// channel numbers for power
#define EQUIP 1
#define LIGHT 2
#define ENVIRON 3
#define TOTAL 4 //for total power used only
#define STATIC_EQUIP 5
#define STATIC_LIGHT 6
#define STATIC_ENVIRON 7
//Power use
#define NO_POWER_USE 0
#define IDLE_POWER_USE 1
#define ACTIVE_POWER_USE 2
//computer3 error codes, move lower in the file when it passes dev -Sayu
#define PROG_CRASH 1 // Generic crash
#define MISSING_PERIPHERAL 2 // Missing hardware
#define BUSTED_ASS_COMPUTER 4 // Self-perpetuating error. BAC will continue to crash forever.
#define MISSING_PROGRAM 8 // Some files try to automatically launch a program. This is that failing.
#define FILE_DRM 16 // Some files want to not be copied/moved. This is them complaining that you tried.
#define NETWORK_FAILURE 32
#define IMPRINTER 1 //For circuits. Uses glass/chemicals.
#define PROTOLATHE 2 //New stuff. Uses glass/metal/chemicals
#define AUTOLATHE 4 //Uses glass/metal only.
#define CRAFTLATHE 8 //Uses fuck if I know. For use eventually.
#define MECHFAB 16 //Remember, objects utilising this flag should have construction_time and construction_cost vars.
// #define PODFAB 32 //Used by the spacepod part fabricator. Same idea as the mechfab // AA 2021-10-02 - Removed. Kept for flag consistency.
#define BIOGENERATOR 64 //Uses biomass
#define SMELTER 128 //uses various minerals
/// Used for gamma armoury lathe designs
#define GAMMALATHE 256
//Note: More then one of these can be added to a design but imprinter and lathe designs are incompatable.
#define HYDRO_SPEED_MULTIPLIER 1
//Modular computer/NTNet defines
//Modular computer part defines
#define MC_CPU "CPU"
#define MC_HDD "HDD"
#define MC_SDD "SDD"
#define MC_CARD "CARD"
#define MC_NET "NET"
#define MC_PRINT "PRINT"
#define MC_CELL "CELL"
#define MC_CHARGE "CHARGE"
#define MC_AI "AI"
//NTNet stuff, for modular computers
// NTNet module-configuration values. Do not change these. If you need to add another use larger number (5..6..7 etc)
#define NTNET_SOFTWAREDOWNLOAD 1 // Downloads of software from NTNet
#define NTNET_PEERTOPEER 2 // P2P transfers of files between devices
#define NTNET_COMMUNICATION 3 // Communication (messaging)
#define NTNET_SYSTEMCONTROL 4 // Control of various systems, RCon, air alarm control, etc.
//NTNet transfer speeds, used when downloading/uploading a file/program.
#define NTNETSPEED_LOWSIGNAL 0.5 // GQ/s transfer speed when the device is wirelessly connected and on Low signal
#define NTNETSPEED_HIGHSIGNAL 1 // GQ/s transfer speed when the device is wirelessly connected and on High signal
#define NTNETSPEED_ETHERNET 2 // GQ/s transfer speed when the device is using wired connection
//Caps for NTNet logging. Less than 10 would make logging useless anyway, more than 500 may make the log browser too laggy. Defaults to 100 unless user changes it.
#define MAX_NTNET_LOGS 300
#define MIN_NTNET_LOGS 10
//Program bitflags
#define PROGRAM_ALL 7
#define PROGRAM_CONSOLE 1
#define PROGRAM_LAPTOP 2
#define PROGRAM_TABLET 4
//Program states
#define PROGRAM_STATE_KILLED 0
#define PROGRAM_STATE_BACKGROUND 1
#define PROGRAM_STATE_ACTIVE 2
// Demotion Console (card/minor/*) departments
#define TARGET_DEPT_GENERIC 1
#define TARGET_DEPT_SEC 2
#define TARGET_DEPT_MED 3
#define TARGET_DEPT_SCI 4
#define TARGET_DEPT_ENG 5
// These are used by supermatter and supermatter monitor program, mostly for UI updating purposes. Higher should always be worse!
// These are warning defines, they should trigger before the state, not after.
#define SUPERMATTER_ERROR -1 // Unknown status, shouldn't happen but just in case.
#define SUPERMATTER_INACTIVE 0 // No or minimal energy
#define SUPERMATTER_NORMAL 1 // Normal operation
#define SUPERMATTER_NOTIFY 2 // Ambient temp > 80% of CRITICAL_TEMPERATURE
#define SUPERMATTER_WARNING 3 // Ambient temp > CRITICAL_TEMPERATURE OR integrity damaged
#define SUPERMATTER_DANGER 4 // Integrity < 75%
#define SUPERMATTER_EMERGENCY 5 // Integrity < 50%
#define SUPERMATTER_DELAMINATING 6 // Pretty obvious, Integrity < 25%
//APC charging
#define APC_NOT_CHARGING 0
#define APC_IS_CHARGING 1
#define APC_FULLY_CHARGED 2
// Firelock states
#define FD_OPEN 1
#define FD_CLOSED 2
// Computer login types
#define LOGIN_TYPE_NORMAL 1
#define LOGIN_TYPE_AI 2
#define LOGIN_TYPE_ROBOT 3
#define LOGIN_TYPE_ADMIN 4
// Status display maptext stuff
#define DISPLAY_CHARS_PER_LINE 5
#define DISPLAY_FONT_SIZE "5pt"
#define DISPLAY_FONT_COLOR "#09f"
#define DISPLAY_WARNING_FONT_COLOR "#f90"
#define DISPLAY_FONT_STYLE "Small Fonts"
#define DISPLAY_SCROLL_SPEED 2
// Status display mode types
#define STATUS_DISPLAY_BLANK 0
#define STATUS_DISPLAY_TRANSFER_SHUTTLE_TIME 1
#define STATUS_DISPLAY_MESSAGE 2
#define STATUS_DISPLAY_ALERT 3
#define STATUS_DISPLAY_TIME 4
#define STATUS_DISPLAY_CUSTOM 5
// AI display mode types
#define AI_DISPLAY_MODE_BLANK 0
#define AI_DISPLAY_MODE_EMOTE 1
#define AI_DISPLAY_MODE_BSOD 2
// Door operations
#define DOOR_OPENING 1
#define DOOR_CLOSING 2
#define DOOR_MALF 3