modules: A to C

This commit is contained in:
deathride58
2018-01-04 00:46:53 -05:00
parent d26a9b23a4
commit 0dbc2241ea
69 changed files with 822 additions and 771 deletions
@@ -15,6 +15,7 @@
anchored = TRUE
density = TRUE
var/global/const/CIRC_LEFT = 1
var/global/const/CIRC_RIGHT = 2
@@ -39,6 +40,8 @@
var/transfer_moles = pressure_delta*air1.volume/(air2.temperature * R_IDEAL_GAS_EQUATION)
last_pressure_delta = pressure_delta
//Actually transfer the gas
var/datum/gas_mixture/removed = air2.remove(transfer_moles)
update_parents()
@@ -131,17 +131,13 @@ Acts like a normal vent, but has an input AND output.
SSradio.remove_object(src, frequency)
frequency = new_frequency
if(frequency)
radio_connection = SSradio.add_object(src, frequency, filter = GLOB.RADIO_ATMOSIA)
radio_connection = SSradio.add_object(src, frequency, filter = RADIO_ATMOSIA)
/obj/machinery/atmospherics/components/binary/dp_vent_pump/proc/broadcast_status()
if(!radio_connection)
return
var/datum/signal/signal = new
signal.transmission_method = 1 //radio signal
signal.source = src
signal.data = list(
var/datum/signal/signal = new(list(
"tag" = id,
"device" = "ADVP",
"power" = on,
@@ -151,8 +147,8 @@ Acts like a normal vent, but has an input AND output.
"output" = output_pressure_max,
"external" = external_pressure_bound,
"sigtype" = "status"
)
radio_connection.post_signal(src, signal, filter = GLOB.RADIO_ATMOSIA)
))
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
/obj/machinery/atmospherics/components/binary/dp_vent_pump/atmosinit()
..()
@@ -72,25 +72,20 @@ Passive gate is similar to the regular pump except:
SSradio.remove_object(src, frequency)
frequency = new_frequency
if(frequency)
radio_connection = SSradio.add_object(src, frequency, filter = GLOB.RADIO_ATMOSIA)
radio_connection = SSradio.add_object(src, frequency, filter = RADIO_ATMOSIA)
/obj/machinery/atmospherics/components/binary/passive_gate/proc/broadcast_status()
if(!radio_connection)
return
var/datum/signal/signal = new
signal.transmission_method = 1 //radio signal
signal.source = src
signal.data = list(
var/datum/signal/signal = new(list(
"tag" = id,
"device" = "AGP",
"power" = on,
"target_output" = target_pressure,
"sigtype" = "status"
)
radio_connection.post_signal(src, signal, filter = GLOB.RADIO_ATMOSIA)
))
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
/obj/machinery/atmospherics/components/binary/passive_gate/ui_interact(mob/user, ui_key = "main", datum/tgui/ui = null, force_open = FALSE, \
datum/tgui/master_ui = null, datum/ui_state/state = GLOB.default_state)
@@ -75,25 +75,20 @@ Thus, the two variables affect pump operation are set in New():
SSradio.remove_object(src, frequency)
frequency = new_frequency
if(frequency)
radio_connection = SSradio.add_object(src, frequency, filter = GLOB.RADIO_ATMOSIA)
radio_connection = SSradio.add_object(src, frequency, filter = RADIO_ATMOSIA)
/obj/machinery/atmospherics/components/binary/pump/proc/broadcast_status()
if(!radio_connection)
return
var/datum/signal/signal = new
signal.transmission_method = 1 //radio signal
signal.source = src
signal.data = list(
var/datum/signal/signal = new(list(
"tag" = id,
"device" = "AGP",
"power" = on,
"target_output" = target_pressure,
"sigtype" = "status"
)
radio_connection.post_signal(src, signal, filter = GLOB.RADIO_ATMOSIA)
))
radio_connection.post_signal(src, signal, filter = RADIO_ATMOSIA)
/obj/machinery/atmospherics/components/binary/pump/ui_interact(mob/user, ui_key = "main", datum/tgui/ui = null, force_open = FALSE, \
datum/tgui/master_ui = null, datum/ui_state/state = GLOB.default_state)
@@ -77,17 +77,13 @@ Thus, the two variables affect pump operation are set in New():
if(!radio_connection)
return
var/datum/signal/signal = new
signal.transmission_method = 1 //radio signal
signal.source = src
signal.data = list(
var/datum/signal/signal = new(list(
"tag" = id,
"device" = "APV",
"power" = on,
"transfer_rate" = transfer_rate,
"sigtype" = "status"
)
))
radio_connection.post_signal(src, signal)
/obj/machinery/atmospherics/components/binary/volume_pump/ui_interact(mob/user, ui_key = "main", datum/tgui/ui = null, force_open = FALSE, \
@@ -29,7 +29,7 @@
SSradio.remove_object(src, frequency)
frequency = new_frequency
if(frequency)
radio_connection = SSradio.add_object(src, frequency, GLOB.RADIO_ATMOSIA)
radio_connection = SSradio.add_object(src, frequency, RADIO_ATMOSIA)
/obj/machinery/atmospherics/components/trinary/filter/New()
..()
@@ -42,7 +42,7 @@
radio = new(src)
radio.keyslot = new radio_key
radio.subspace_transmission = 1
radio.subspace_transmission = TRUE
radio.canhear_range = 0
radio.recalculateChannels()
@@ -182,7 +182,7 @@
mob_occupant.Unconscious((mob_occupant.bodytemperature * unconscious_factor) * 2000)
if(beaker)
if(reagent_transfer == 0) // Magically transfer reagents. Because cryo magic.
