SUBSYSTEM_DEF(nightshift)
name = "Night Shift"
dependencies = list(
/datum/controller/subsystem/lighting
)
priority = FIRE_PRIORITY_NIGHTSHIFT
wait = 60 SECONDS
var/nightshift_active = FALSE
var/nightshift_first_check = 30 SECONDS
var/high_security_mode = FALSE
var/list/currentrun
/datum/controller/subsystem/nightshift/Initialize()
if(!CONFIG_GET(flag/enable_night_shifts))
can_fire = FALSE
return SS_INIT_SUCCESS
/datum/controller/subsystem/nightshift/fire(resumed = FALSE)
if(resumed)
update_nightshift(resumed = TRUE)
return
if(world.time - SSticker.round_start_time < nightshift_first_check)
return
check_nightshift()
/datum/controller/subsystem/nightshift/proc/announce(message)
var/announce_z
if(length(using_map.station_levels))
announce_z = pick(using_map.station_levels)
var/pickedsound
if(!high_security_mode)
if(nightshift_active)
pickedsound = ANNOUNCER_MSG_NIGHTSHIFT_START
else
pickedsound = ANNOUNCER_MSG_NIGHTSHIFT_END
GLOB.priority_announcement.Announce(message, new_title = "Automated Lighting System Announcement", new_sound = pickedsound, zlevel = announce_z)
/datum/controller/subsystem/nightshift/proc/check_nightshift(forced) //This is called from elsewhere, like setting the alert levels, sadly
var/emergency = GLOB.security_level > SEC_LEVEL_GREEN
var/announcing = TRUE
var/night_time = using_map.get_nightshift()
if(high_security_mode != emergency)
high_security_mode = emergency
if(night_time)
announcing = FALSE
if(!emergency)
announce("Restoring night lighting configuration to normal operation.")
else
announce("Disabling night lighting: Station is in a state of emergency.")
if(emergency)
night_time = FALSE
if(nightshift_active != night_time)
update_nightshift(night_time, announcing, forced = forced)
/datum/controller/subsystem/nightshift/proc/update_nightshift(active, announce = TRUE, resumed = FALSE, forced = FALSE)
if(!resumed)
currentrun = GLOB.apcs
nightshift_active = active
if(announce)
if (active)
announce("Good evening, crew. To reduce power consumption and stimulate the circadian rhythms of some species, all of the lights aboard the station have been dimmed for the night.")
else
announce("Good morning, crew. As it is now day time, all of the lights aboard the station have been restored to their former brightness.")
for(var/obj/machinery/power/apc/apc as anything in currentrun)
currentrun -= apc
if(apc.z in using_map.station_levels)
apc.set_nightshift(active, TRUE)
if(MC_TICK_CHECK && !forced) // subsystem will be in state SS_IDLE if forced by an admin
return