Files
Paradise/code/ATMOSPHERICS/components/binary_devices/volume_pump.dm
Fox McCloud 744777a944 Merge pull request #4971 from monster860/datum_browserify
Makes a bunch of UI's use /datum/browser
2016-07-16 08:52:18 -04:00

183 lines
5.0 KiB
Plaintext

/*
Every cycle, the pump uses the air in air_in to try and make air_out the perfect pressure.
node1, air1, network1 correspond to input
node2, air2, network2 correspond to output
Thus, the two variables affect pump operation are set in New():
air1.volume
This is the volume of gas available to the pump that may be transfered to the output
air2.volume
Higher quantities of this cause more air to be perfected later
but overall network volume is also increased as this increases...
*/
/obj/machinery/atmospherics/binary/volume_pump
icon = 'icons/atmos/volume_pump.dmi'
icon_state = "map_off"
name = "volumetric gas pump"
desc = "A volumetric pump"
can_unwrench = 1
var/on = 0
var/transfer_rate = 200
var/frequency = 0
var/id = null
var/datum/radio_frequency/radio_connection
/obj/machinery/atmospherics/binary/volume_pump/on
on = 1
icon_state = "map_on"
/obj/machinery/atmospherics/binary/volume_pump/initialize()
..()
set_frequency(frequency)
/obj/machinery/atmospherics/binary/volume_pump/update_icon()
if(!powered())
icon_state = "off"
else
icon_state = "[on ? "on" : "off"]"
/obj/machinery/atmospherics/binary/volume_pump/update_underlays()
if(..())
underlays.Cut()
var/turf/T = get_turf(src)
if(!istype(T))
return
add_underlay(T, node1, turn(dir, -180))
add_underlay(T, node2, dir)
/obj/machinery/atmospherics/binary/volume_pump/process()
if(!..() || (stat & (NOPOWER|BROKEN)) || !on)
return 0
// Pump mechanism just won't do anything if the pressure is too high/too low
var/input_starting_pressure = air1.return_pressure()
var/output_starting_pressure = air2.return_pressure()
if((input_starting_pressure < 0.01) || (output_starting_pressure > 9000))
return 1
var/transfer_ratio = max(1, transfer_rate/air1.volume)
var/datum/gas_mixture/removed = air1.remove_ratio(transfer_ratio)
air2.merge(removed)
parent1.update = 1
parent2.update = 1
return 1
/obj/machinery/atmospherics/binary/volume_pump/proc/set_frequency(new_frequency)
radio_controller.remove_object(src, frequency)
frequency = new_frequency
if(frequency)
radio_connection = radio_controller.add_object(src, frequency)
/obj/machinery/atmospherics/binary/volume_pump/proc/broadcast_status()
if(!radio_connection)
return 0
var/datum/signal/signal = new
signal.transmission_method = 1 //radio signal
signal.source = src
signal.data = list(
"tag" = id,
"device" = "APV",
"power" = on,
"transfer_rate" = transfer_rate,
"sigtype" = "status"
)
radio_connection.post_signal(src, signal)
return 1
/obj/machinery/atmospherics/binary/volume_pump/interact(mob/user as mob)
var/dat = {"<b>Power: </b><a href='?src=\ref[src];power=1'>[on?"On":"Off"]</a><br>
<b>Desirable output flow: </b>
[round(transfer_rate,1)]l/s | <a href='?src=\ref[src];set_transfer_rate=1'>Change</a>
"}
var/datum/browser/popup = new(user, "atmo_pump", name, 400, 400)
popup.set_content(dat)
popup.open(0)
onclose(user, "atmo_pump")
/obj/machinery/atmospherics/binary/volume_pump/receive_signal(datum/signal/signal)
if(!signal.data["tag"] || (signal.data["tag"] != id) || (signal.data["sigtype"]!="command"))
return 0
var/old_on = on //for logging
if(signal.data["power"])
on = text2num(signal.data["power"])
if(signal.data["power_toggle"])
on = !on
if(signal.data["set_transfer_rate"])
transfer_rate = between(
0,
text2num(signal.data["set_transfer_rate"]),
air1.volume
)
if(on != old_on)
investigate_log("was turned [on ? "on" : "off"] by a remote signal", "atmos")
if(signal.data["status"])
spawn(2)
broadcast_status()
return //do not update_icon
spawn(2)
broadcast_status()
update_icon()
/obj/machinery/atmospherics/binary/volume_pump/attack_hand(user as mob)
if(..())
return
src.add_fingerprint(usr)
if(!src.allowed(user))
to_chat(user, "<span class='alert'>Access denied.</span>")
return
usr.set_machine(src)
interact(user)
return
/obj/machinery/atmospherics/binary/volume_pump/Topic(href,href_list)
if(..())
return 1
if(href_list["power"])
on = !on
investigate_log("was turned [on ? "on" : "off"] by [key_name(usr)]", "atmos")
if(href_list["set_transfer_rate"])
var/new_transfer_rate = input(usr,"Enter new output volume (0-200l/s)","Flow control",src.transfer_rate) as num
src.transfer_rate = max(0, min(200, new_transfer_rate))
investigate_log("was set to [transfer_rate] L/s by [key_name(usr)]", "atmos")
usr.set_machine(src)
src.update_icon()
src.updateUsrDialog()
return
/obj/machinery/atmospherics/binary/volume_pump/power_change()
var/old_stat = stat
..()
if(old_stat != stat)
update_icon()
/obj/machinery/atmospherics/binary/volume_pump/attackby(var/obj/item/weapon/W as obj, var/mob/user as mob, params)
if(!istype(W, /obj/item/weapon/wrench))
return ..()
if(!(stat & NOPOWER) && on)
to_chat(user, "<span class='alert'>You cannot unwrench this [src], turn it off first.</span>")
return 1
return ..()