beaker.reagents.trans_to(occupant, 1, 10 * efficiency) // Transfer reagents, multiplied because cryo magic.
beaker.reagents.trans_to(occupant, 1, efficiency * 0.25) // Transfer reagents.
beaker.reagents.reaction(occupant, VAPOR)
air1.gases[/datum/gas/oxygen][MOLES] -= 2 / efficiency //Let's use gas for this
if(++reagent_transfer >= 10 * efficiency) // Throttle reagent transfer (higher efficiency will transfer the same amount but consume less from the beaker).
@@ -93,19 +93,14 @@
if(!radio_connection)
return
var/datum/signal/signal = new
signal.transmission_method = 1 //radio signal
signal.source = src
signal.data = list(
var/datum/signal/signal = new(list(
"tag" = id,
"device" = "AO",
"power" = on,
"volume_rate" = volume_rate,
//"timestamp" = world.time,
"sigtype" = "status"
)
))
radio_connection.post_signal(src, signal)
/obj/machinery/atmospherics/components/unary/outlet_injector/atmosinit()
@@ -26,7 +26,7 @@
// INT_BOUND: Do not pass internal_pressure_bound
// NO_BOUND: Do not pass either
var/frequency = 1439
var/frequency = FREQ_ATMOS_CONTROL
var/datum/radio_frequency/radio_connection
var/radio_filter_out
var/radio_filter_in
@@ -178,11 +178,7 @@
if(!radio_connection)
return
var/datum/signal/signal = new
signal.transmission_method = 1 // radio signal
signal.source = src
signal.data = list(
var/datum/signal/signal = new(list(
"tag" = id_tag,
"frequency" = frequency,
"device" = "VP",
@@ -193,7 +189,7 @@
"internal" = internal_pressure_bound,
"external" = external_pressure_bound,
"sigtype" = "status"
)
))
var/area/A = get_area(src)
if(!A.air_vent_names[id_tag])
@@ -206,8 +202,8 @@
/obj/machinery/atmospherics/components/unary/vent_pump/atmosinit()
//some vents work his own spesial way
radio_filter_in = frequency==1439?(GLOB.RADIO_FROM_AIRALARM):null
radio_filter_out = frequency==1439?(GLOB.RADIO_TO_AIRALARM):null
radio_filter_in = frequency==FREQ_ATMOS_CONTROL?(RADIO_FROM_AIRALARM):null
radio_filter_out = frequency==FREQ_ATMOS_CONTROL?(RADIO_TO_AIRALARM):null
if(frequency)
set_frequency(frequency)
broadcast_status()
@@ -23,7 +23,7 @@
var/widenet = 0 //is this scrubber acting on the 3x3 area around it.
var/list/turf/adjacent_turfs = list()
var/frequency = 1439
var/frequency = FREQ_ATMOS_CONTROL
var/datum/radio_frequency/radio_connection
var/radio_filter_out
var/radio_filter_in
@@ -81,7 +81,7 @@
icon_state = "scrub_off"
return
if(scrubbing & SCRUBBING)
if(scrubbing & SCRUBBING)
if(widenet)
icon_state = "scrub_wide"
else
@@ -98,16 +98,12 @@
if(!radio_connection)
return FALSE
var/datum/signal/signal = new
signal.transmission_method = 1 //radio signal
signal.source = src
var/list/f_types = list()
for(var/path in GLOB.meta_gas_info)
var/list/gas = GLOB.meta_gas_info[path]
f_types += list(list("gas_id" = gas[META_GAS_ID], "gas_name" = gas[META_GAS_NAME], "enabled" = (path in filter_types)))
signal.data = list(
var/datum/signal/signal = new(list(
"tag" = id_tag,
"frequency" = frequency,
"device" = "VS",
@@ -117,7 +113,7 @@
"widenet" = widenet,
"filter_types" = f_types,
"sigtype" = "status"
)
))
var/area/A = get_area(src)
if(!A.air_scrub_names[id_tag])
@@ -130,8 +126,8 @@
return TRUE
/obj/machinery/atmospherics/components/unary/vent_scrubber/atmosinit()
radio_filter_in = frequency==initial(frequency)?(GLOB.RADIO_FROM_AIRALARM):null
radio_filter_out = frequency==initial(frequency)?(GLOB.RADIO_TO_AIRALARM):null
radio_filter_in = frequency==initial(frequency)?(RADIO_FROM_AIRALARM):null
radio_filter_out = frequency==initial(frequency)?(RADIO_TO_AIRALARM):null
if(frequency)
set_frequency(frequency)
broadcast_status()
@@ -205,7 +201,7 @@
return TRUE
//There is no easy way for an object to be notified of changes to atmos can pass flags_1
//There is no easy way for an object to be notified of changes to atmos can pass flags
// So we check every machinery process (2 seconds)
/obj/machinery/atmospherics/components/unary/vent_scrubber/process()
if(widenet)