nightshift changes

This commit is contained in:
kevinz000
2020-01-02 23:56:40 -08:00
parent 82db38d5d6
commit 8e1affa1f5
7 changed files with 128 additions and 65 deletions
+6
View File
@@ -530,3 +530,9 @@ GLOBAL_LIST_INIT(pda_reskins, list(PDA_SKIN_CLASSIC = 'icons/obj/pda.dmi', PDA_S
#define CRYOMOBS 'icons/obj/cryo_mobs.dmi'
#define CANT_REENTER_ROUND -1
//Nightshift levels.
#define NIGHTSHIFT_AREA_NONE 0 //default
#define NIGHTSHIFT_AREA_PUBLIC 1 //hallways
#define NIGHTSHIFT_AREA_RECREATION 2 //dorms common areas, etc
#define NIGHTSHIFT_AREA_DEPARTMENT_HALLS 3 //interior hallways, etc
@@ -362,6 +362,15 @@
/datum/config_entry/flag/enable_night_shifts
/datum/config_entry/number/night_shift_public_areas_only
config_entry_value = NIGHTSHIFT_AREA_PUBLIC
/datum/config_entry/flag/nightshift_toggle_requires_auth
config_entry_value = FALSE
/datum/config_entry/flag/nightshift_toggle_public_requires_auth
config_entry_value = TRUE
/datum/config_entry/flag/randomize_shift_time
/datum/config_entry/flag/shift_time_realtime
+4 -4
View File
@@ -35,21 +35,21 @@ SUBSYSTEM_DEF(nightshift)
if(!emergency)
announce("Restoring night lighting configuration to normal operation.")
else
announce("Disabling night lighting: Station is in a state of emergency.")
announce("Disabling night lighting: Station is in a state of emergency.")
if(emergency)
night_time = FALSE
if(nightshift_active != night_time)
update_nightshift(night_time, announcing)
/datum/controller/subsystem/nightshift/proc/update_nightshift(active, announce = TRUE)
/datum/controller/subsystem/nightshift/proc/update_nightshift(active, announce = TRUE, max_level = (!active? INFINITY : CONFIG_GET(number/night_shift_public_area_only)))
nightshift_active = active
if(announce)
if (active)
announce("Good evening, crew. To reduce power consumption and stimulate the circadian rhythms of some species, all of the lights aboard the station have been dimmed for the night.")
else
announce("Good morning, crew. As it is now day time, all of the lights aboard the station have been restored to their former brightness.")
var/public_only = CONFIG_GET(number/night_shift_public_area_only)
for(var/A in GLOB.apcs_list)
var/obj/machinery/power/apc/APC = A
if (APC.area && (APC.area.type in GLOB.the_station_areas))
if(APC.area && (!max_level || !APC.area.nightshift_public_area || (APC.area.nightshift_public_area <= max_level)) && (APC.area.type in GLOB.the_station_areas))
APC.set_nightshift(active)
CHECK_TICK
+17
View File
@@ -259,6 +259,9 @@ NOTE: there are two lists of areas in the end of this file: centcom and station
//Hallway
/area/hallway
nightshift_public_area = NIGHTSHIFT_AREA_PUBLIC
/area/hallway/primary/aft
name = "Aft Primary Hallway"
icon_state = "hallA"
@@ -404,14 +407,17 @@ NOTE: there are two lists of areas in the end of this file: centcom and station
name = "Dormitories"
icon_state = "Sleep"
safe = TRUE
nightshift_public_area = NIGHTSHIFT_AREA_RECREATION
/area/crew_quarters/dorms/male
name = "Male Dorm"
icon_state = "Sleep"
nightshift_public_area = NIGHTSHIFT_AREA_NONE
/area/crew_quarters/dorms/female
name = "Female Dorm"
icon_state = "Sleep"
nightshift_public_area = NIGHTSHIFT_AREA_NONE
/area/crew_quarters/rehab_dome
name = "Rehabilitation Dome"
@@ -448,26 +454,32 @@ NOTE: there are two lists of areas in the end of this file: centcom and station
/area/crew_quarters/locker
name = "Locker Room"
icon_state = "locker"
nightshift_public_area = NIGHTSHIFT_AREA_RECREATION
/area/crew_quarters/lounge
name = "Lounge"
