||
{{/if}}
|
||||
</div>
|
||||
@@ -50,11 +50,11 @@ Used In File(s): \code\modules\research\xenoarchaeology\machinery\geosample_scan
|
||||
<div class="item">
|
||||
<div class="itemLabel" style="width: 21%;">Vacuum seal integrity:</div>
|
||||
<div class="itemContent" style="width: 35%;">
|
||||
{{:helper.displayBar(data.scanner_seal_integrity, 0, 100, ((data.scanner_seal_integrity < 66) ? ((data.scanner_seal_integrity < 33) ? 'bad' : 'average') : 'good'))}}
|
||||
{{:data.scanner_seal_integrity}} %
|
||||
{{:~displayBar(scanner_seal_integrity, 0, 100, (scanner_seal_integrity < 66 ? (scanner_seal_integrity < 33 ? 'bad' : 'average') : 'good'))}}
|
||||
{{:scanner_seal_integrity}} %
|
||||
</div>
|
||||
<div class="itemContent" style="width: 44%;">
|
||||
{{if data.scanner_seal_integrity < 25}}
|
||||
{{if scanner_seal_integrity < 25}}
|
||||
<span class="notice">Warning! Vacuum seal breach will result in scan failure!</span>
|
||||
{{/if}}
|
||||
</div>
|
||||
@@ -64,11 +64,11 @@ Used In File(s): \code\modules\research\xenoarchaeology\machinery\geosample_scan
|
||||
<div class="item">
|
||||
<div class="itemLabel" style="width: 21%;">MASER Efficiency:</div>
|
||||
<div class="itemContent" style="width: 35%;">
|
||||
{{:helper.displayBar(data.maser_efficiency, 1, 100, ((data.maser_efficiency < 66) ? ((data.maser_efficiency) < 33 ? 'bad' : 'average') : 'good'))}}
|
||||
{{:data.maser_efficiency}} %
|
||||
{{:~displayBar(maser_efficiency, 1, 100, (maser_efficiency < 66 ? (maser_efficiency < 33 ? 'bad' : 'average') : 'good'))}}
|
||||
{{:maser_efficiency}} %
|
||||
</div>
|
||||
<div class="itemContent" style="width: 44%;">
|
||||
{{if data.maser_efficiency < 50}}
|
||||
{{if maser_efficiency < 50}}
|
||||
<span class="notice">Match wavelengths to progress the scan.</span>
|
||||
{{/if}}
|
||||
</div>
|
||||
@@ -76,25 +76,25 @@ Used In File(s): \code\modules\research\xenoarchaeology\machinery\geosample_scan
|
||||
<div class="item">
|
||||
<div class="itemLabel" style="width: 21%;">Optimal Wavelength:</div>
|
||||
<div class="itemContent" style="width: 35%;">
|
||||
{{:helper.displayBar(data.optimal_wavelength, 1, 10000, 'good')}}
|
||||
{{:data.optimal_wavelength}} MHz
|
||||
{{:~displayBar(optimal_wavelength, 1, 10000, 'good')}}
|
||||
{{:optimal_wavelength}} MHz
|
||||
</div>
|
||||
</div>
|
||||
<div class="item">
|
||||
<div class="itemLabel" style="width: 21%;">Current Wavelength:</div>
|
||||
<div class="itemContent" style="width: 35%;">
|
||||
{{:helper.displayBar(data.maser_wavelength, 1, 10000, 'good')}}
|
||||
{{:data.maser_wavelength}} MHz
|
||||
{{:~displayBar(maser_wavelength, 1, 10000, 'good')}}
|
||||
{{:maser_wavelength}} MHz
|
||||
</div>
|
||||
<div class="itemContent" style="text-align:left; width: 22%;">
|
||||
{{:helper.link('-2 KHz', null, {'maserWavelength' : -2}, null)}}
|
||||
{{:helper.link('-1 KHz', null, {'maserWavelength' : -1}, null)}}
|
||||
{{:helper.link('-0.5 KHz', null, {'maserWavelength' : -0.5}, null)}}
|
||||
{{:~link('-2 GHz', null, {'maserWavelength' : -2}, null)}}
|
||||
{{:~link('-1 GHz', null, {'maserWavelength' : -1}, null)}}
|
||||
{{:~link('-0.5 GHz', null, {'maserWavelength' : -0.5}, null)}}
|
||||
</div>
