Merge branch 'master' of https://github.com/Citadel-Station-13/Citadel-Station-13 into hijackbackup
This commit is contained in:
+40
-16
@@ -98,6 +98,7 @@
|
||||
var/force_update = 0
|
||||
var/emergency_lights = FALSE
|
||||
var/nightshift_lights = FALSE
|
||||
var/nightshift_requires_auth = FALSE
|
||||
var/last_nightshift_switch = 0
|
||||
var/update_state = -1
|
||||
var/update_overlay = -1
|
||||
@@ -241,6 +242,7 @@
|
||||
update_icon()
|
||||
|
||||
make_terminal()
|
||||
update_nightshift_auth_requirement()
|
||||
|
||||
addtimer(CALLBACK(src, .proc/update), 5)
|
||||
|
||||
@@ -862,6 +864,7 @@
|
||||
/obj/machinery/power/apc/ui_data(mob/user)
|
||||
var/list/data = list(
|
||||
"locked" = locked && !(integration_cog && is_servant_of_ratvar(user)) && !hasSiliconAccessInArea(user,area),
|
||||
"lock_nightshift" = nightshift_requires_auth,
|
||||
"failTime" = failure_timer,
|
||||
"isOperating" = operating,
|
||||
"externalPower" = main_status,
|
||||
@@ -973,10 +976,21 @@
|
||||
. = UI_INTERACTIVE
|
||||
|
||||
/obj/machinery/power/apc/ui_act(action, params)
|
||||
if (action == "hijack" && can_use(usr, 1))
|
||||
if(..() || !can_use(usr, 1))
|
||||
return
|
||||
if(failure_timer)
|
||||
if(action == "reboot")
|
||||
failure_timer = 0
|
||||
update_icon()
|
||||
update()
|
||||
if (action == "hijack" && can_use(usr, 1)) //don't need auth for hijack button
|
||||
hijack(usr)
|
||||
return
|
||||
if(..() || !can_use(usr, 1) || (locked && !hasSiliconAccessInArea(usr,area) && !usr.has_unlimited_silicon_privilege && !failure_timer && !(integration_cog && (is_servant_of_ratvar(usr)))))
|
||||
var/authorized = (!locked || usr.has_unlimited_silicon_privilege || hasSiliconAccessInArea(usr,area) || (integration_cog && (is_servant_of_ratvar(usr))))
|
||||
if((action == "toggle_nightshift") && (!nightshift_requires_auth || authorized))
|
||||
toggle_nightshift_lights()
|
||||
return TRUE
|
||||
if(!authorized)
|
||||
return
|
||||
switch(action)
|
||||
if("lock")
|
||||
@@ -986,22 +1000,19 @@
|
||||
else
|
||||
locked = !locked
|
||||
update_icon()
|
||||
. = TRUE
|
||||
return TRUE
|
||||
if("cover")
|
||||
coverlocked = !coverlocked
|
||||
. = TRUE
|
||||
return TRUE
|
||||
if("breaker")
|
||||
toggle_breaker()
|
||||
. = TRUE
|
||||
if("toggle_nightshift")
|
||||
toggle_nightshift_lights()
|
||||
. = TRUE
|
||||
return TRUE
|
||||
if("charge")
|
||||
chargemode = !chargemode
|
||||
if(!chargemode)
|
||||
charging = APC_NOT_CHARGING
|
||||
update_icon()
|
||||
. = TRUE
|
||||
return TRUE
|
||||
if("channel")
|
||||
if(params["eqp"])
|
||||
equipment = setsubsystem(text2num(params["eqp"]))
|
||||
@@ -1015,24 +1026,23 @@
|
||||
environ = setsubsystem(text2num(params["env"]))
|
||||
update_icon()
|
||||
update()
|
||||
. = TRUE
|
||||
return TRUE
|
||||
if("overload")
|
||||
if(usr.has_unlimited_silicon_privilege || hasSiliconAccessInArea(usr,area))
|
||||
overload_lighting()
|
||||
. = TRUE
|
||||
return TRUE
|
||||
if("hack")
|
||||
if(get_malf_status(usr))
|
||||
malfhack(usr)
|
||||
return TRUE
|
||||
if("occupy")
|
||||
if(get_malf_status(usr))
|
||||
malfoccupy(usr)
|
||||
return TRUE
|
||||
if("deoccupy")
|
||||
if(get_malf_status(usr))
|
||||
malfvacate()
|
||||
if("reboot")
|
||||
failure_timer = 0
|
||||
update_icon()
|
||||
update()
|
||||
return TRUE
|
||||
if("emergency_lighting")
|
||||
emergency_lights = !emergency_lights
|
||||
for(var/obj/machinery/light/L in area)
|
||||
@@ -1055,7 +1065,7 @@
|
||||
INVOKE_ASYNC(D,/obj/machinery/door.proc/hostile_lockdown,usr, FALSE)
|
||||
addtimer(CALLBACK(D,/obj/machinery/door.proc/disable_lockdown, FALSE), 30 SECONDS)
|
||||
cell.charge -= cell.maxcharge*celluse
|
||||
return 1
|
||||
return TRUE
|
||||
|
||||
/obj/machinery/power/apc/proc/toggle_breaker()
|
||||
if(!is_operational() || failure_timer)
|
||||
@@ -1486,6 +1496,8 @@
|
||||
|
||||
/obj/machinery/power/apc/proc/set_nightshift(on)
|
||||
set waitfor = FALSE
|
||||
if(nightshift_lights == on)
|
||||
return
|
||||
nightshift_lights = on
|
||||
for(var/obj/machinery/light/L in area)
|
||||
if(L.nightshift_allowed)
|
||||
@@ -1500,6 +1512,18 @@
|
||||
L.update(FALSE)
|
||||
CHECK_TICK
|
||||
|
||||
/obj/machinery/power/apc/proc/update_nightshift_auth_requirement()
|
||||
nightshift_requires_auth = nightshift_toggle_requires_auth()
|
||||
|
||||
/obj/machinery/power/apc/proc/nightshift_toggle_requires_auth()
|
||||
if(!area)
|
||||
return FALSE
|
||||
var/configured_level = CONFIG_GET(number/night_shift_public_areas_only)
|
||||
var/our_level = area.nightshift_public_area
|
||||
var/public_requires_auth = CONFIG_GET(flag/nightshift_toggle_public_requires_auth)
|
||||
var/normal_requires_auth = CONFIG_GET(flag/nightshift_toggle_requires_auth)
|
||||
return (configured_level && our_level && ((our_level <= configured_level)? public_requires_auth : normal_requires_auth))
|
||||
|
||||
#undef UPSTATE_CELL_IN
|
||||
#undef UPSTATE_OPENED1
|
||||
#undef UPSTATE_OPENED2
|
||||
|
||||
Reference in New Issue