icon_state = "yellow"
nightshift_public_area = NIGHTSHIFT_AREA_RECREATION
/area/crew_quarters/fitness
name = "Fitness Room"
icon_state = "fitness"
nightshift_public_area = NIGHTSHIFT_AREA_RECREATION
/area/crew_quarters/fitness/recreation
name = "Recreation Area"
icon_state = "fitness"
nightshift_public_area = NIGHTSHIFT_AREA_RECREATION
/area/crew_quarters/cafeteria
name = "Cafeteria"
icon_state = "cafeteria"
nightshift_public_area = NIGHTSHIFT_AREA_RECREATION
/area/crew_quarters/cafeteria/lunchroom
name = "Lunchroom"
icon_state = "cafeteria"
nightshift_public_area = NIGHTSHIFT_AREA_RECREATION
/area/crew_quarters/kitchen
name = "Kitchen"
@@ -480,6 +492,7 @@ NOTE: there are two lists of areas in the end of this file: centcom and station
/area/crew_quarters/bar
name = "Bar"
icon_state = "bar"
nightshift_public_area = NIGHTSHIFT_AREA_RECREATION
/area/crew_quarters/bar/atrium
name = "Atrium"
@@ -518,6 +531,7 @@ NOTE: there are two lists of areas in the end of this file: centcom and station
name = "Library"
icon_state = "library"
flags_1 = NONE
nightshift_public_area = NIGHTSHIFT_AREA_RECREATION
/area/library/lounge
name = "Library Lounge"
@@ -527,6 +541,7 @@ NOTE: there are two lists of areas in the end of this file: centcom and station
name = "Abandoned Library"
icon_state = "library"
flags_1 = NONE
nightshift_public_area = NIGHTSHIFT_AREA_NONE
/area/chapel
icon_state = "chapel"
@@ -534,12 +549,14 @@ NOTE: there are two lists of areas in the end of this file: centcom and station
flags_1 = NONE
clockwork_warp_allowed = FALSE
clockwork_warp_fail = "The consecration here prevents you from warping in."
nightshift_public_area = NIGHTSHIFT_AREA_RECREATION
/area/chapel/main
name = "Chapel"
/area/chapel/main/monastery
name = "Monastery"
nightshift_public_area = NIGHTSHIFT_AREA_NONE
/area/chapel/office
name = "Chapel Office"
+2
View File
@@ -63,6 +63,8 @@
var/xenobiology_compatible = FALSE //Can the Xenobio management console transverse this area by default?
var/list/canSmoothWithAreas //typecache to limit the areas that atoms in this area can smooth with
var/nightshift_public_area = NIGHTSHIFT_AREA_NONE //considered a public area for nightshift
/*Adding a wizard area teleport list because motherfucking lag -- Urist*/
/*I am far too lazy to make it a proper list of areas so I'll just make it run the usual telepot routine at the start of the game*/
GLOBAL_LIST_EMPTY(teleportlocs)
+80 -60
View File
@@ -98,6 +98,7 @@
var/force_update = 0
var/emergency_lights = FALSE
var/nightshift_lights = FALSE
var/nightshift_requires_auth = FALSE
var/last_nightshift_switch = 0
var/update_state = -1
var/update_overlay = -1
@@ -239,6 +240,7 @@
update_icon()
make_terminal()
update_nightshift_auth_requirement()
addtimer(CALLBACK(src, .proc/update), 5)
@@ -806,6 +808,7 @@
/obj/machinery/power/apc/ui_data(mob/user)
var/list/data = list(
"locked" = locked && !(integration_cog && is_servant_of_ratvar(user)),
"lock_nightshift" = nightshift_requires_auth,
"failTime" = failure_timer,
"isOperating" = operating,
"externalPower" = main_status,
@@ -913,70 +916,73 @@
. = UI_INTERACTIVE
/obj/machinery/power/apc/ui_act(action, params)
if(..() || !can_use(usr, 1) || (locked && !usr.has_unlimited_silicon_privilege && !failure_timer && !(integration_cog && (is_servant_of_ratvar(usr)))))
if(..() || !can_use(usr, 1))
return
switch(action)
if("lock")
if(usr.has_unlimited_silicon_privilege)
if((obj_flags & EMAGGED) || (stat & (BROKEN|MAINT)))
to_chat(usr, "The APC does not respond to the command.")