|
||||
<div class="itemContent" style="text-align:right; width: 22%;">
|
||||
{{:helper.link('+0.5 KHz', null, {'maserWavelength' : 0.5}, null)}}
|
||||
{{:helper.link('+1 KHz', null, {'maserWavelength' : 1}, null)}}
|
||||
{{:helper.link('+2 KHz', null, {'maserWavelength' : 2}, null)}}
|
||||
{{:~link('+0.5 GHz', null, {'maserWavelength' : 0.5}, null)}}
|
||||
{{:~link('+1 GHz', null, {'maserWavelength' : 1}, null)}}
|
||||
{{:~link('+2 GHz', null, {'maserWavelength' : 2}, null)}}
|
||||
</div>
|
||||
</div>
|
||||
|
||||
@@ -102,18 +102,18 @@ Used In File(s): \code\modules\research\xenoarchaeology\machinery\geosample_scan
|
||||
<div class="item">
|
||||
<div class="itemLabel" style="width: 21%;">Centrifuge speed:</div>
|
||||
<div class="itemContent" style="width: 35%;">
|
||||
{{:helper.displayBar(data.scanner_rpm, 0, 1000, 'good')}}
|
||||
{{:data.scanner_rpm}} RPM
|
||||
{{:~displayBar(scanner_rpm, 0, 1000, 'good')}}
|
||||
{{:scanner_rpm}} RPM
|
||||
</div>
|
||||
</div>
|
||||
<div class="item">
|
||||
<div class="itemLabel" style="width: 21%;">Internal temperature:</div>
|
||||
<div class="itemContent" style="width: 35%;">
|
||||
{{:helper.displayBar(data.scanner_temperature, 0, 1273, (data.scanner_temperature > 250 ? (data.scanner_temperature > 1000 ? 'bad' : 'average') : 'good')))}}
|
||||
{{:data.scanner_temperature}} K
|
||||
{{:~displayBar(scanner_temperature, 0, 1273, (scanner_temperature > 250 ? (scanner_temperature > 1000 ? 'bad' : 'average') : 'good')))}}
|
||||
{{:scanner_temperature}} K
|
||||
</div>
|
||||
<div class="itemContent" style="width: 44%;">
|
||||
{{if data.scanner_temperature > 1000}}
|
||||
{{if scanner_temperature > 1000}}
|
||||
<span class="notice" style="width: 100%;">Warning! Exceeding 1200K will result in scan failure!</span>
|
||||
{{/if}}
|
||||
</div>
|
||||
@@ -123,12 +123,12 @@ Used In File(s): \code\modules\research\xenoarchaeology\machinery\geosample_scan
|
||||
<div class="item">
|
||||
<div class="itemLabel" style="width: 21%;">Ambient radiation:</div>
|
||||
<div class="itemContent" style="width: 35%;">
|
||||
{{:helper.displayBar(data.radiation, 0, 100, ((data.radiation > 15) ? ((data.radiation > 65) ? 'bad' : 'average') : 'good'))}}
|
||||
{{:data.radiation}} mSv
|
||||
{{:~displayBar(radiation, 0, 100, (radiation > 15 ? (radiation > 65 ? 'bad' : 'average') : 'good'))}}
|
||||
{{:radiation}} mSv
|
||||
</div>
|
||||
<div class="itemContent" style="width: 44%;">
|
||||
{{:helper.link(data.rad_shield_on ? 'Disable Radiation Shielding' : 'Enable Radiation Shielding', 'radiation', {'toggle_rad_shield' : 1}, null)}}
|
||||
{{if data.rad_shield_on}}
|
||||
{{:~link(rad_shield_on ? 'Disable Radiation Shielding' : 'Enable Radiation Shielding', 'radiation', {'toggle_rad_shield' : 1}, null)}}
|
||||
{{if rad_shield_on}}
|
||||
<span class="notice" style="width: 100%;">Shield blocking scanner.</span>
|
||||
{{/if}}
|
||||
</div>
|
||||
@@ -138,11 +138,11 @@ Used In File(s): \code\modules\research\xenoarchaeology\machinery\geosample_scan
|
||||
<div class="item">
|
||||
<div class="itemLabel" style="width: 21%;">Coolant remaining:</div>
|
||||
<div class="itemContent" style="width: 35%;">
|
||||
