fixes general air console and air sensor, oopsie

This commit is contained in:
SteelSlayer
2020-10-18 10:08:54 -05:00
parent 5e9b50b669
commit e2a80caace
+10
View File
@@ -118,6 +118,11 @@
signal.data["sigtype"]="status"
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
/obj/machinery/air_sensor/set_frequency(new_frequency)
SSradio.remove_object(src, frequency)
frequency = new_frequency
radio_connection = SSradio.add_object(src, frequency, RADIO_ATMOSIA)
/obj/machinery/air_sensor/Initialize()
..()
SSair.atmos_machinery += src
@@ -259,6 +264,11 @@
return output
/obj/machinery/computer/general_air_control/set_frequency(new_frequency)
SSradio.remove_object(src, frequency)
frequency = new_frequency
radio_connection = SSradio.add_object(src, frequency, RADIO_ATMOSIA)
/obj/machinery/computer/general_air_control/Initialize()
..()
set_frequency(frequency)