else
locked = !locked
update_icon()
. = TRUE
if("cover")
coverlocked = !coverlocked
. = TRUE
if("breaker")
toggle_breaker()
. = TRUE
if("toggle_nightshift")
toggle_nightshift_lights()
. = TRUE
if("charge")
chargemode = !chargemode
if(!chargemode)
charging = APC_NOT_CHARGING
update_icon()
. = TRUE
if("channel")
if(params["eqp"])
equipment = setsubsystem(text2num(params["eqp"]))
update_icon()
update()
else if(params["lgt"])
lighting = setsubsystem(text2num(params["lgt"]))
update_icon()
update()
else if(params["env"])
environ = setsubsystem(text2num(params["env"]))
update_icon()
update()
. = TRUE
if("overload")
if(usr.has_unlimited_silicon_privilege)
overload_lighting()
. = TRUE
if("hack")
if(get_malf_status(usr))
malfhack(usr)
if("occupy")
if(get_malf_status(usr))
malfoccupy(usr)
if("deoccupy")
if(get_malf_status(usr))
malfvacate()
if("reboot")
if(failure_timer)
if(action == "reboot")
failure_timer = 0
update_icon()
update()
if("emergency_lighting")
emergency_lights = !emergency_lights
for(var/obj/machinery/light/L in area)
if(!initial(L.no_emergency)) //If there was an override set on creation, keep that override
L.no_emergency = emergency_lights
INVOKE_ASYNC(L, /obj/machinery/light/.proc/update, FALSE)
CHECK_TICK
var/authorized = (!locked || !usr.has_unlimited_silicon_privilege || failure_timer || (integration_cog && (is_servant_of_ratvar(usr))))
if((action == "toggle_nightshift") && (!nightshift_requires_auth || authorized))
toggle_nightshift_lights()
. = TRUE
if(authorized)
switch(action)
if("lock")
if(usr.has_unlimited_silicon_privilege)
if((obj_flags & EMAGGED) || (stat & (BROKEN|MAINT)))
to_chat(usr, "The APC does not respond to the command.")
else
locked = !locked
update_icon()
. = TRUE
if("cover")
coverlocked = !coverlocked
. = TRUE
if("breaker")
toggle_breaker()
. = TRUE
if("charge")
chargemode = !chargemode
if(!chargemode)
charging = APC_NOT_CHARGING
update_icon()
. = TRUE
if("channel")
if(params["eqp"])
equipment = setsubsystem(text2num(params["eqp"]))
update_icon()
update()
else if(params["lgt"])
lighting = setsubsystem(text2num(params["lgt"]))
update_icon()
update()
else if(params["env"])
environ = setsubsystem(text2num(params["env"]))
update_icon()
update()
. = TRUE
if("overload")
if(usr.has_unlimited_silicon_privilege)
overload_lighting()
. = TRUE
if("hack")
if(get_malf_status(usr))
malfhack(usr)
if("occupy")
if(get_malf_status(usr))
malfoccupy(usr)
if("deoccupy")
if(get_malf_status(usr))
malfvacate()
if("emergency_lighting")
emergency_lights = !emergency_lights
for(var/obj/machinery/light/L in area)
if(!initial(L.no_emergency)) //If there was an override set on creation, keep that override
L.no_emergency = emergency_lights
INVOKE_ASYNC(L, /obj/machinery/light/.proc/update, FALSE)
CHECK_TICK
return 1
/obj/machinery/power/apc/proc/toggle_breaker()
@@ -1383,6 +1389,8 @@
/obj/machinery/power/apc/proc/set_nightshift(on)
set waitfor = FALSE
if(nightshift_lights == on)
return
nightshift_lights = on
for(var/obj/machinery/light/L in area)
if(L.nightshift_allowed)
@@ -1390,6 +1398,18 @@
L.update(FALSE)
CHECK_TICK
/obj/machinery/power/apc/proc/update_nightshift_auth_requirement()
nightshift_requires_auth = nightshift_toggle_requires_auth()
/obj/machinery/power/apc/proc/nightshift_toggle_requires_auth()
if(!area)
return FALSE
var/configured_level = CONFIG_GET(number/nightshift_public_areas_only)
var/our_level = area.nightshift_public_area
var/public_requires_auth = CONFIG_GET(flag/nightshift_toggle_public_requires_auth)
var/normal_requires_auth = CONFIG_GET(flag/nightshift_toggle_requires_auth)
return (configured_level && our_level && (our_level <= configured_level))? public_requires_auth : normal_requires_auth)
#undef UPSTATE_CELL_IN
#undef UPSTATE_OPENED1
#undef UPSTATE_OPENED2
+10 -1
View File
@@ -560,6 +560,15 @@ ROUNDSTART_TRAITS
## Enable night shifts ##
#ENABLE_NIGHT_SHIFTS
## Makes night shifts only affect in-code public-flagged areas. Nightshifts hit the level as defined in __DEFINES/misc.dm that this is set to and anything below. ##
NIGHT_SHIFT_PUBLIC_AREAS_ONLY 1
## Nightshift toggles REQUIRE APC authorization ##
#NIGHTSHIFT_TOGGLE_REQUIRES_AUTH
## Nightshift toggles in public areas REQUIRE APC authorization ##
NIGHTSHIFT_TOGGLE_PUBLIC_REQUIRES_AUTH
## Enable randomized shift start times##
#RANDOMIZE_SHIFT_TIME
@@ -578,4 +587,4 @@ DYNAMIC_VOTING
## Choose which Engine to start the round with, comment to remove an Engine from the rotation
BOX_RANDOM_ENGINE Engine SM
BOX_RANDOM_ENGINE Engine Tesla
BOX_RANDOM_ENGINE Engine Singulo
BOX_RANDOM_ENGINE Engine Singulo