{{:helper.displayBar(data.unused_coolant_per, 0, 100, ((data.unused_coolant_per < 66) ? ((data.unused_coolant_per < 33) ? 'bad' : 'average') : 'good'))}}
|
||||
{{:data.unused_coolant_abs}} u
|
||||
{{:~displayBar(unused_coolant_per, 0, 100, (unused_coolant_per < 66 ? (unused_coolant_per < 33 ? 'bad' : 'average') : 'good'))}}
|
||||
{{:unused_coolant_abs}} u
|
||||
</div>
|
||||
<div class="itemContent" style="width: 44%;">
|
||||
{{if data.unused_coolant_per < 20}}
|
||||
{{if unused_coolant_per < 20}}
|
||||
<span class="notice" style="width: 100%;">Warning! Coolant stocks low!</span>
|
||||
{{/if}}
|
||||
</div>
|
||||
@@ -150,28 +150,28 @@ Used In File(s): \code\modules\research\xenoarchaeology\machinery\geosample_scan
|
||||
<div class="item">
|
||||
<div class="itemLabel" style="width: 21%;">Coolant flow rate:</div>
|
||||
<div class="itemContent" style="width: 35%;">
|
||||
{{:helper.displayBar(data.coolant_usage_rate, 0, 10, 'good')}}
|
||||
{{:data.coolant_usage_rate}} u/s
|
||||
{{:~displayBar(coolant_usage_rate, 0, 10, 'good')}}
|
||||
{{:coolant_usage_rate}} u/s
|
||||
</div>
|
||||
<div class="itemContent" style="text-align:left; width: 22%;">
|
||||
{{:helper.link('Min u/s', null, {'coolantRate' : -10}, null)}}
|
||||
{{:helper.link('-3 u/s', null, {'coolantRate' : -3}, null)}}
|
||||
{{:helper.link('-1 u/s', null, {'coolantRate' : -1}, null)}}
|
||||
{{:~link('Min u/s', null, {'coolantRate' : -10}, null)}}
|
||||
{{:~link('-3 u/s', null, {'coolantRate' : -3}, null)}}
|
||||
{{:~link('-1 u/s', null, {'coolantRate' : -1}, null)}}
|
||||
</div>
|
||||
<div class="itemContent" style="text-align:right; width: 22%;">
|
||||
{{:helper.link('+1 u/s', null, {'coolantRate' : 1}, null)}}
|
||||
{{:helper.link('+3 u/s', null, {'coolantRate' : 3}, null)}}
|
||||
{{:helper.link('Max u/s', null, {'coolantRate' : 10}, null)}}
|
||||
{{:~link('+1 u/s', null, {'coolantRate' : 1}, null)}}
|
||||
{{:~link('+3 u/s', null, {'coolantRate' : 3}, null)}}
|
||||
{{:~link('Max u/s', null, {'coolantRate' : 10}, null)}}
|
||||
</div>
|
||||
</div>
|
||||
<div class="item">
|
||||
<div class="itemLabel" style="width: 21%;">Coolant purity:</div>
|
||||
<div class="itemContent" style="width: 35%;">
|
||||
{{:helper.displayBar(data.coolant_purity, 0, 100, ((data.coolant_purity < 66) ? ((data.coolant_purity < 33) ? 'bad' : 'average') : 'good'))}}
|
||||
{{:data.coolant_purity}} %
|
||||
{{:~displayBar(coolant_purity, 0, 100, (coolant_purity < 66 ? (coolant_purity < 33 ? 'bad' : 'average') : 'good'))}}
|
||||
{{:coolant_purity}} %
|
||||
</div>
|
||||
<div class="itemContent" style="width: 44%;">
|
||||
{{if data.coolant_purity < 0.5}}
|
||||
{{if coolant_purity < 0.5}}
|
||||
<span class="notice" style="width: 100%;">Warning! Check coolant for contaminants!</span>
|
||||
{{/if}}
|
||||
</div>
|
||||
@@ -180,6 +180,6 @@ Used In File(s): \code\modules\research\xenoarchaeology\machinery\geosample_scan
|
||||
<h3>Latest Results</h3>
|
||||
<div class="statusDisplay">
|
||||
<div class="line">
|
||||
<span class="highlight">{{:data.last_scan_data}}</span>
|
||||
<span class="highlight">{{:last_scan_data}}</span>
|
||||
</div>
|
||||
</div>
|
||||
|
||||
Reference in New Issue
Block a user